SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
OpenVMS VAXBACK03_062 OpenVMS VAX V6.2 Backup Utility ECO Summary

TITLE: OpenVMS VAXBACK03_062 OpenVMS VAX V6.2 Backup Utility ECO Summary NOTE: An OpenVMS saveset or PCSI installation file is stored on the Internet in a self-expanding compressed file. The name of the compressed file will be kit_name-dcx_vaxexe for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha. Once the file is copied to your system, it can be expanded by typing RUN compressed_file. The resultant file will be the OpenVMS saveset or PCSI installation file which can be used to install the ECO. *OpenVMS] VAXBACK03_062 OpenVMS VAX V6.2 Backup Utility ECO Summary Copyright (c) Compaq Computer Corporation 1998. All rights reserved. Modification Date: 18-MAR-1999 Modification Type: Article Updated as VAXMOUN03_062 is Now Available Modification Date: 02-DEC-1998 Modification Type: Updated Article to list the dependent ECO VAXMOUN03_062 as unavailable until a later date. Modification Date: 14-JAN-1999 Modification Type: Updated to indicate that the VAXY2K02_062 kit must be installed before installation of this kit. Modification Date: 20-NOV-1998 Modification Type: Updated ECO Kit - Supersedes VAXDISM01_062 NOTE: The documentation for this kit calls out a dependency on the VAXMOUN03_062 remedial kit. This MOUNT kit is not currently available but will be available at a future date. OP/SYS: DIGITAL OpenVMS VAX COMPONENT: BACKUP Utility SOURCE: Compaq Computer Corporation ECO INFORMATION: ECO Kit Name: VAXBACK03_062 ECO Kits Superseded by This ECO Kit: VAXBACK02_062 VAXBACK01_062 ECO Kit Approximate Size: 414 Blocks Kit Applies To: OpenVMS VAX V6.2 System/Cluster Reboot Necessary: No Rolling Re-boot Supported: Not Applicable Installation Rating: INSTALL_3 3 - To be installed on all systems running the listed versions of OpenVMS which are experiencing the problems described. Kit Dependencies: The following remedial kit(s) must be installed BEFORE installation of this kit: VAXY2K02_062 In order to receive all the corrections listed in this kit, the following remedial kits should also be installed: VAXSYSA02_062 VAXMTAA03_062 VAXDISM02_062 VAXINIT01_062 VAXMOUN03_062 ECO KIT SUMMARY: An ECO kit exists for BACKUP on OpenVMS VAX V6.2. This kit addresses the following problems: Problems Addressed in VAXBACK03_062: o A possible system crash occurs during Host Based RAID Unbinds with MME code enabled. A mailbox read synchronization problem causes the crash. This problem only occurs when a host-based RAID UNBIND command is done while an MME-based application is running. The problem may occur in several different code areas of the operating system. In order get eliminate all known instances of this problem, the following remedial kits (or their supersedants) will also need to be installed: VAXSYSA02_062 VAXMTAA03_062 VAXDISM02_062 VAXINIT01_062 VAXMOUN03_062 o A process using MME could potentially "miss" the VOL1 label on a tape. Also, a process could "hang" trying to send a message to the MME process. Problems Addressed in VAXBACK02_062: o The VAXBACK01_062 remedial kit should have included the BACKUP.CLD file to update DCLTABLES.EXE. After installing the VAXBACK01_062 kit, users saw error messages due to a missing /NO_INCREMENTAL qualifier. If systems in the cluster utilize different DCLTABLES, even if booting from a common system disk, this kit must be installed on those systems to update the DCLTABLES.EXE. Problems Addressed in VAXBACK01_062: o Incremental restores may get an INCDELERR error message and loop continuously when attempting to perform a directory tree delete on a specific DIR filespec. The following text is an example of the message syntax: %BACKUP-E-INCDELERR, error deleting $4$DUA153:[GHONEY.WINDATA.NETSCAPE.CACHE]CACHE.DIR;1 -SYSTEM-W-NOSUCHFILE, no such file o A possible ACCVIO (access violation) can occur when backing up volume sets, particularly individual relative volumes. o A possible loss of device cacheability when volume labels are overwritten could occur. Tape subsystems behave differently. Re-initializing a tape device cache value on volume switches may result in the loss of characteristic. The type of tape subsystem and it's stickiness of characteristic aggravates the problem. o One cannot append to a non-expired tape on saveset appends when using the /EXACT_LABEL qualifier. Tape_expiration logic has a check specifically for the (/EXACT_LABEL) qualifier. o BACKUP may invoke a Restart operation during a network RESTORE operation when the link breaks. BACKUP was treating the network saveset read as if it were a tape device. o A new qualifier was added to invoke pre-OpenVMS V6.2 /SINCE behavior. After enhancements to INCREMENTAL restores was done, feedback from customers and Customer Support Centers (CSCs) indicated that not everyone was completely pleased with the new /SINCE behavior. Old style (pre-OpenVMS V6.2) /SINCE behavior can be invoked by adding the new /NO_INCREMENTAL qualifier to the BACKUP command line. Note that this change was implemented differently in OpenVMS V7.1. Check the OpenVMS V7.1 release notes for that implementation. o After installing VAXMOUN02_062, BACKUP/NOASSIST no longer works. However, BACKUP/ASSIST works fine. INSTALLATION NOTES: The system does not need to be rebooted after this kit is installed. However, if the system is a member of a VMScluster, the other cluster members should be rebooted or this kit should be installed on each system in order to make use of the new image(s).



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

vaxback03_062.README
vaxback03_062.CHKSUM
vaxback03_062.CVRLET_TXT
vaxback03_062.a-dcx_vaxexe

privacy and legal statement