OpenVMS VAXSYSL02_2H455 VAX V5.5-2H4 SYSLOA/Error Formatter ECO Summary
TITLE: OpenVMS VAXSYSL02_2H455 VAX V5.5-2H4 SYSLOA/Error Formatter ECO Summary
Modification Date: 29-JUL-98
Modification Type: New Kit
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
The name of the compressed file will be kit_name-dcx_vaxexe
for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
Once the file is copied to your system, it can be expanded
by typing RUN compressed_file. The resultant file will
be the OpenVMS saveset or PCSI installation file which
can be used to install the ECO.
Copyright (c) Digital Equipment Corporation 1998. All rights reserved.
OP/SYS: OpenVMS VAX
COMPONENT: Error Formatter
SYSLOA
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: VAXSYSL02_2H455
ECO Kits Superseded by This ECO Kit: VAXSYSL18_U2055 (For OpenVMS
V5.5-2H4 *ONLY*)
ECO Kit Approximate Size: 2142 Blocks
Kit Applies To: OpenVMS VAX V5.5-2H4
System/Cluster Reboot Necessary: Yes
Rolling Re-boot Supported: Yes
Installation Rating: 3 - To be installed on all systems running
the listed versions of OpenVMS which
are experiencing the problems described.}
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for SYSLOA and the Error Formatter on OpenVMS VAX
V5.5-2H4. This kit addresses the following problems:
Problems addressed in VAXSYSL02_2H455:
o The VAXSYSL18_U2055 multi-version kit is being re-issued as
separate kits. If you have installed the VAXSYSL18_U2055
remedial kit you do not need to install this kit.
Problems addressed in VAXSYSL18_U2055 for OpenVMS VAX V5.5-2H4:
o Previous SYSLOA kits have been combined into one kit. All
the problem solutions that were in the kits superseded by
VAXSYSL18_U2055 are included in VAXSYSL18_U2055 and apply
to versions 5.5-2 and 5.5-2H4 of OpenVMS VAX.
NOTE: The following SYSLOA*.EXEs are included in this
ECO kit and are used with the CPU types shown:
SYSLOA1202 VAX 6000-500
SYSLOA1302 VAX 6000-600
SYSLOA1303 VAX 4000-100/100A/105A MicroVAX 3100-90/95
SYSLOA1701 VAX 7000/10000
SYSLOA420 MicroVAX 3100
SYSLOA440 VAXstation 4000-VLC MicroVAX 3100-30/40
SYSLOA46 VAXstation 4000-60 MicroVAX 3100-80
SYSLOA49 VAXstation 4000-90
SYSLOA43 VAXstation 3100 M76
SYSLOA43D VAXstation 3100 M76/GPX
SYSLOA43S VAXstation 3100 M76/SPX
SYSLOA43W VAXstation 3100 M76 (MONOCHROME)
SYSLOA9CC VAX 6000-200/300
SYSLOA9RR VAX 6000-400
*********************** WARNING ****************************
* *
* If you are going to install this ECO kit on a VAXstation *
* 4000 Model 60 or VAXstation 4000 Model 90 system that has *
* a TURBOchannel device installed *AND* is a member of a *
* VAXcluster, you *MUST* install CSCPAT_1045 on your *
* system either before or in the same installation session *
* with this ECO. If this ECO is installed on a *
* system that meets the requirements mentioned above, *
* the system will crash at boot time with an INVEXCEPTN *
* bugcheck at STACONFIG+578A if CSCPAT_1045 does not *
* exist on the system. *
* *
* If you install both kits during the same session, *
* Digital recommends that you do not reboot between the *
* application of the two ECO kits due to the probability *
* of a system bugcheck which causes an unbootable system *
* if only this ECO is installed. *
* *
* For more information, please see the following article: *
* *
* *OpenVMS] CSCPAT_1045 SYSGEN, STACONFIG And *
* TURBOchannel ECO Summary *
* *
**************************************************************
o ANALYZE/ERROR returns an ACCVIO while processing a memory error
packet.
o The VAXstation Model 90 hangs when the VME B board is accessed
after reset.
o ANALYZE/ERROR report does not call the VAXstation 4000-VLC and
MicroVAX 3100-30, -40 a KA45 as it should.
INSTALLATION NOTES:
The images in this kit will not take effect until the system is
rebooted. If there are other nodes in the VMScluster, they must
also be rebooted in order to make use of the new image(s).
If it is not possible or convenient to reboot the entire cluster at
this time, a rolling re-boot may be performed.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
vaxsysl02_2h455.README
vaxsysl02_2h455.CHKSUM
vaxsysl02_2h455.CVRLET_TXT
vaxsysl02_2h455.a-dcx_vaxexe
|