PW-NT PWNT41A_DNA4E01 DECnet PATHWORKS V4.1 for Windows NT ECO Summary
Copyright (c) Digital Equipment Corporation 1994.
All rights reserved.
PRODUCT: PATHWORKS V4.1 for Windows NT
COMPONENT: DECnet Drivers
OP/SYS: MS Windows NT
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: PWNT41A_DNA4E01
ECO Kits Superseded by This Kit: None
ECO Kit Approximate Size: 332 Blocks (self-extracting archive)
Kit Applies To: PATHWORKS V4.1 for Windows NT
System Reboot Necessary: YES
ECO KIT SUMMARY:
An ECO kit exists for DECnet drivers for PATHWORK V4.1 for Windows NT.
This kit addresses the following problems:
o A PATHWORKS for Windows NT system stops accepting incoming
LAN Manager connections over DECnet. A user on a PATHWORKS
V4.x client will see a "Server not listening" error, while
a PATHWORKS V5.0 client will get the error "Network path
not found". This problem is more likely to occur in a network
where there are duplicate node addresses.
o In some circumstances, when a PATHWORKS for Windows NT system
receives a badly formatted Ethernet packet, it will bring down
the circuit and you can no longer make DECnet connections.
To determine if this has happened, do a "ncp show known circuit"
command and see if the circuit state is off. If the state is off,
check the Event Viewer application log for the following event
from PATHWORKS Evl, " Event type 4.6, Verification reject".
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
pwnt41a_dna4e01.README
pwnt41a_dna4e01.CHKSUM
pwnt41a_dna4e01.zp2
|