OpenVMS VMS72_PORTS-V0100 Alpha V7.2 SCS ECO Summary
TITLE: OpenVMS VMS72_PORTS-V0100 Alpha V7.2 SCS ECO Summary
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
The name of the compressed file will be kit_name-dcx_vaxexe
for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
Once the file is copied to your system, it can be expanded
by typing RUN compressed_file. The resultant file will
be the OpenVMS saveset or PCSI installation file which
can be used to install the ECO.
Copyright (c) Compaq Computer Corporation 1999. All rights reserved.
Modification Date: 10-AUG-1999
Modification Type: New Kit
PRODUCT: OpenVMS Alpha
COMPONENT: SYS$SCS.EXE (Cluster, DUDRIVER)
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: VMS72_PORTS-V0100
DEC-AXPVMS-VMS72_PORTS-V0100--4.PCSI
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 180 Blocks
Kit Applies To: OpenVMS Alpha V7.2
System/Cluster Reboot Necessary: Yes
Rolling Re-boot Supported: Yes
Installation Rating: INSTALL_2 - To be installed on all systems running
the listed version(s) of OpenVMS and
using the following feature(s):
OpenVMS Alpha Clusters
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
DEC-AXPVMS-VMS72_UPDATE-V0100--4.PCSI (VMS72_UPDATE-V0100)
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for SYS$SCS on OpenVMS Alpha V7.2. This kit addresses
the following problems:
Problems Addressed in the VMS72_PORTS-V0100 Kit:
o FAST_PATH RSPID=0 and "stale" CDRP in SCS$GL_RDT, SYS$DUDRIVER
INVEXCEPTN
The cluster-related problems that can occur are:
1. SYS$SCS FAST_PATH RSPID = 0: "STALE READ/WRITE DATA-CORRUPTION"
or SYS$DUDRIVER cancel-related INVEXCEPTN bugcheck
Incorrect SYS$SCS FAST_PATH Response-ID (RSPID) handling
results in:
1) RSPID=0 and
2) a "stale" CDRP in the Response-Descriptor-Table
(SCS$GL_RDT) index-0
RDT-scans on DU-connection-failover or DU-I/O "CANCELing" will
attempt to process the "stale" CDRP, with either of the
following results:
- SYS$DUDRIVER/DUTU$CANCEL (or DUTU$END_CANCEL) INVEXCEPTN
bugchecks or
- DATA-CORRUPTION due to re-issuing MSCP-I/O on "stale" CDRP
2. SCAN_RDT STALE-CDRP "RSPID" verification to avoid potential
DATA-CORRUPTION from "STALE" CDRPs
If an SCS system application (DUDRIVER) fails to de-allocate an
"RSPID", a "stale" CDRP pointer will be left in the RDT. A
check is added for "stale" CDRPs on RDT-scans, to avoid data
corruption due to unintended reprocessing of a recycled CDRP.
Images(s) affected:
- [SYS$LDR]SYS$SCS.EXE
INSTALLATION NOTES:
The images in this kit will not take effect until the system is
rebooted. If there are other nodes in the VMScluster, they must
also be rebooted in order to make use of the new image(s).
If it is not possible or convenient to reboot the entire cluster at
this time, a rolling re-boot may be performed.
All trademarks are the property of their respective owners.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
dec-axpvms-vms72_ports-v0100--4.README
dec-axpvms-vms72_ports-v0100--4.CHKSUM
dec-axpvms-vms72_ports-v0100--4.pcsi-dcx_axpexe
vms72_ports-v0100.CVRLET_TXT
|