X25ALP X25ALP_E02B011 X.25 for OpenVMS Alpha V7.1 ECO Summary
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
The name of the compressed file will be kit_name-dcx_vaxexe
for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
Once the file is copied to your system, it can be expanded
by typing RUN compressed_file. The resultant file will
be the OpenVMS saveset or PCSI installation file which
can be used to install the ECO.
Copyright (c) Digital Equipment Corporation 1998. All rights reserved.
Modification Date: 04-MAY-1998
Modification Type: New Kit
PRODUCT: X.25 for OpenVMS Alpha
COMPONENT: ZWDRIVER
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: X25ALP_E02B011
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 258 Blocks
Saveset A - 252 Blocks
Kit Applies To: X.25 for OpenVMS Alpha V1.1B
OpenVMS Alpha V7.0 and V7.1
System/Cluster Reboot Necessary: Yes
Rolling Re-boot Supported: Not Known
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for ZWDRIVERS in X.25 for OpenVMS Alpha V1.1B
on OpenVMS Alpha V7.0 through V7.1. This kit addresses the
following problems:
Problems Addressed in X25ALP_E02B011:
o Stop ZWDRIVER needlessly consuming large amounts CPU time on
AlphaServer 4000 family systems.
o On PBXDP boards with more than 2 ports, correctly report the
state of the modem control signals of ports above the first two.
(The previous driver incorrectly reported the state of modem
control signals for port 0 as the state of the modem control
signals for each of ports 0, 2, 4 and 6 AND reported the state
of the modem control signals for port 1 as the state of the
modem control signals for ports 1, 3, 5 and 7.)
o Ensure the state of the modem control signal DTR always is
preserved across modifications to the register which controls
DTR. Previously the board read the port register and
inadvertently changed bit settings when doing so. The change
corrects this situation for all ports on the PBXDP
synchronous communications card.
INSTALLATION NOTES:
The images in this kit will not take effect until the system is
rebooted. If there are other nodes in the VMScluster, they must
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
x25alp_e02b011.README
x25alp_e02b011.CHKSUM
x25alp_e02b011.CVRLET_TXT
x25alp_e02b011.a-dcx_axpexe
|