OpenVMS VMS721_QMAN-V0100 Alpha V7.2-1 Queue Manager ECO Summary
TITLE: OpenVMS VMS721_QMAN-V0100 Alpha V7.2-1 Queue Manager ECO Summary
Modification Date: 16-NOV-2000
Modification Type: DOCUMENTATION: VMS721_PCSI-V0100 added as a
dependent prerequisite.
Modification Date: 15-NOV-2000
Modification Type: New Kit
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
For OpenVMS savesets, the name of the compressed saveset
file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or
kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS
saveset is copied to your system, expand the compressed
saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe.
For PCSI files, once the PCSI file is copied to your system,
rename the PCSI file to kitname-dcx_axpexe.pcsi, then it can
be expanded by typing RUN kitname-dcx_axpexe.pcsi. The resultant
file will be the PCSI installation file which can be used to install
the ECO.
Copyright (c) Compaq Computer Corporation 2000. All rights reserved.
OP/SYS: OpenVMS Alpha
COMPONENT: Queue Manager
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: VMS721_QMAN-V0100
DEC-AXPVMS-VMS721_QMAN-V0100--4.PCSI
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 1216 Blocks
Kit Applies To: OpenVMS Alpha V7.2-1
System/Cluster Reboot Necessary: Yes
Rolling Re-boot Supported: Yes
Installation Rating: INSTALL_3
3 - To be installed on all systems running
the listed versions of OpenVMS which
are experiencing the problems described.
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
VMS721_UPDATE-V0100
VMS721_PCSI-V0100
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for the Queue Manager and Job Controller on OpenVMS
Alpha V7.2-1. This kit addresses the following problems:
o The Queue Manager ACCVIOs following a $SUBMIT/USER command.
See partial error message below:
----------------------------------------------------------------
%SYSTEM-F-ACCVIO, access violation, reason mask=00, virtual
address=89A666CC, PC=88ABB2E7, PSL=0BC00004
----------------------------------------------------------------
%SYSTEM-F-ACCVIO, access violation, reason mask=00, virtual
address=83ADD7CC, PC
=83164AE7, PSL=0BC00004
%%%%%%%%%%% OPCOM 3-MAY-2000 10:39:53.18 %%%%%%%%%%%
Message from user JOB_CONTROL on AV7000
%JBC-E-QMANDEL, unexpected queue manager process termination
Images Affected: [SYSEXE]QMAN$QUEUE_MANAGER.EXE
o When an unprivileged user attempts to access a queue and is
denied access, the event is neither alarmed nor audited.
Images Affected: [SYSEXE]SUBMIT.EXE
o When submitting a job to a queue, there is an option to retain
the job in the batch queue for a specified time after its
completion. However, this SUBMIT/RETAIN=UNTIL command does
not function properly.
Images Affected: [SYSEXE]SUBMIT.EXE
o Batch jobs with no corresponding processes can exist on a
system.
Images Affected: [SYSEXE]JBC$JOB_CONTROL.EXE
INSTALLATION NOTES:
The images in this kit will not take effect until the system is
rebooted. If there are other nodes in the VMScluster, they must
also be rebooted in order to make use of the new image(s).
If it is not possible or convenient to reboot the entire cluster at
this time, a rolling re-boot may be performed.
Install this kit with the POLYCENTER Software installation utility
by logging into the SYSTEM account, and typing the following at the
DCL prompt:
PRODUCT INSTALL VMS721_QMAN /SOURCE=[location of Kit]
The kit location may be a tape drive, CD, or a disk directory that
contains the kit.
Additional help on installing PCSI kits can be found by typing
HELP PRODUCT INSTALL at the system prompt.
All trademarks are the property of their respective owners.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
dec-axpvms-vms721_qman-v0100--4.README
dec-axpvms-vms721_qman-v0100--4.CHKSUM
dec-axpvms-vms721_qman-v0100--4.pcsi-dcx_axpexe
vms721_qman-v0100.CVRLET_TXT
|