OpenVMS VMS62TO71_PCSI-V0200 VAX V6.2 and V7.1 PCSI ECO Summary
TITLE: OpenVMS VMS62TO71_PCSI-V0200 VAX V6.2 and V7.1 PCSI ECO Summary
Modification Date: 03-MAY-2000
Modification Type: Updated Kit: Supersedes VMS62TO71_PCSI-V0100
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
For OpenVMS savesets, the name of the compressed saveset
file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or
kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS
saveset is copied to your system, expand the compressed
saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe.
For PCSI files, once the PCSI file is copied to your system,
rename the PCSI file to kitname-dcx_axpexe.pcsi, then it can
be expanded by typing RUN kitname-dcx_axpexe.pcsi. The resultant
file will be the PCSI installation file which can be used to install
the ECO.
Copyright (c) Compaq Computer Corporation 1998, 2000. All rights reserved.
OP/SYS: OpenVMS VAX
COMPONENT: PCSI
PCSI$MAIL.EXE
PCSI$SHR.EXE
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: VMS62TO71_PCSI-V0200
DEC-VAXVMS-VMS62TO71_PCSI-V0200--4.PCSI
ECO Kits Superseded by This ECO Kit: VMS62TO71_PCSI-V0100
ECO Kit Approximate Size: 1968 Blocks
Kit Applies To: OpenVMS VAX V6.2, V7.1
System/Cluster Reboot Necessary: No
Rolling Re-boot Supported: Not Applicable
Installation Rating: INSTALL_2
2 - To be installed on all systems running
the listed version(s) of OpenVMS and
using the following feature(s):
New PRODUCT command functionality
Layered product installation instructions
that require this remedial kit to be
installed as a prerequisite
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for PCSI on VAX V6.2 through V7.1.
New Functionality Included in VMS62TO71_PCSI-V0200:
o This remedial kit updates the POLYCENTER Software Installation
utility of OpenVMS, including associated command procedures
and help text. After installation, the POLYCENTER Software
Installation facility will be functionally equivalent to that
provided by OpenVMS V7.2. Changes include new PRODUCT
commands and qualifiers, improved display of output from
PRODUCT SHOW commands, features useful for product developers,
and several corrections for problems that have been fixed
since OpenVMS V7.2 was released.
After installaton of this remedial kit your system will use
the new features provided by this version of the POLYCENTER
Software Installation utility. If a layered product is
installed that makes use of this new functionality, then it
may not be possible to revert back to an older version of the
utility. This restriction occurs because there may be records
in the software product database that the older version of the
utility will not be able to interpret. This scenario may
occur after an OpenVMS upgrade to a version of OpenVMS prior
to V7.1-2. For example, this situation occurs if you:
1. Install this remedial kit on VMS V6.2 or V7.1
2. Install DWMOTIF V1.2-5
3. Upgrade to (or re-install) VMS V6.2 or V7.1
The upgrade to any of the versions listed in #3 above may fail
(or other PRODUCT command operations on the product database
may fail) with one of the following errors:
%SYSTEM-F-ACCVIO, access violation, ...
or
%PCSI-E-UNSDOCENC, unsupported product document encoding version
To prevent these failures after installing this remedial kit
and the DWMOTIF product (as in the example above), do the
following:
1. Remove DWMOTIF using the command:
$ PRODUCT REMOVE DWMOTIF
2. Upgrade to (or re-install) VMS V6.2 or V7.1
3. Re-install this remedial kit
4. Re-install DWMOTIF
This workaround is not needed if you are upgrading to OpenVMS
VAX V7.2. These releases already include the new features
provided by this remedial kit to eliminate this issue.
Images Affected:
- [SYSEXE]PCSI$MAIN.EXE
- [SYSLIB]PCSI$SHR.EXE
New Functionality Included in VMS62TO71_PCSI-V0100:
o This remedial kit updates the POLYCENTER Software Installation
utility of OpenVMS, including associated command procedures
and help text. After installation, the POLYCENTER Software
Installation facility will be functionally equivalent to that
provided by OpenVMS V7.2. Changes include new PRODUCT
commands and qualifiers, improved display of output from
PRODUCT SHOW commands, features useful for product developers,
and problem corrections.
After installation of this remedial kit your system will use
the new features provided by this version of the POLYCENTER
Software Installation utility. If a layered product is
installed that makes use of this new functionality, then it
may not be possible to revert back to an older version of the
utility. This restriction occurs because there may be records
in the software product database that the older version of the
utility will not be able to interpret. This scenario may
occur after an OpenVMS upgrade to a version of OpenVMS prior
to V7.1-2. For example, this situation occurs if you:
1. Install this remedial kit on VMS V6.2 or V7.1
2. Install DWMOTIF V1.2-5
3. Upgrade to (or re-install) VMS V6.2 or V7.1
The upgrade to any of the versions listed in #3 above may fail
(or other PRODUCT command operations on the product database
may fail) with one of the following errors:
SYSTEM-F-ACCVIO, access violation, ...
or
%PCSI-E-UNSDOCENC, unsupported product document encoding version
To prevent these failures after installing this remedial kit
and the DWMOTIF product (in the example above), do the
following:
1. Remove DWMOTIF using the command:
$ PRODUCT REMOVE DWMOTIF
2. Upgrade to (or re-install) VMS V6.2 or V7.1
3. Re-install this remedial kit
4. Re-install DWMOTIF
This workaround is not needed if you are upgrading to OpenVMS
VAX V7.2 because these releases already include the functionality
provided by this remedial kit.
INSTALLATION NOTES:
The system does not need to be rebooted after this kit is installed.
However, all processes will need to log out and then back in to use
the new PRODUCT command qualifiers and keywords.
All trademarks are the property of their respective owners.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
dec-vaxvms-vms62to71_pcsi-v0200--4.README
.CHKSUM
dec-vaxvms-vms62to71_pcsi-v0200--4.pcsi-dcx_vaxexe
vms62to71_pcsi-v0200.CVRLET_TXT-DCX_VAXEXE
vms62to71_pcsi-v0200.CVRLET_TXT
|