PTP20A01INT Compaq Portable TP for Windows NT Intel V2.0A ECO Summary
TITLE: PTP20A01INT Compaq Portable TP for Windows NT Intel V2.0A ECO Summary
Copyright (c) Compaq Computer Corporation 1999. All rights reserved.
PRODUCT: Compaq Portable TP for Windows NT
OP/SYS: Windows NT Intel
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: PTP20A01INT
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 12068 Blocks (6.2 Mb)
Kit Applies To: Compaq Portable TP for Windows NT V2.0A
Windows NT V4.0 - Intel
System/Cluster Reboot Necessary: No
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
ECO KIT SUMMARY:
An ECO kit exists for Compaq Portable TP for Windows NT on
Windows NT Intel V4.0. This kit addresses the following problems:
o If the environment variable stdl_log_file is set
to an invalid value, i.e. the directory path is invalid, the
application could hang when trying to do logging.
o On WindowsNT, if error logging is done to the
Event Log, the translation of the runtime error codes could
fail. This would occur only if a previous installation of
Portable TP was manually uninstalled, and the uninstall utility
was not used.
INSTALLATION NOTES:
Installation of this kit requires that Portable TP Version 2.0A
for Windows NT be present on the system prior to installing the ECO.
This installation does not ask for any product install keys.
Copy the following product/platform specific executable to a clean
folder and run it.
e.g. Intel PC running Windows NT
>cd c:\clean-folder
>ptp20a01int.exe
After running the executable, go to the alpha32 directory and execute
Setup.exe.
Restrictions and Requirements:
* Installation of ECO kit will update all TPware Product Suite
products (Application Optimizer for Windows NT, Portable TP for
Windows NT, TP Desktop Connector & TP Web Connector) currently
installed on the system. It is not necessary to perform a
separate installation for each TPware product installed on the
system.
* After installing the ECO, if your application uses the Microsoft RPC
(msrpc) adapter, the DCE (dce) adapter, or the ACMS Gateway (acmsda)
adapter, you must recompile your task group specification (STDL file)
and relink with your client.
* Please refer to Release Notes for installation restrictions
and guidelines.
All trademarks are the property of their respective owners.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
ptp20a01int.README
ptp20a01int.CHKSUM
ptp20a01int.CVRLET_TXT
ptp20a01int.exe
ptp20a01int.CVRLET_TXT
|