SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
OpenVMS ALPBASR02_061 Alpha V6.1 BASRTL ECO Summary

Copyright (c) Digital Equipment Corporation 1994, 1995. All rights reserved. OP/SYS: OpenVMS Alpha COMPONENT: BASIC Run-Time Library (BASRTL) SOURCE: Digital Equipment Corporation ECO INFORMATION: ECO Kit Name: ALPBASR02_061 ECO Kits Superseded by This ECO Kit: AXPBASR01_061 (AXPBASR) ECO Kit Approximate Size: 4215 Blocks Kit Applies To: OpenVMS Alpha V6.1, V6.1-1H1, V6.1-1H2 System Reboot Necessary: No NOTE: All corrections included in this ECO have been incorporated into OpenVMS Alpha V6.2. ECO KIT SUMMARY: An ECO kit exists for BASRTL on OpenVMS Alpha V6.1 through V6.1-1H2. This kit addresses the following problems: Problems addressed in the ALPBASR02_061 kit: o PRINT USING on SCALEd D-Float numbers would round incorrectly. o MAT INV could return an Access Violation (ACCVIO) error if malloc() failed. o Bad float values (dirty zeros) are reported as division by zero. Problems addressed in the AXPBASR01_061 kit: o In some situations, the information output by the traceback facility after a DEC BASIC program has executed an ON ERROR GOTO 0 statement, is different than that of a VAX BASIC program. This occurs when: o the program has an ON ERROR handler o the program generates an error o the program executes an ON ERROR GOTO 0 while processing this error For a DEC BASIC program, the traceback facility displays the listing line number of the ON ERROR GOTO 0 statement. Whereas for a VAX BASIC program, the listing line number where the error occurred is displayed. This problem has been corrected so that the traceback facility now displays the listing line number where the error occurred. Please note that in order to guarantee that the listing line number is correct, the DEC BASIC program must be compiled with the /NOOPTIMIZE qualifier. o Due to a problem in the DEC BASIC Run-Time Library, BASIC programs that contain GOSUB's in which errors are generated and handled (for example, FIND's or GET's on an indexed file) use progressively more memory as each error is handled. o In some cases when NUM1$ was passed a Double precision floating point number, NUM1$ would give an improper value in the last decimal position. As an example, the following code printed '.07000000000000001' instead of the correct value '.07': T = .07 PRINT NUM1$(T) o When a non-zero SCALE factor was used with either the STR$ or NUM$ function, the function returned incorrect results. o In some cases when PRINT USING is passed a Double precision floating point number and the scale factor is non-zero, the resulting value is not rounded. This problem has been corrected. o If your DEC BASIC application signals SS$_DEBUG to invoke the debugger, and the application is compiled and linked with /DEBUG but run with /NODEBUG, the debugger's invocation may fail with the %DEBUG-E-INTERR error. This problem has been corrected. INSTALLATION NOTES: The system does not need to be rebooted after this kit is installed. However, if you have other nodes in your OpenVMS VMScluster, they should be rebooted or you should install this kit on each system in order to make use of the new image(s).





Files on this server are as follows:

alpbasr02_061.README
alpbasr02_061.CHKSUM
alpbasr02_061.CVRLET_TXT
alpbasr02_061.a-dcx_axpexe

privacy and legal statement