PLY_SCD VPSAGT_E04B021 PLY Scheduler Agent V2.1B VAX ECO Summary
Copyright (c) Digital Equipment Corporation 1995. All rights reserved.
PRODUCT: POLYCENTER Scheduler OpenVMS Agent
OP/SYS: OpenVMS VAX
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: VPSAGT_E04B021
ECO Kits Superseded by This ECO Kit: None
ECO Approximate Kit Size: 2180 Blocks
Kit Applies To: POLYCENTER Scheduler OpenVMS Agent V2.1B
OpenVMS VAX V5.5-2, V5.5-2H4,
V6.0, V6.1, V6.2
NOTE: This ECO is the complete POLYCENTER
Scheduler OpenVMS Agent V2.1B product.
POLYCENTER Scheduler OpenVMS Agent V2.1B
does not need to be installed prior
installing this ECO. However, a valid
license must be installed.
The product version will be V2.1B-4
after installing this ECO.
This release of the POLYCENTER Scheduler
Version 2.1B Agent for OpenVMS must be
used only in conjunction with POLYCENTER
Scheduler Version 2.1B or later. It also
must be used with POLYCENTER Scheduler
V3.0 servers.
System Reboot Necessary: No
ECO KIT SUMMARY:
An ECO kit exists for POLYCENTER Scheduler OpenVMS Agent V2.1B on
OpenVMS VAX V5.5-2 through V6.2. This kit addresses the following
problems:
Problems addressed in the VPSAGT_E04B021 kit:
o Changes have been made in the way that the agent stores username
and nodename information so that the POLYCENTER Scheduler OpenVMS
Agent V2.1B-04 will be compatible with POLYCENTER Scheduler V3.0
for Digital UNIX[R]. Username and nodename information will be
converted to uppercase before performing a comparison during a
proxy check.
NOTE: Since all username and nodename information will be
converted to uppercase before a proxy check, this version of
the POLYCENTER Scheduler OpenVMS Agent will be unable to
distinguish between different accounts that use the same
username but with different case letters. For example,
if there were two accounts, one "smith" and the other
"SMITH", a proxy check would succeed for both accounts.
Please refer to the Release Notes included with this ECO for
additional information.
INSTALLATION NOTES:
The system/cluster does not need to be rebooted after this kit is
installed. However, the POLYCENTER Scheduler OpenVMS Agent should be
shutdown and restarted in order for all kit changes to take effect.
NOTE: During the installation of this ECO, the following messages may
be received during the LINKing of NSCHED$AGENT.EXE.
Linking NSCHED$AGENT.EXE ...
%LINK-I-DATMISMCH, creation date of 29-APR-1993 00:31 in
shareable image SYS$COMMON:[SYSLIB]PPLRTL.EXE;1
differs from date of 9-MAR-1994 01:33 in shareable
image library SYS$COMMON:[SYSLIB]IMAGELIB.OLB;1
%LINK-I-DATMISMCH, creation date of 29-APR-1993 00:34 in
shareable image SYS$COMMON:[SYSLIB]SECURESHR.EXE;1
differs from date of 9-MAR-1994 01:36 in shareable
image library SYS$COMMON:[SYSLIB]IMAGELIB.OLB;1
These messages are informational only and may be ignored.
[R] UNIX is a registered trademark in the United States and other
countries, licensed exclusively through X/Open Company Ltd.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
vpsagt_e04b021.README
vpsagt_e04b021.CHKSUM
vpsagt_e04b021.CVRLET_TXT
vpsagt_e04b021.a-dcx_vaxexe
|