OpenVMS VMS721H1_LAN-V0100 Alpha V7.2-1H1 LAN ECO Summary

TITLE: OpenVMS VMS721H1_LAN-V0100 Alpha V7.2-1H1 LAN ECO Summary New Kit Date : 19-FEB-2001 Modification Date: Not Applicable Modification Type: New Kit NOTE: An OpenVMS saveset or PCSI installation file is stored on the Internet in a self-expanding compressed file. For OpenVMS savesets, the name of the compressed saveset file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS saveset is copied to your system, expand the compressed saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe. For PCSI files, once the PCSI file is copied to your system, rename the PCSI file to kitname-dcx_axpexe.pcsi, then it can be expanded by typing RUN kitname-dcx_axpexe.pcsi. The resultant file will be the PCSI installation file which can be used to install the ECO. Copyright (c) Compaq Computer Corporation 2000. All rights reserved. OP/SYS: OpenVMS Alpha COMPONENT: LAN SOURCE: Compaq Computer Corporation ECO INFORMATION: ECO Kit Name: VMS721H1_LAN-V0100 DEC-AXPVMS-VMS721H1_LAN-V0100--4.PCSI ECO Kits Superseded by This ECO Kit: None ECO Kit Approximate Size: 6464 Blocks Kit Applies To: OpenVMS Alpha V7.2-1H1 System/Cluster Reboot Necessary: Yes Rolling Re-boot Supported: Yes Installation Rating: INSTALL_3 3 - To be installed on all systems running the listed versions of OpenVMS which are experiencing the problems described. Kit Dependencies: The following remedial kit(s) must be installed BEFORE installation of this kit: VMS721H1_UPDATE-V0300 In order to receive all the corrections listed in this kit, the following remedial kits should also be installed: None ECO KIT SUMMARY: An ECO kit exists for LAN on OpenVMS Alpha V7.2-1H1. This kit addresses the following problems: New Functionality Addressed In VMS721H1_LAN-V0100: o Compaq 3X-DAPBA-FA and Compaq 3X-DAPCA-FA ATM Adapters The 3X-DAPBA-FA and the 3X-DAPCA-FA are PCI based ATM adapters for Alpha based systems that provide high performance PCI-to-ATM capability. The 3X-DAPBA-FA adapter offers a 155 Mbps fiber connection; the 3X-DAPCA-FA adapter offers a 622 Mbps fiber connection. The datalink drivers for these adapters function in a new OpenVMS ATM environment. The new OpenVMS ATM environment is fully compatible with the existing legacy ATM support and allows both ATM environments to be configured on a single system. Additionally, the LANCP management interface is the same for both ATM environments. The following images/files support the new OpenVMS ATM environment: - [SYS$LDR]SYS$LAN.EXE - [SYS$LDR]SYS$LAN_CSMACD.EXE - [SYS$LDR]SYS$LAN_ATM.EXE - [SYS$LDR]SYS$LAN_ATM4.EXE (new) - [SYS$LDR]SYS$$ELDRIVER4.EXE (new) - [SYS$LDR]SYS$$HWDRIVER4.EXE (new) - [SYSEXE]SYS$CONFIG.DAT - [SYSEXE]LANCP.EXE - [SYSEXE]LANACP.EXE Requirements These adapters require a great deal of non-paged pool, and therefore, care should be taken when configuring them. The following restrictions apply to these adapters: + For each 3X-DAPBA-FA adapter, Compaq recommends increasing the SYSGEN parameter NPAGEVIR by 3000000. + For each 3X-DAPCA-FA adapter, Compaq recommends increasing NPAGEVIR by 6000000. To perform the above changes, add the ADD_NPAG_VIR parameter to MODPARAMS.DAT and then run AUTOGEN. For example, on a system with two 3X-DAPBA-FAs and one 3X-DAPCA-FA, you would add the following line to MODPARAMS.DAT: ADD_NPAG_VIR = 12000000 Restrictions The following restrictions apply to these adapters: + The adapter cannot be located on a PCI bus that is located behind a PCI-to-PCI bridge. Systems that have this configuration are the following: - Digital Personal AlphaWorkstation 600 - AlphaStation 1000A - COMPAQ Professional Workstation XP1000 - AlphaServer 2000 and 2100 + Classical IP is not supported with these new adapters. + SDA does not correctly identify these new ATM/FORE adapters. They are identified as "unknown adapters." This will be fixed in a subsequent support release. o Add support for unlimited chained transmit segments to ALPHA LAN drivers. Support has been added for unlimited chained transmit segments to LAN drivers. Support for this functionality is a performance enhancement for both IPv4 and IPv6. Images Affected: - [SYS$LDR]SYS$ERDRIVER.EXE - [SYS$LDR]SYS$EWDRIVER_DE500BA.EXE - [SYS$LDR]SYS$FXDRIVER.EXE - [SYS$LDR]SYS$ESDRIVER.EXE - [SYS$LDR]SYS$HCDRIVER.EXE - [SYS$LDR]SYS$HWDRIVER.EXE - [SYS$LDR]SYS$FADRIVER.EXE - [SYS$LDR]SYS$FCDRIVER.EXE - [SYS$LDR]SYS$FRDRIVER.EXE - [SYS$LDR]SYS$EXDRIVER.EXE - [SYS$LDR]SYS$FWDRIVER.EXE - [SYS$LDR]SYS$EWDRIVER.EXE o Add new functionality to support a gigabit Ethernet driver. Support for gigabit Ethernet drivers has been added. Images Affected: - [SYS$LDR]SYS$EW1000A.EXE - [SYS$LDR]SYS$LAN.EXE Problems Addressed In VMS721H1_LAN-V0100: o The PCI FDDI adapter (the DEFPA) halts with a fatal hardware error. On some systems, the PCI FDDI adapter (the DEFPA) halts with a fatal hardware error. When the driver attempts to restart the DEFPA, the driver detects either a parity error being reported by the DEFPA, or it detects a command failure, which prevents the driver from getting the DEFPA restarted successfully. Images Affected: - [SYS$LDR]SYS$FWDRIVER.EXE - [SYS$LDR]SYS$FRDRIVER.EXE - [SYS$LDR]SYS$FADRIVER.EXE o The line speed in the LDC may be set to either 4 or 16 megabits. The LAN Device Characteristics block (LDC) contains the device line speed, which applications may use to determine how fast the device is running. The Token Ring driver sets the line speed at 16, even if driver is set to 4 megabits. The change enables the driver to set the speed in the LDC to 4 or 16 megabits, whenever a new speed is determined. Images Affected: - [SYS$LDR]SYS$IWDRIVER.EXE - [SYS$LDR]SYS$IRDRIVER.EXE - [SYS$LDR]SYS$ICDRIVER.EXE o A multitude of data overruns causes very poor network performance when running from DE504 in ES40 to DE602 in GS160. Images Affected: - [SYS$LDR]SYS$EIDRIVER.EXE o A newly allocated buffer was put at the end of the buffer list. The system can crash with an INVEXCEPTN bugcheck. Images Affected: - [SYS$LDR]SYS$EWDRIVER.EXE - [SYS$LDR]SYS$ERDRIVER.EXE o The system can crash when an interrupt occurs after de-allocating the buffer. The crash occurs when the system attempts to make an interrupt trace entry. Images Affected: - [SYS$LDR]SYS$LAN.EXE - [SYS$LDR]SYS$LAN_CSMACD.EXE - [SYS$LDR]SYS$LAN_FDDI.EXE - [SYS$LDR]SYS$LAN_TR.EXE - [SYS$LDR]SYS$LAN_ATM.EXE - [SYS$LDR]SYS$EWDRIVER_DE500BA.EXE - [SYSEXE]LANCP.EXE o An INVEXCEPTN crash can occur when CSMACD executes an NCL script. Images Affected: - [SYS$LDR]SYS$EWDRIVER.EXE - [SYS$LDR]SYS$EWDRIVER_DE500BA.EXE - [SYS$LDR]SYS$EIDRIVER.EXE - [SYS$LDR]SYS$FWDRIVER.EXE - [SYS$LDR]SYS$FCDRIVER.EXE - [SYS$LDR]SYS$FRDRIVER.EXE - [SYS$LDR]SYS$FADRIVER.EXE - [SYS$LDR]SYS$EW1000A.EXE - [SYS$LDR]SYS$ELDRIVER.EXE - [SYSEXE]SYS$CONFIG.DAT - [SYSEXE]LANCP.EXE o The LAN device line speeds are displayed incorrectly with NISCACP. Images Affected: - [SYS$LDR]SYS$EWDRIVER.EXE - [SYS$LDR]SYS$EWDRIVER_DE500BA.EXE - [SYS$LDR]SYS$EIDRIVER.EXE - [SYS$LDR]SYS$FWDRIVER.EXE - [SYS$LDR]SYS$FCDRIVER.EXE - [SYS$LDR]SYS$FRDRIVER.EXE - [SYS$LDR]SYS$FADRIVER.EXE - [SYS$LDR]SYS$EW1000A.EXE - [SYS$LDR]SYS$ELDRIVER.EXE - [SYSEXE]SYS$CONFIG.DAT - [SYSEXE]LANCP.EXE o An INVEXCEPTN crash occurs in the SYS$EW1000A driver