OpenVMS VMS721_LOADSS-V0100 Alpha V7.2-1 Secure Share ECO Summary
TITLE: OpenVMS VMS721_LOADSS-V0100 Alpha V7.2-1 Secure Share ECO Summary
Modification Date: 03-NOV-2000
Modification Type: New Kit
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
For OpenVMS savesets, the name of the compressed saveset
file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or
kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS
saveset is copied to your system, expand the compressed
saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe.
For PCSI files, once the PCSI file is copied to your system,
rename the PCSI file to kitname-dcx_axpexe.pcsi, then it can
be expanded by typing RUN kitname-dcx_axpexe.pcsi. The resultant
file will be the PCSI installation file which can be used to install
the ECO.
Copyright (c) Compaq Computer Corporation 2000. All rights reserved.
OP/SYS: OpenVMS Alpha
COMPONENT: SECURESHR
SECURESHRP
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: VMS721_LOADSS-V0100
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 560 Blocks
Kit Applies To: OpenVMS Alpha V7.2-1
System/Cluster Reboot Necessary: Yes
Rolling Re-boot Supported: Yes
Installation Rating: INSTALL_3
3 - To be installed on all systems running
the listed versions of OpenVMS which
are experiencing the problems described.
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
VMS721_UPDATE-V0100
VMS721_PCSI-V0100
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for Secure Share on OpenVMS Alpha V7.2-1. This kit
addresses the following problems:
o A call to $CREATE_USER_PROFILE can randomly return an
SS$_ACCVIO error for requests that do not pass a USERNAME
parameter.
Images Affected: [SYSLIB]SECURESHRP.EXE
o $PERSONA_CREATE requests for users with large numbers of
rights (greater than 124) would fail with a BADBLOADR error.
Images Affected: [SYSLIB]SECURESHR.EXE
INSTALLATION NOTES:
The images in this kit will not take effect until the system is
rebooted. If there are other nodes in the VMScluster, they must
also be rebooted in order to make use of the new image(s).
If it is not possible or convenient to reboot the entire cluster at
this time, a rolling re-boot may be performed.
All trademarks are the property of their respective owners.