SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
OpenVMS VMS721H1_GRAPHICS-V0200 PowerStorm 300/350 Graphics ECO Summary

TITLE: OpenVMS VMS721H1_GRAPHICS-V0200 PowerStorm 300/350 Graphics ECO Summary New Kit Date : 05-MAR-2001 Modification Date: Not Applicable Modification Type: New Kit NOTE: An OpenVMS saveset or PCSI installation file is stored on the Internet in a self-expanding compressed file. For OpenVMS savesets, the name of the compressed saveset file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS saveset is copied to your system, expand the compressed saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe. For PCSI files, once the PCSI file is copied to your system, rename the PCSI file to kitname-dcx_axpexe.pcsi, then it can be expanded by typing RUN kitname-dcx_axpexe.pcsi. The resultant file will be the PCSI installation file which can be used to install the ECO. Copyright (c) Compaq Computer Corporation 2001. All rights reserved. OP/SYS: OpenVMS Alpha COMPONENT: Graphics SOURCE: Compaq Computer Corporation ECO INFORMATION: ECO Kit Name: VMS721H1_GRAPHICS-V0200 DEC-AXPVMS-VMS721H1_GRAPHICS-V0200--4.PCSI ECO Kits Superseded by This ECO Kit: None ECO Kit Approximate Size: 48160 Blocks Kit Applies To: OpenVMS Alpha V7.2-1H1 System/Cluster Reboot Necessary: Yes Rolling Re-boot Supported: Yes Installation Rating: INSTALL_2 2 - To be installed on all systems running the listed version(s) of OpenVMS and using the following feature(s): PBXGK-BB (ELSA GLoria Synergy-8) PBXGB-AA/CA (PowerStorm 3D30/4D20) Kit Dependencies: The following remedial kit(s) must be installed BEFORE installation of this kit: VMS721H1_UPDATE-V0300 VMS721H1_CPU2208-V0100 In order to receive all the corrections listed in this kit, the following remedial kits should also be installed: None ECO KIT SUMMARY: An ECO kit exists for PowerStorm 300/350 Graphics Controller support on OpenVMS Alpha V7.2-1H1. NEW FUNCTIONALITY ADDRESSED IN VMS721H1_GRAPHICS-V0200 KIT o PowerStorm 300/350 OpenVMS Graphics Support This kit provides support for the PowerStorm 300/350 Graphics adapter. Specific information about this support can be found in the P300_350_README file. This file is available in the following formats: o Text : P300_350_README.TXT o Acrobat Reader : P300_350_README.PDF o HTML : P300_350_README.HTML These files can be found at SYS$COMMON:[SYSHLP] NOTE: The PowerStorm 350 Graphics adapter is not currently supported on GS80, GS160 and GS320 systems. This information and functionality is included in this kit for Cluster Compatibility purposes for other machines that may be running VMS V7.2-1H1. o New ELSA GLoria Synergy DDX image A new device dependent X server image is provided to improve performance on EV6 (21264) based platforms containing ELSA GLoria Synergy graphics modules. A new procedure, SYS$MANAGER:DECW$DEVICE_CONFIG_P2.COM, is executed automatically during DECwindows startup. The new procedure will, on appropriate platforms, define a logical name that will redirect the server to use the new P2 device dependent X code, DECW$SERVER_DDX_P2.EXE. DECW$SERVER_DDX_GZ.EXE will continue to be used on older platforms containing ELSA GLoria Synergy graphics modules. Image(s) Affected: [SYSLIB]DECW$SERVER_DDX_P2.EXE P350 PROBLEMS ADDRESSED IN THE VMS721H1_GRAPHICS-V0200 KIT o With PowerStorm 300/350 graphics adapter(s), XGetImage on 8-plane visuals returned incorrect image data if the specified width was not a multiple of eight. Images Affected: [SYSLIB]DECW$SERVER_DDX_GB.EXE o On systems containing PowerStorm 300/350 graphics adapter(s), under certain conditions of 3D-application load, the address space of the DECwindows server would grow without limit, eventually exhausting the supply of page table entries (PTEs) resulting in a "not enough core" message being displayed. Images Affected: [SYSLIB]DECW$SERVER_DIX.EXE [SYSLIB]DECW$OPENGLPEERRI.EXE o Failure to create a 3D rendering context (e.g. due to resource exhaustion) is no longer a fatal server error with PowerStorm 300/350 adapter(s). Images Affected: [SYSLIB]DECW$OPENGLPEERRI.EXE [SYSLIB]DECW$SERVER_DDX_GB.EXE o PowerStorm 300/350 multi-head initialization problems on systems running at 667 MHz or