OpenVMS VAXDRIV01_072 VAX V7.2 TUDRIVER/DUDRIVER ECO Summary
TITLE: OpenVMS VAXDRIV01_072 VAX V7.2 TUDRIVER/DUDRIVER ECO Summary
Modification Date: 22-NOV-2000
Modification Type: Corrected references to OpenVMS VAX V7.1 to read
V7.2.
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
For OpenVMS savesets, the name of the compressed saveset
file will be kit_name.a-dcx_vaxexe for OpenVMS VAX or
kit_name.a-dcx_axpexe for OpenVMS Alpha. Once the OpenVMS
saveset is copied to your system, expand the compressed
saveset by typing RUN kitname.dcx_vaxexe or kitname.dcx_alpexe.
For PCSI files, once the PCSI file is copied to your system,
rename the PCSI file to kitname-dcx_axpexe.pcsi, then it can
be expanded by typing RUN kitname-dcx_axpexe.pcsi. The resultant
file will be the PCSI installation file which can be used to install
the ECO.
Copyright (c) Compaq Computer Corporation 1999, 2000. All rights reserved.
OP/SYS: OpenVMS VAX
COMPONENT: DUDRIVER
TUDRIVER
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: VAXDRIV01_072
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 180 Blocks
Kit Applies To: OpenVMS VAX V7.2
System/Cluster Reboot Necessary: Yes
Rolling Re-boot Supported: Yes
Installation Rating: INSTALL_3
3 - To be installed on all systems running
the listed versions of OpenVMS which
are experiencing the problems described.
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for TUDRIVER and DUDRIVER on OpenVMS VAX V7.2.
This kit addresses the following problems:
o When initializing a FIBRECHANNEL (DG) device from a client, one
of the two following errors is returned to the user (disk only,
not tape):
1. INIT-F_DIAGPACK, disk is a diagnostic pack; or
2. INIT-W-NOBADDATA, bad block data not found on volume
Note that an INIT of the same devices succeeds on the server.
Image(s) affected: [SYS$LDR]SYS$DUDRIVER.EXE
INSTALLATION NOTES:
The images in this kit will not take effect until the system is
rebooted. If there are other nodes in the VMScluster, they must
also be rebooted in order to make use of the new image(s).
If it is not possible or convenient to reboot the entire cluster at
this time, a rolling re-boot may be performed.
All trademarks are the property of their respective owners.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
vaxdriv01_072.README
vaxdriv01_072.CHKSUM
vaxdriv01_072.CVRLET_TXT
vaxdriv01_072.a-dcx_vaxexe
vaxdriv01_072.CVRLET_TXT
|