MFCOBOL MFCE0140A Micro Focus COBOL Developer Suite V4.0A ECO Summary
Copyright (c) Digital Equipment Corporation 1996. All rights reserved.
PRODUCT: Micro Focus COBOL[TM] for DIGITAL UNIX[R]
OP/SYS: DIGITAL UNIX
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: MFCE0140A
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 36,180 Blocks
(18,524,160 Bytes)
Kit Applies To: Micro Focus COBOL V4.0A
DIGITAL UNIX V3.2 - V4.0
System/Cluster Reboot Necessary: No
ECO KIT SUMMARY:
An ECO kit exists for Micro Focus COBOL V4.0A on DIGITAL UNIX V3.2 through
V4.0. This kit addresses the following problems:
o NWB48485 The COMPUTE statement produces incorrect results with
.gnt code. The decimal point is misplaced one space
to the right.
Example:
COMPUTE SUM1 = (A1 + A2 + A3) / 60
where SUM is defined as PIC 9(11)V9(1) and
A1, A2, A3 are PIC 9(13)
Release Notes Information
The release notes for Micro Focus COBOL V4.0A-1 contain informa-
tion specific to the products on DIGITAL UNIX, including a summary
of known problems and restrictions.
INSTALLATION NOTES:
o Installing Micro Focus COBOL requires DIGITAL UNIX Version 3.2.
This version of the Micro Focus COBOL products has also been
tested with DIGITAL UNIX Version 4.0.
The distribution of the Micro Focus COBOL Developer Suite is pro-
vided in the form of an ECO kit. The product is provided complete
on the kit. The tar file of MFCE0140A.tar must be unpacked before
using the setld utility to install the kit. Be sure to use the
setld -d option to deinstall the product prior to the installation
of this version. The documentation within the unpacked tar file
includes this document, the Micro Focus COBOL Installation Guide
for DIGITAL UNIX, and the Micro Focus COBOL Product Release Notes.
The documentation is provided in POSTSCRIPT[R] and ASCII forms in
the following directory.
o The Micro Focus COBOL documentation and installation subsets
are in the directories:
/mfce0140a/documentation
/mfce0140a/kit
The Micro Focus COBOL Installation Guide for DIGITAL UNIX has
not been updated with this release. The guide remains accurate
with the exception of the new version numbers described within
the examples. The current subset directory for Micro Focus COBOL
Developer Suite is mfce0140a. The corresponding subset names are:
MFCBASE402, MFCDOC402, MFCMAN402.
[TM] Bookreader, DEC, DIGITAL, and the DIGITAL logo are trademarks of
Digital Equipment Corporation.
[R] Micro Focus is a registered trademark and Micro Focus COBOL,
Toolbox, Micro Focus Dialog System, Operating System Exten-
sions are trademarks of Micro Focus Limited.
[R] POSTSCRIPT is a registered trademark of Adobe Systems, Inc.
[R] UNIX is a registered trademark in the United States and other
countries licensed exclusively through X/Open Company Limited.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
mfce0140a.README
mfce0140a.CHKSUM
mfce0140a.CVRLET_TXT
mfce0140a.tar
|