SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
OpenVMS VAXLAD01_070 OpenVMS VAX V7.0 LAD Drivers ECO Summary

NOTE: An OpenVMS saveset or PCSI installation file is stored on the Internet in a self-expanding compressed file. The name of the compressed file will be kit_name-dcx_vaxexe for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha. Once the file is copied to your system, it can be expanded by typing RUN compressed_file. The resultant file will be the OpenVMS saveset or PCSI installation file which can be used to install the ECO. Copyright (c) Digital Equipment Corporation 1998. All rights reserved. OP/SYS: OpenVMS VAX COMPONENTs: DADDRIVER (SYS$DADDRIVER.EXE) LADDRIVER (SYS$LADDRIVER.EXE) LASTDRIVER (SYS$LASTDRIVER.EXE) MADDRIVER (SYS$MADDRIVER.EXE) ESS$LASTCP.EXE ESS$LADCP.EXE ESS$LAST_STARTUP.COM ESS$STARTUP.COM SOURCE: Digital Equipment Corporation ECO INFORMATION: ECO Kit Name: VAXLAD01_070 ECO Kits Superseded by This ECO Kit: None ECO Kit Approximate Size: 408 Blocks Saveset A - 396 Blocks Kit Applies To: OpenVMS VAX V7.0 System/Cluster Reboot Necessary: Yes Rolling Re-boot Supported: Yes Installation Rating: 2 - To be installed on all systems running the listed version of OpenVMS and using the following feature: InfoServer Kit Dependencies: The following remedial kit(s) must be installed BEFORE installation of this kit: None In order to receive all the corrections listed in this kit, the following remedial kits should also be installed: None ECO KIT SUMMARY: An ECO kit exists for SYS$DADDRIVER, SYS$LADDRIVER, SYS$LASTDRIVER, and SYS$MADDRIVER on OpenVMS VAX V7.0. This kit addresses the following problems: PROBLEMS ADDRESSED IN VAXLAD01_070 KIT: o The occasional packet transmitted by EWDRIVER had a source address and protocol type of zeros, which are discarded by the receiver. The booting system then retransmitted the packet 3 seconds later. However, since it is handling only 10 packets per second, the system booted very slowly. o If LADDRIVER parses connection (or solicitation) messages that have the sign bit set in the service class (an invalid value), the OpenVMS system will crash with an INVEXCEPTN bugcheck. o LASTDRIVER/DADDRIVER/MADDRIVER fixes: 1. Typing a CTRL/Y at a certain instance could cause an IO$_PACKACK function to a MAD device to be canceled. The result could eventually be that the system crashes in I/O post processing. 2. LADCP BIND/UNIT=x will cause a duplicate UCB unit number to be generated if the unit number specified is greater then the seed unit number. This problem can happen for both DADDRIVER and MADDRIVER. o LASTDRIVER crashes when it receives a run message in circuit stalled. o When booting from a CD, the InfoServer client can't be started. o InfoServer Client STOP/START bugs were fixed. o The system crashes in LTDRIVER when SSB is deleted prematurely while an UNLOAD is in progress. o The LASTDRIVER image crashes when it receives an Advertisement (ADV) or Solicit (SOL) message with a negative message length. o An overrun error on magtape occurs if the record size is greater then 65024. o In the past, BIND/TAPE/NOPERMANENT "tape_service" created a MADx device UCB that could be deleted once the UCB reference count went to zero. Problems occurred when the UCB was deleted due to the use of the /NOPERMANENT qualifier, that is multivolume BACKUP. Note: A MAD device is a tape device that is attached to an InfoServer. INSTALLATION NOTES: The images in this kit will not take effect until the system is rebooted. If there are other nodes in the VMScluster, they must also be rebooted in order to make use of the new images. If it is not possible or convenient to reboot the entire cluster at



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

vaxlad01_070.README
vaxlad01_070.CHKSUM
vaxlad01_070.CVRLET_TXT
vaxlad01_070.a-dcx_vaxexe

privacy and legal statement