OpenVMS VAXSYS21_061 VAX V6.1 System Primitives ECO Summary
TITLE: OpenVMS VAXSYS21_061 VAX V6.1 System Primitives ECO Summary
Modification Date: 09-JUL-98
Modification Type: New Kit
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
The name of the compressed file will be kit_name-dcx_vaxexe
for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
Once the file is copied to your system, it can be expanded
by typing RUN compressed_file. The resultant file will
be the OpenVMS saveset or PCSI installation file which
can be used to install the ECO.
Copyright (c) Digital Equipment Corporation 1998. All rights reserved.
OP/SYS: DIGITAL OpenVMS VAX
COMPONENT: System Primitives
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: VAXSYS21_061
ECO Kits Superseded by This ECO Kit: VAXSYS08_062 (for OpenVMS
(VAX V6.1 *ONLY*)
ECO Kit Approximate Size: 162 Blocks
Kit Applies To: OpenVMS VAX V6.1
System/Cluster Reboot Necessary: Yes
Rolling Re-boot Supported: Yes
Installation Rating: 3 - To be installed on all systems running
the listed versions of OpenVMS which
are experiencing the problems described.
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for the System Primitives on OpenVMS VAX V6.1.
This kit addresses the following problems:
Problems Addressed in VAXSYS21_061:
o The VAXSYSA01_062 remedial kit made the VAXSYS08_062 kit obsolete.
The VAXSYS08_062 kit was a multi-version kit that contained fixes
for V6.1 as well as V6.2. The V6.1 images are being re-issued
in a single version kit.
Problems Addressed in VAXSYS08_062 for OpenVMS VAX V6.1:
o A system crash may occur due to corruption in R1.
INSTALLATION NOTES:
The images in this kit will not take effect until the system is
rebooted. If there are other nodes in the VMScluster, they must
also be rebooted in order to make use of the new image(s).
If it is not possible or convenient to reboot the entire cluster at
this time, a rolling re-boot may be performed.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
vaxsys21_061.README
vaxsys21_061.CHKSUM
vaxsys21_061.CVRLET_TXT
vaxsys21_061.a-dcx_vaxexe
|