following a SET HOST/LAT. Images Affected: - [SYS$LDR]SYS$EWDRIVER.EXE - [SYS$LDR]SYS$EWDRIVER_DE500BA.EXE - [SYS$LDR]SYS$EIDRIVER.EXE - [SYS$LDR]SYS$FWDRIVER.EXE - [SYS$LDR]SYS$FCDRIVER.EXE - [SYS$LDR]SYS$FRDRIVER.EXE - [SYS$LDR]SYS$FADRIVER.EXE - [SYS$LDR]SYS$EW1000A.EXE - [SYS$LDR]SYS$ELDRIVER.EXE - [SYSEXE]SYS$CONFIG.DAT - [SYSEXE]LANCP.EXE o If the CLUSTER_CONFIG LANACP configuration process quota is exceeded, LAN devices cannot be enabled and the LAN process will abort. Images Affected: - [SYS$STARTUP]LAN$STARTUP.COM o DE425 does not function on systems that do not have mapping registers. Images Affected: - [SYS$LDR]SYS$ERDRIVER.EXE o Fix driver extension codes to facilitate accurate printing. In some instances, the extension codes were in conflict with the drivers' if-then-else implementations. Images Affected: - [SYSEXE]LANCP.EXE o Prevent SHOW_NODE from displaying error messages even after the specified node is found. Images Affected: - [SYSEXE]LANCP.EXE o A system can crash following the entry of a STOP/IP/ISA1 command from within the TCPWare management interface. Images Affected: - [SYS$LDR]SYS$EZDRIVER.EXE o On some systems, the DE600 may discard receive packets because it cannot get sufficient memory bandwidth to unload incoming receive packets. This results in poor system performance levels, e.g., network copies that take longer than expected and set host and TELNET sessions that see pauses, which are all caused by lost packets that force error recovery and re-transmission by individual applications. Images Affected: - [SYS$LDR]SYS$EIDRIVER.EXE o The transmit routine in the Gigabit Ethernet driver does not properly deal with buffers that cross more than two page boundaries. Data corruption may occur in the last 822 or less bytes of a large buffer and zeros may be transmitted instead of the correct data. Images Affected: - [SYS$LDR]SYS$EW1000A.EXE o A receive packet could occasionally be received into a buffer that the device had previously used, which results in pool corruption. Images Affected: - [SYS$LDR]SYS$EIDRIVER.EXE o A multi-segment transmit could transmit incorrect data to the destination or could result in a system machine check crash. Images Affected: - [SYS$LDR]SYS$EIDRIVER.EXE o Packets are left in the DE500BA receive ring and they do not get processed until another packet is received, which decreases performance. Images Affected: - [SYS$LDR]SYS$EWDRIVER_DE500BA.EXE o The LAN driver is called by a bugcheck to shutdown before it has run a unit init, so the LSD is zero. As a result, the LAN driver ACCVIOs. Images Affected: - [SYS$LDR]SYS$EIDRIVER.EXE INSTALLATION NOTES: The images in this kit will not take effect until the system is rebooted. If there are other nodes in the VMScluster, they must also be rebooted in order to make use of the new image(s). If it is not possible or convenient to reboot the entire cluster at this time, a rolling re-boot may be performed. Install this kit with the POLYCENTER Software installation utility by logging into the SYSTEM account, and typing the following at the DCL prompt: PRODUCT INSTALL VMS721H1_LAN /SOURCE=[location of Kit] The kit location may be a tape drive, CD, or a disk directory that contains the kit. Additional help on installing PCSI kits can be found by typing HELP PRODUCT INSTALL at the system prompt All trademarks are the property of their respective owners.



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

dec-axpvms-vms721h1_lan-v0100--4.README
dec-axpvms-vms721h1_lan-v0100--4.CHKSUM
dec-axpvms-vms721h1_lan-v0100--4.pcsi-dcx_axpexe
vms721h1_lan-v0100.CVRLET_TXT

privacy and legal statement