TPDESK TPD3101INT TP Desktop Connector V3.1 WNT Intel ECO Summary
TITLE: TPDESK TPD3101INT TP Desktop Connector V3.1 WNT Intel ECO Summary
Modification Date: 28-APR-99
Modification Type: New Kit
Copyright (c) Compaq Computer Corporation 1999. All rights reserved.
PRODUCT: Digital TP Desktop Connector V3.1
Windows NT (Intel)
OP/SYS: Windows NT V3.11, V4.0
Windows 98
OpenVMS VAX V5.5-2 to V7.2
OpenVMS Alpha V6.1 to V7.2
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: TPD3101INT
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 13550 Blocks
TPD3101INT.EXE 13550 Blocks
Kit Applies To: TP Desktop Connector V3.1
Windows NT (Intel)
System/Cluster Reboot Necessary: Unknown
Rolling Re-boot Supported: Unknown
Installation Rating: INSTALL_Unknown
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for TP Desktop Connector V3.1 on Windows NT (Intel)
V4.0. This kit addresses the following problems:
o The TPware Add sample server code was not the same code that is in the
ACMSxp V3.1 NT kit.
o The STDL compiler returned an error if the full path name of the
STDL file to be compiled contained embedded spaces.
o When interfacing with ACMS, floating point numbers with a high degree
of precision were not correctly converted from OpenVMS format to Windows NT
format.
o The Output Adapter drop down list for the client builder utility did
not list the ACMS output adapter type.
o A client using the ACMS Desktop output adapter would spin if the TP
Desktop Connector Gateway was shut down or crashed while the client was
connected.
o Failure to define RPC_DEFAULT_ENTRY via an environment variable or the
TPware management utility caused the DEC NSID process to crash.
o If a user was a member of many Windows NT groups, the TPware management
GUI would fail to start.
o The MSRPC output adapter did not correctly handle the selection of
multiple servers with the same interface if one of the servers was down.
o Binding Timeout if enabled did not work.
o Installing the Digital TP Desktop Connector and Digital Portable TP or
Digital Application Optimizer caused the Digtal TP Desktop Connector to
fail at runtime.
o The STDL compiler allowed numeric characters as the first character in an
STDL '#include' preprocessor directive statement.
o The STDL compiler truncated array names within records that exceeded 25
characters in length.
o The Java client make file(s) provided in this ECO kit is different from
the previous kit. If you are using the Java sample client(s), you should
copy the new make file from the appropriate sample directory into your
working directory.
o TP Desktop Connector Client Services on OpenVMS:
There was a problem with the OpenVMS client library files for the Alpha
platform. In error, VAX versions of the files were provided instead of
Alpha versions. This ECO kit includes the correct versions in the
vmsalpha directory generated by expanding the archive file as shown below.
The affected files are:
ACMSDI$CLIENT_OBJLIB.OLB
NET_DECNET.OBJ
NET_NETWARE.OBJ
NET_TCPIP.OBJ
Note, The condist kit was not affected by this problem. Those files are
correct.
INSTALLATION NOTES:
Installation of this kit requires that the January 1999 release of
the TPware Product Suite product(s) (Application Optimizer Version 2.0
for Windows NT, Portable TP Version 2.0 for Windows NT, TP Desktop
Connector Version 3.1, and TP Web Connector Version 1.2) be present
on the system prior to installing the ECO.
This installation does not ask for any product install keys.
Copy the following product/platform specific executable to a clean
folder and run it.
e.g. Intel compatible PC running Windows NT
>cd c:\clean-folder
>tpd3101int.exe
After running the executable, go to the intel32 directory
and execute Setup.exe.
Restrictions and Requirements:
* Installation of ECO kit will update all TPware Product Suite
products (Application Optimizer for Windows NT, Portable TP for
Windows NT, TP Desktop Connector & TP Web Connector) currently
installed on the system. It is not necessary to perform a
separate installation for each TPware product installed on the
system.
* After installing the ECO, if your application uses the Microsoft RPC
(msrpc) adapter, the DCE (dce) adapter, or the ACMS Gateway (acmsda)
adapter, you must recompile your task group specification (STDL file)
and relink with your client. For further information about this
requirement, please send e-mail to engineering at tp@Compaq.com.
* Please refer to Release Notes for installation restrictions
and guidelines.
All trademarks are the property of their respective owners.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
tpd3101int.README
tpd3101int.CHKSUM
tpd3101int.CVRLET_TXT
tpd3101int.exe
tpd3101int.CVRLET_TXT
|