ACMS ACMSDAA_V5501012 ACMS V1.2A TP WEB Connector Gateway ECO Summary
TITLE: ACMS ACMSDAA_V5501012 ACMS V1.2A TP WEB Connector Gateway ECO Summary
Modification Date: 21-DEC-1999
Modification Type: New Kit
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
The name of the compressed file will be kit_name-dcx_vaxexe
for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
Once the file is copied to your system, it can be expanded
by typing RUN compressed_file. The resultant file will
be the OpenVMS saveset or PCSI installation file which
can be used to install the ECO.
Copyright (c) Compaq Computer Corporation 1999. All rights reserved.
PRODUCT: COMPAQ TP WEB Connector Gateway for ACMS
OP/SYS: OpenVMS VAX
COMPONENT: ACMSDA$GATEWAY.EXE
ACMSDA$MSG.EXE
ACMSDA$FORMS_MANAGER_SHR.EXE
ACMSDA$GATEWAY_SHR.EXE
ACMSDA$TSS_SHR.EXE
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: ACMSDAA_V55001012
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 567 Blocks
Kit Applies To: COMPAQ TP WEB Connector Gateway for ACMS V1.2A
OpenVMS VAX V5.5-2
System/Cluster Reboot Necessary: Yes
Rolling Re-boot Supported: Information Not Available
Installation Rating: INSTALL_UNKNOWN
Installation rating unknown
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for the ACMS TP Web Connector Gateway on ACMS V1.2A
on OpenVMS VAX V5.5-2. This kit addresses the following problems:
o SWLUP entries "call to close socket failed" that follow the
entry "unexpected deletion of client" are extraneous. These
errors are posted when a client connection is broken before a
sign out is done.
With TP Web Connector, once a client connection is established
in the web server, the information is cached and reused. The
connection remains open to the ACMS Gateway for up to 20 minutes
after the last access on that connection. Therefore, if the web
server is shutdown before the connections are closed, the SWLUP
log will record the error.
For each connection that was open prior to the shutdown of the
web server, the SWLUP log contained entries "unexpected deletion
of client" and "call to close socket failed". This ECO has
modified the code so that under this scenario, the SWLUP entry
will be limited to "unexpected deletion of client".
INSTALLATION NOTES:
The images in this kit will not take effect until the system is
rebooted. If there are other nodes in the VMScluster, they must
also be rebooted in order to make use of the new image(s).
All trademarks are the property of their respective owners.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
acmsdaa_v5501012.README
acmsdaa_v5501012.CHKSUM
acmsdaa_v5501012.CVRLET_TXT
acmsdaa_v5501012.a-dcx_vaxexe
acmsdaa_v5501012.CVRLET_TXT
|