OpenVMS VAXSYSL04_062 VAX V6.2 SET TIME/System Crash SYSLOA ECO Summary
TITLE: OpenVMS VAXSYSL04_062 VAX V6.2 SET TIME/System Crash SYSLOA ECO Summary
Modification Date: 15-JAN-99
Modification Type: Updated Kit: Supersedes VAXSYSL03_062
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
The name of the compressed file will be kit_name-dcx_vaxexe
for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
Once the file is copied to your system, it can be expanded
by typing RUN compressed_file. The resultant file will
be the OpenVMS saveset or PCSI installation file which
can be used to install the ECO.
Copyright (c) Compaq Computer Corporation 1998. All rights reserved.
PRODUCT: DIGITAL OpenVMS VAX
COMPONENT: SYSLOA Executables
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: VAXSYSL04_062
ECO Kits Superseded by This ECO Kit: VAXSYSL03_062
ECO Kit Approximate Size: 1152 Blocks
Kit Applies To: OpenVMS VAX V6.2
System/Cluster Reboot Necessary: Yes
Rolling Reboot Supported: Yes
Installation Rating: INSTALL_3
3 - To be installed on all systems running
the listed versions of OpenVMS which
are experiencing the problems described.
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for various SYSLOA images on OpenVMS VAX V6.2. This kit
addresses the following problems:
PROBLEMS ADDRESSED IN VAXSYSL04_062:
o Interrupt vectors are not set properly in Backplane
Interconnect-specific (BI-specific) System Control Block
(SCB) pages.
o A system crash, with a CPUSANITY or CPUSPINWAIT bugcheck, can
occur when the Interrupt Stack pointer is near or at a page
boundary. A system hang can also occur.
PROBLEMS ADDRESSED IN VAXSYSL03_062:
o "$ SET TIME" without a specific time has been known to cause
intermittent SS$_IVTIME (%SYSTEM-F-IVTIME, invalid time) errors
on VAX model 7000-600 multiprocessor (SMP) machines.
INSTALLATION NOTES:
The images in this kit will not take effect until the system is
rebooted.
If you have other nodes in your VMS cluster, they must also be
rebooted in order to make use of the new image(s). If it is not
possible or convenient to reboot the entire cluster at this time, a
rolling re-boot may be performed.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
vaxsysl04_062.README
vaxsysl04_062.CHKSUM
vaxsysl04_062.CVRLET_TXT
vaxsysl04_062.a-dcx_vaxexe
|