faster have been solved. Images Affected: [SYS$LDR]SYS$GBDRIVER.EXE o With PowerStorm 300/350 adapter(s), the Store Colors operation on 8-plane PseudoColor windows could result in incorrect colors if the array of color values did not denote a consecutive range of pixel values. Images Affected: [SYS$LDR]SYS$GBDRIVER.EXE o The 1600 x 1200 @ 60 Hz video mode now works with PowerStorm 300/350 adapter(s). Images Affected: [SYS$LDR]SYS$GBDRIVER.EXE o Fast systems with PowerStorm 300/350 adapter(s) and large memory (667 MHz and above) sometimes crash when graphics operations are attempted while the system is already handling a heavy load of non-graphics I/O. Images Affected: [SYS$LDR]SYS$GBDRIVER.EXE o A system crash due to a page fault with the IPL set too high has been fixed in the PowerStorm 300/350 driver. Images Affected: [SYS$LDR]SYS$GBDRIVER.EXE o Xserver on Elsa Gloria Synergy crashes with the following message in DECW$SERVER_0_ERROR.LOG: Images Affected: [SYSLIB]DECW$SERVER_DDX_P2.EXE o Clipped text was incorrectly displayed with ELSA GLoria Synergy graphics modules. This occurred when scrolling horizontally within a text box (e.g., using Netscape). When enough text is typed into a text box to cause the field to scroll to the left, the text is corrupted or not displayed. Images Affected: [SYSLIB]DECW$SERVER_DDX_GZ.EXE o A 3rd party middleware product called GMS has missing text on the ELSA Gloria Synergy card. Images Affected: [SYSLIB]DECW$SERVER_DDX_GZ.EXE o An invalid exception ("INVEXCEPTN, Exception while above ASTDEL") bugcheck will sometimes occur while booting with an ELSA GLoria Synergy card installed. Images Affected: [SYS$LDR]SYS$GZDRIVER.EXE [SYS$LDR]SYS$GZVDRIVER.EXE o During startup, DECwindows prints an error saying that decw$fs-errors.log cannot be purged from SYS$SYSTEM. o A memory leak in the SYS$WSDRIVER (the pseudo display device driver) has been fixed. Images Affected: [SYS$LDR]SYS$WSDRIVER.EXE o The server crashed when no TCP/IP license was available. Images Affected: [SYSLIB]DECW$TRANSPORT_TCPIP.EXE o Multiple network interfaces are now supported. Images Affected: [SYSLIB]DECW$TRANSPORT_TCPIP.EXE o The following font server problems have been fixed: o The X11 server crashed with %SYSTEM-F-ASTFLT if given an unavailable Multiple network interfaces are now supported.server node. o The X11 server would hang if the font server aborted or restarted, or if there were significant network delays enroute to/from the font server. o The X11 server crashed if a client with an active font server request terminated. o Font server connection problems were not reported in the X11 server log. o The font server sometimes stopped accepting connections. o The font server crashed when clients using DHCP made requests. o Font server clients experienced problems if the font server was idle for approximately ten minutes or longer. o The font server could not be restarted until five minutes after it had terminated; it would report "address in use" for the TCP/IP socket. Images Affected: SYS$LIBRARY:DECW$SERVER_DIX.EXE SYS$SYSTEM:DECW$XFS.EXE SYS$SYSTEM:FSLSFONTS.EXE SYS$SYSTEM:FSINFO.EXE INSTALLATION NOTES: The images in this kit will not take effect until the system is rebooted. If you have other nodes in your OpenVMS cluster, they must also be rebooted in order to make use of the new image(s). If it is not possible or convenient to reboot the entire cluster at this time, a rolling re-boot may be performed. INSTALLATION INSTRUCTIONS: Install this kit with the POLYCENTER Software Installation utility by logging into the SYSTEM account, and typing the following at the DCL prompt: PRODUCT INSTALL VMS721H1_GRAPHICS /SOURCE=[location of Kit] The kit location may be a tape drive, CD, or a disk directory that contains the kit. Additional help on installing PCSI kits can be found by typing HELP PRODUCT INSTALL at the system prompt All trademarks are the property of their respective owners.



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

dec-axpvms-vms721h1_graphics-v0200--4.README
dec-axpvms-vms721h1_graphics-v0200--4.CHKSUM
dec-axpvms-vms721h1_graphics-v0200--4.pcsi-dcx_axpexe
vms721h1_graphics-v0200.CVRLET_TXT

privacy and legal statement