OpenVMS VAXDDTM01_071 VAX V7.1 DDTM Transaction Services ECO Summary
TITLE: OpenVMS VAXDDTM01_071 VAX V7.1 DDTM Transaction Services ECO Summary
Modification Date: 05-AUG-1999
Modification Type: New Kit
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
The name of the compressed file will be kit_name-dcx_vaxexe
for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
Once the file is copied to your system, it can be expanded
by typing RUN compressed_file. The resultant file will
be the OpenVMS saveset or PCSI installation file which
can be used to install the ECO.
Copyright (c) Compaq Computer Corporation 1999. All rights reserved.
OP/SYS: OpenVMS VAX
COMPONENT: Transaction Services
DECdtm Startup
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: VAXDDTM01_071
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 216 Blocks
Kit Applies To: OpenVMS VAX V7.1
System/Cluster Reboot Necessary: Yes
Rolling Re-boot Supported: Yes
Installation Rating: INSTALL_3
3 - To be installed on all systems running
the listed versions of OpenVMS which
are experiencing the problems described.
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for DECnet Plus distributed transaction problems on
OpenVMS VAX V7.1. This kit addresses the following problems:
o ACMS SI, Rdb SQL and/or DECdtm $ADD_BRANCH(W) calls fail with
an IPC-E-BCKTRNSFAIL error. This problem occurs for DECnet
Plus, where a distributed transaction is being initiated.
DECdtm was passing a node name to DECnet Plus, requesting a
DECnet Plus equivalent node name.
Image Affected: [SYS$LDR]SYS$TRANSACTION_SERVICES.EXE
o A machine crash occurred with a SSRVEXCEPT error at
TPSERV+22800.
INSTALLATION NOTES:
The images in this kit will not take effect until the system is
rebooted. If there are other nodes in the VMScluster, they must
also be rebooted in order to make use of the new image(s).
If it is not possible or convenient to reboot the entire cluster at
this time, a rolling re-boot may be performed.
All trademarks are the property of their respective owners.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
vaxddtm01_071.README
vaxddtm01_071.CHKSUM
vaxddtm01_071.CVRLET_TXT
vaxddtm01_071.a-dcx_vaxexe
vaxddtm01_071.CVRLET_TXT
|