OpenVMS VAXCLIU03_070 VAX V7.0 SET/SHOW ECO Summary
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
The name of the compressed file will be kit_name-dcx_vaxexe
for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
Once the file is copied to your system, it can be expanded
by typing RUN compressed_file. The resultant file will
be the OpenVMS saveset or PCSI installation file which
can be used to install the ECO.
Copyright (c) Digital Equipment Corporation 1994, 1997. All rights reserved.
OP/SYS: OpenVMS VAX
COMPONENTS: CLIUTL - SET.EXE
SHOW.EXE
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: VAXCLIU03_070
ECO Kits Superseded by This ECO Kit: VAXCLIU02_070 (V7.0 Only)
VAXCLIU01_070 (V7.0 Only)
ECO Kit Approximate Size: 700 Blocks
Kit Applies To: OpenVMS VAX V7.0
System/Cluster Reboot Necessary: No
Installation Rating: 3 - To be installed on all systems running
the listed versions of OpenVMS which
are experiencing the problems described.
NOTE: In order to receive the full fixes listed in this kit,
the following remedial kits also need to be installed:
None
ECO KIT SUMMARY:
An ECO kit exists for the DCL commands 'SET' and 'SHOW' on OpenVMS
VAX V7.0. This kit addresses the following problems:
Problems Addressed in the VAXCLIU03_070 Kit:
o This problem was originally fixed in the VAXCLIU02_070 remedial kit,
but this is a new problem that has the same effect. This kit fixes
the new problem.
When doing a SHOW PROCESS /CONTINUOUS command in a constrained
working set, it is possible to get a PGFIPLHI bugcheck.
The problem occurs because a reference is made at elevated IPL, to
one of several data cells located in pageable memory.
Problems Addressed in the VAXCLIU01_070 Kit for OpenVMS VAX V7.0:
o A DCL 'SHOW PROCESS/CONTINUOUS' command can cause a system crash
if the process being shown has already been deleted.
o In V5.5, when LAT master was used to replace the old LTDRIVER, a
problem was found that might, in certain circumstances, cause a
fatal bugcheck. This occurred if the DCL commands
SET TERMINAL/PROTOCOL=DDCMP LTAn
or
SET TERMINAL/PROTOCOL=NONE LTAn
were used. Since DDCMP protocol has never been supported on LAT
ports, a decision was made to disable the use of these commands on
LAT ports. Since V5.5 shipped it has been found that many customers
have third-party software that does do DDCMP on LAT ports. This has
become a major customer satisfaction issue.
INSTALLATION NOTES:
The system does not need to be rebooted after this kit is installed.
However, if you have other nodes in your OpenVMS VMScluster, they should
be rebooted or you should install this kit on each system in order to
make use of the new image(s).
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
vaxcliu03_070.README
vaxcliu03_070.CHKSUM
vaxcliu03_070.CVRLET_TXT
vaxcliu03_070.a-dcx_vaxexe
|