OpenVMS VMS721H1_LOADSS-V0100 Alpha V7.2-1H1 SECURESHR ECO Summary
TITLE: OpenVMS VMS721H1_LOADSS-V0100 Alpha V7.2-1H1 SECURESHR ECO Summary
Modification Date: 13-NOV-2000
Modification Type: New Kit
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
For OpenVMS savesets, the name of the compressed saveset
file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or
kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS
saveset is copied to your system, expand the compressed
saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe.
For PCSI files, once the PCSI file is copied to your system,
rename the PCSI file to kitname-dcx_axpexe.pcsi, then it can
be expanded by typing RUN kitname-dcx_axpexe.pcsi. The resultant
file will be the PCSI installation file which can be used to install
the ECO.
Copyright (c) Compaq Computer Corporation 2000. All rights reserved.
OP/SYS: OpenVMS Alpha
COMPONENT: SECURESHR
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: VMS721H1_LOADSS-V0100
DEC-AXPVMS-VMS721H1_LOADSS-V0100--4.PCSI
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 288 Blocks
Kit Applies To: OpenVMS Alpha V7.2-1H1
System/Cluster Reboot Necessary: Yes
Rolling Re-boot Supported: Yes
Installation Rating: INSTALL_3
3 - To be installed on all systems running
the listed versions of OpenVMS which
are experiencing the problems described.
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
VMS721H1_UPDATE-V0300
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for SECURESHR on OpenVMS Alpha V7.2-1H1. This kit
addresses the following problems:
o When used by a user who has more than 124 rights identifiers,
a $PERSONA_CREATE requests fail with a BADBLOADR error.
Images Affected: [SYSLIB]SECURESHR.EXE
INSTALLATION NOTES:
The images in this kit will not take effect until the system is
rebooted. If there are other nodes in the VMScluster, they must
also be rebooted in order to make use of the new image(s).
If it is not possible or convenient to reboot the entire cluster at
this time, a rolling re-boot may be performed.
Install this kit with the POLYCENTER Software installation utility
by logging into the SYSTEM account, and typing the following at the
DCL prompt:
PRODUCT INSTALL VMS721H1_LOADSS /SOURCE=[location of Kit]
The kit location may be a tape drive, CD, or a disk directory that
contains the kit.
Additional help on installing PCSI kits can be found by typing
HELP PRODUCT INSTALL at the system prompt.
All trademarks are the property of their respective owners.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
dec-axpvms-vms721h1_loadss-v0100--4.README
dec-axpvms-vms721h1_loadss-v0100--4.CHKSUM
dec-axpvms-vms721h1_loadss-v0100--4.pcsi-dcx_axpexe
vms721h1_loadss-v0100.CVRLET_TXT
|