SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
OpenVMS VAXCLD01_071 VAX V7.1 Analyze ECO Summary

NOTE: An OpenVMS saveset or PCSI installation file is stored on the Internet in a self-expanding compressed file. The name of the compressed file will be kit_name-dcx_vaxexe for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha. Once the file is copied to your system, it can be expanded by typing RUN compressed_file. The resultant file will be the OpenVMS saveset or PCSI installation file which can be used to install the ECO. Copyright (c) Digital Equipment Corporation 1998. All rights reserved. OP/SYS: DIGITAL OpenVMS VAX COMPONENT: ANALYZE.CLD SOURCE: Digital Equipment Corporation ECO INFORMATION: ECO Kit Name: VAXCLD01_071 ECO Kits Superseded by This ECO Kit: None ECO Kit Approximate Size: 126 Blocks Kit Applies To: OpenVMS VAX V7.1 System/Cluster Reboot Necessary: No Installation Rating: 3 - To be installed on all systems running the listed versions of OpenVMS which are experiencing the problems described. NOTE: In order to receive the full fixes listed in this kit, the following remedial kits also need to be installed: None ECO KIT SUMMARY: An ECO kit exists for ANALYZE.CLD on OpenVMS VAX V7.1. This kit addresses the following problems: o The command ANAL/AUDIT/SELECT=(PRIVILEGES_USED=OPER) fails with a syntax error on 'IMPERSONATE'. INSTALLATION NOTES: The system does not need to be rebooted after this ECO kit is installed. However, the following commands should be executed in order for all kit changes to take effect. o Issue the command: SET COMMAND SYS$UPDATE:ANALYZE.CLD o To make the change permanent for the entire system issue the command: SET COMMAND/TABLE=SYS$LIBRARY:DCLTABLES/ -



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

vaxcld01_071.README
vaxcld01_071.CHKSUM
vaxcld01_071.CVRLET_TXT
vaxcld01_071.a-dcx_vaxexe

privacy and legal statement