OpenVMS VMS721_MANAGE-V0100 Alpha V7.2-1 MANAGE ECO Summary
TITLE: OpenVMS VMS721_MANAGE-V0100 Alpha V7.2-1 MANAGE ECO Summary
New Kit Date : 12-MAR-2001
Modification Date: Not Applicable
Modification Type: New Kit
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
For OpenVMS savesets, the name of the compressed saveset
file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or
kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS
saveset is copied to your system, expand the compressed
saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe.
For PCSI files, once the PCSI file is copied to your system,
rename the PCSI file to kitname-dcx_axpexe.pcsi, then it can
be expanded by typing RUN kitname-dcx_axpexe.pcsi. The resultant
file will be the PCSI installation file which can be used to install
the ECO.
Copyright (c) Compaq Computer Corporation 2001. All rights reserved.
OP/SYS: OpenVMS Alpha V7.2-1
COMPONENT: MANAGE
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: VMS721_MANAGE-V0100
DEC-AXPVMS-VMS721_MANAGE-V0100--4.PCSI
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 384 Blocks
Kit Applies To: OpenVMS Alpha V7.2-1
System/Cluster Reboot Necessary: No
Rolling Re-boot Supported: Information Not Available
Installation Rating: INSTALL_3
3 - To be installed on all systems running
the listed versions of OpenVMS which
are experiencing the problems described.
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
VMS721_UPDATE-V0100
VMS721_PCSI-V0100
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for MANAGE on OpenVMS Alpha V7.2-1. This kit
addresses the following problems:
PROBLEMS ADDRESSED IN VMS721_MANAGE-V0100 KIT
o The SYSMAN security profile is supposed to be identical on all
nodes in a cluster that uses the same security environment.
However, users have noticed that SYSMAN may use the
authorization privileges from the UAF (use authorization file)
instead of the locally set privileges on SOME nodes.
Images Affected: [SYSLIB]SMI$SHR.EXE
INSTALLATION NOTES:
No reboot is necessary after successful installation of the kit.
INSTALLATION INSTRUCTIONS:
Install this kit with the POLYCENTER Software installation utility
by logging into the SYSTEM account, and typing the following at the
DCL prompt:
PRODUCT INSTALL VMS721_MANAGE /SOURCE=[location of Kit]
The kit location may be a tape drive, CD, or a disk directory that
contains the kit.
Additional help on installing PCSI kits can be found by typing
HELP PRODUCT INSTALL at the system prompt
All trademarks are the property of their respective owners.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
dec-axpvms-vms721_manage-v0100--4.README
dec-axpvms-vms721_manage-v0100--4.CHKSUM
dec-axpvms-vms721_manage-v0100--4.pcsi-dcx_axpexe
vms721_manage-v0100.CVRLET_TXT
|