SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
OpenVMS VAXSYSB02_062 OpenVMS VAX V6.2 SYSTEM Components ECO Summary

NOTE: An OpenVMS saveset or PCSI installation file is stored on the Internet in a self-expanding compressed file. The name of the compressed file will be kit_name-dcx_vaxexe for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha. Once the file is copied to your system, it can be expanded by typing RUN compressed_file. The resultant file will be the OpenVMS saveset or PCSI installation file which can be used to install the ECO. Copyright (c) Digital Equipment Corporation 1998. All rights reserved. Modification Date: 15-JUN-1998 Modification Type: Updated ECO Kit - supersedes VAXSYSB01_062 OP/SYS: OpenVMS VAX COMPONENTs: EVENT_FLAGS_AND_ASTS LOGICAL_NAMES PRIMITIVE_IO SECURITY SYSDEVICE SYSLICENSE VAXCLUSTER_CACHE SOURCE: Digital Equipment Corporation ECO INFORMATION: ECO Kit Name: VAXSYSB02_062 ECO Kits Superseded by This ECO Kit: VAXSYSB01_062 VAXSYS12_062 VAXSYS09_062 VAXSYS07_062 VAXSYS03_062 VAXSYS02_062 ECO Kit Approximate Size: 336 Blocks Saveset A - 324 Blocks Kit Applies To: OpenVMS VAX V6.2 System/Cluster Reboot Necessary: Yes Rolling Re-boot Supported: Yes Installation Rating: 1 - To be installed on all systems running the listed version(s) of OpenVMS. Kit Dependencies: The following remedial kit(s) must be installed BEFORE installation of this kit: None In order to receive all the corrections listed in this kit, the following remedial kits should also be installed: None ECO KIT SUMMARY: An ECO kit exists for SYSTEM Components on OpenVMS VAX V6.2. This kit addresses the following problems: PROBLEMS ADDRESSED IN VAXSYSB02_062 KIT: o After installing the VAXSYSB01_062 remedial kit the system version was changed to X6ZF-D4N and the system time was wrong. This was due to the SYS.EXE image. This image is not needed in the kit and is being removed, along with other SYS images that have no ECO corrections against them. PROBLEMS ADDRESSED IN VAXSYSB01_062 KIT: o The AUDIT server runs into an access violation in kernel mode when it encounters an unknown security class. o A process may hang if the process is being deleted while VIOC is waiting for a CFCB lock. This process will not be deletable since an original I/O, that will never complete, is outstanding. o Customer code locks the ACL, reads their ACE, updates a count field, re-writes the ACE, and unlocks the ACL. However, the updates to the count get lost. PROBLEMS ADDRESSED IN VAXSYS12_062 KIT o A SSRVEXCEPT crash occurred early in the boot process. The Signal Array had an ACCVIO with the message code in the offending PC = EXE$WRTMAILBOX+00C1C and in the operand = EXE$DELMBX+006E4. PROBLEMS ADDRESSED IN VAXSYS09_062 KIT o System crashes with one of the following footprints: INCONSTATE SYS$VCC_NPRO+00009F04 INCONSTATE SYS$VCC_NPRO+00009F00 INCONSTATE VAXCLUSTER_CACHE+03EB18 PROBLEMS ADDRESSED IN VAXSYS07_062 KIT o Security auditing of AME applications crash the system with a bugcheck error of "SECAUDERR, Fatal error attempting to perform a security audit" PROBLEMS ADDRESSED IN VAXSYS03_062 KIT o Pool corruption when wait form services are used with common event flags. PROBLEMS ADDRESSED IN VAXSYS02_062 KIT o If the buffer overflows during a license check, the user will not be able to make further use of the particular product that was doing the license check until the process that got the buffer overflow error is stopped. If that product was OpenVMS, any process attempting to login would hang. INSTALLATION NOTES: The images in this kit will not take effect until the system is rebooted. If there are other nodes in the VMScluster, they must also be rebooted in order to make use of the new images. If it is not possible or convenient to reboot the entire cluster at



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

vaxsysb02_062.README
vaxsysb02_062.CHKSUM
vaxsysb02_062.CVRLET_TXT
vaxsysb02_062.a-dcx_vaxexe

privacy and legal statement