SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
OpenVMS VMS721H1_IPC-V0100 Alpha V7.2-1H1 IPC ECO Summary

TITLE: OpenVMS VMS721H1_IPC-V0100 Alpha V7.2-1H1 IPC ECO Summary New Kit Date : 09-MAY-2001 Modification Date: Not Applicable Modification Type: New Kit NOTE: An OpenVMS saveset or PCSI installation file is stored on the Internet in a self-expanding compressed file. For OpenVMS savesets, the name of the compressed saveset file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS saveset is copied to your system, expand the compressed saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe. For PCSI files, once the PCSI file is copied to your system, rename the PCSI file to kitname-dcx_axpexe.pcsi, then it can be expanded by typing RUN kitname-dcx_axpexe.pcsi. The resultant file will be the PCSI installation file which can be used to install the ECO. Copyright (c) Compaq Computer Corporation 2001. All rights reserved. OP/SYS: OpenVMS Alpha COMPONENT: IPC SOURCE: Compaq Computer Corporation ECO INFORMATION: ECO Kit Name: VMS721H1_IPC-V0100 DEC-AXPVMS-VMS721H1_IPC-V0100--4.PCSI ECO Kits Superseded by This ECO Kit: None ECO Kit Approximate Size: 752 Blocks Kit Applies To: OpenVMS Alpha V7.2-1H1 System/Cluster Reboot Necessary: Yes Rolling Re-boot Supported: Yes Installation Rating: INSTALL_1 1 - To be installed by all customers. Kit Dependencies: The following remedial kit(s) must be installed BEFORE installation of this kit: None In order to receive all the corrections listed in this kit, the following remedial kits should also be installed: None ECO KIT SUMMARY: An ECO kit exists for IPC on OpenVMS Alpha V7.2-1H1. This kit addresses the following problems: o If non-paged pool is depleted, an ACCVIO crash can occur when an application attempts to open an association through an IPC$K_FC_OPEN_ASSOCIATION call to the user mode in the system service routine SSRV$OpenAssociation. Crashdump Summary Information: ------------------------------ Bugcheck Type: INVEXCEPTN, Exception while above ASTDEL Current Process: ACME_SERVER Current Image: $6$DKA100:[SYS0.SYSCOMMON.] [SYSEXE]ACME_SERVER.EXE;1 Failing PC: FFFFFFFF.8035C204 SYS$IPC_SERVICES+04204 Failing PS: 00000000.00000803 Module: SYS$IPC_SERVICES (Link Date/Time: 31-MAR-2000 23:44:28.56) Offset: 00004204 Images Affected: [SYS$LDR]SYS$IPC_SERVICES.EXE o A CPUSPINWAIT crash occurs when a thread in execution tries to acquire the SCS SPINLOCK in routine SCATP$VCNX/VCNX$BRK_DEMULT_IPC_CONN. Crashdump Summary Information: ------------------------------ .literal Bugcheck Type: CPUSPINWAIT, CPU spinwait timer expired Current Process: REGISTRY_SERVER Current Image: $4$DKA0:[SYS0.][SYSEXE]REGISTRY$SERVER.EXE;4 Failing PC: FFFFFFFF.8007C3A4 SMP$TIMEOUT_C+00064 Failing PS: 28000000.00000803 Module: SYSTEM_SYNCHRONIZATION (Link Date/Time: 20-FEB-2000 02:49:52.50) Offset: 000003A4 Images Affected: [SYS$LDR]SYS$IPC_SERVICES.EXE o An INCONSTATE crash occurs in SYSIPC$SUBS/ipc$$remove_lcb due to a failed validity check. Crashdump Summary Information: ------------------------------ Bugcheck Type: INCONSTATE, Inconsistent I/O data base Current Process: TP_SERVER Current Image: TENOR$DRA0:[SYS0.SYSCOMMON.] [SYSEXE]TPSERV.EXE;2 Failing PC: FFFFFFFF.801DCDD0 SYS$IPC_SERVICES+14DD0 IPC$$REMOVE_LCB+002E0 Failing PS: 10000000.00000800 Module: SYS$IPC_SERVICES (Link Date/Time: 28-MAY-1999 23:24:12.96) Offset: 00014DD0 Images Affected: [SYS$LDR]SYS$IPC_SERVICES.EXE INSTALLATION NOTES: This kit requires a system reboot. Compaq strongly recommends that a reboot is performed immediately after kit installation to avoid system instability If you have other nodes in your OpenVMS cluster, they must also be rebooted in order to make use of the new image(s). If it is not possible or convenient to reboot the entire cluster at this time, a rolling re-boot may be performed. INSTALLATION INSTRUCTIONS: Install this kit with the POLYCENTER Software installation utility by logging into the SYSTEM account, and typing the following at the DCL prompt: PRODUCT INSTALL VMS721H1_IPC /SOURCE=[location of Kit] The kit location may be a tape drive, CD, or a disk directory that contains the kit. Additional help on installing PCSI kits can be found by typing HELP PRODUCT INSTALL at the system prompt All trademarks are the property of their respective owners.



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

dec-axpvms-vms721h1_ipc-v0100--4.README
dec-axpvms-vms721h1_ipc-v0100--4.CHKSUM
dec-axpvms-vms721h1_ipc-v0100--4.pcsi-dcx_axpexe
vms721h1_ipc-v0100.CVRLET_TXT

privacy and legal statement