OpenVMS VMS72_PCSI-V0101 VAX V7.2 PCSI ECO Summary
TITLE: OpenVMS VMS72_PCSI-V0101 VAX V7.2 PCSI ECO Summary
New Kit Date : 24-APR-2001
Modification Date: Not Applicable
Modification Type: Updated Kit Supersedes VMS72_PCSI-V0100
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
For OpenVMS savesets, the name of the compressed saveset
file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or
kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS
saveset is copied to your system, expand the compressed
saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe.
For PCSI files, once the PCSI file is copied to your system,
rename the PCSI file to kitname-dcx_axpexe.pcsi, then it can
be expanded by typing RUN kitname-dcx_axpexe.pcsi. The resultant
file will be the PCSI installation file which can be used to install
the ECO.
Copyright (c) Compaq Computer Corporation 2001. All rights reserved.
OP/SYS: OpenVMS VAX
COMPONENT: PCSI
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: VMS72_PCSI-V0101
DEC-VAXVMS-VMS72_PCSI-V0101--4.PCSI
ECO Kits Superseded by This ECO Kit: DEC-VAXVMS-VMS72_PCSI-V0100--4.PCSI
ECO Kit Approximate Size: 1824 Blocks
Kit Applies To: OpenVMS VAX V7.2
System/Cluster Reboot Necessary: No
Rolling Re-boot Supported: Not Applicable
Installation Rating: INSTALL_1
1 - To be installed by all customers.
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for PCSI on VAX V7.2. The new kit addresses
the following problems:
PROBLEMS ADDRESSED IN VMS72_PCSI-V0101 KIT:
o When installing FORTRAN and FORRTL products, the system hangs
if both products are selected for installation at the same
time.
Images Affected: [SYSLIB]PCSI$SHR.EXE
[SYSEXE]PCSI$MAIN.EXE
o If the following PCSI steps are taken:
1. Install a FULL type product kit
2. Patch the FULL product with a PATCH type kit(s)
3. Install a PARTIAL type software product on top of the FULL
kit
then, two versions of the same FULL product are created and
patches are not transferred from the FULL product to the
PARTIAL product. This would eventually lead to an
un-repairable PCSI database corruption.
Images Affected: [SYSEXE]PCSI$MAIN.EXE
[SYSLIB]PCSI$SHR.EXE
o The following duplicate error messages reported by the PCSI
utility display during a product upgrade:
%PCSI-E-INSVOLSPC, insufficient space on volume DISK$ALPCSI_SYS
-PCSI-I-VOLSPC, 159261 required; 124344 available; -34917 net
Terminating is strongly recommended.
Do you want to terminate? [YES] no
%PCSI-E-INSVOLSPC, insufficient space on volume DISK$ALPCSI_SYS
-PCSI-I-VOLSPC, 159261 required; 124344 available; -34917 net
Terminating is strongly recommended.
Do you want to terminate? [YES] no
Images Affected: [SYSLIB]PCSI$SHR.EXE
o The reinstallation of a PARTIAL kit causes an ACCVIO. This
occurs when certain data is passed from one instance of the
PARTIAL product to another instance of the same product.
After the transfer, pointers to the originating data
structures are cleared. These pointers will be needed later.
When the PARTIAL kits are different, re-installation of
PARTIAL kit will not clear pointers.
Images Affected: [SYSLIB]PCSI$SHR.EXE
o When re-installing a product that has a library module in its
Product Description File (PDF), the PCSI utility terminates
with an ACCVIO error.
Images Affected: [SYSLIB]PCSI$SHR.EXE
[SYSEXE]PCSI$MAIN.EXE
o Changed the behavior of file conflict resolution between a
file from the kit being installed and a file with the same
name that has already been installed. Previously, when two
files had the same generation number, the PCSI utility would
retain the file already on the system disk. Now when there is
a tie, the file from the kit being installed replaces the file
previously installed.
Images Affected: [SYSLIB]PCSI$SHR.EXE
[SYSEXE]PCSI$MAIN.EXE
o When a PRODUCT RECONFIGURE command is executed and the
re-configured product has two or more patches applied to it,
the PCSI utility incorrectly marks the patches as removed.
This inconsistency can cause an ACCVIO on subsequent
operations.
Images Affected: [SYSLIB]PCSI$SHR.EXE
o When a FULL product kit replaces a file provided by another
product, or a PATCH product kit replaces a file provided by
its parent product or another patch, use of the IMAGE LIBRARY
option of the FILE statement in the PDF (Product Description
File) must be used consistently. For example, if one product
provides a file and places it in SYS$LIBRARY:IMAGELIB.OLB, but
another product replaces the file but does not specify that it
should also be placed in image library, then the installation
will fail with a %PCSI-E-PARUDF error message.
Images Affected: [SYSLIB]PCSI$SHR.EXE
o An attempt to upgrade a product and also apply a patch (or
ECO) kit to it in the same PRODUCT INSTALL opertion may fail
with the following error:
%PCSI-E-FAILCONF, ...
Images Affected: [SYSEXE]PCSI$MAIN.EXE
[SYSLIB]PCSI$SHR.EXE
o Installation of two or more patch kits that provide the same
file, and also update IMAGELIB.OLB with the file, may cause
the PCSI product database to be inconsistent if the patch kits
are installed out of order. Symptons include:
o Output from a PRODUCT SHOW OBJECT /FULL command shows that
all versions of the file are in conflict with one another
(i.e., no file in the set has a status of "OK").
o Output from a PRODUCT SHOW OBJECT /FULL command shows that
the owner of the file is one product and the owner of the
module in IMAGELIB.OLB is another product (or patch).
Images Affected: [SYSEXE]PCSI$MAIN.EXE
[SYSLIB]PCSI$SHR.EXE
o When a number of patch kits are installed in a descending
version sequence, and they contain files with IMAGE LIBRARY
attribute set, a PRODUCT SHOW OBJECT command will display all
the IMAGE LIBRARY files at conflict. This indicates incorrect
entries to the PCSI database and may cause some problems.
Images Affected: [SYSLIB]PCSI$SHR.EXE
INSTALLATION NOTES:
The system does not need to be rebooted after this kit is installed.
However, all processes will need to log out and then back in to use
the new PRODUCT command qualifiers and keywords.
All trademarks are the property of their respective owners.