SNADW_TE SNADWTE_E01021 DECwindows SNA Terminal Emulator V2.1 ECO Summary
TITLE: SNADW_TE SNADWTE_E01021 DECwindows SNA Terminal Emulator V2.1 ECO Summary
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
The name of the compressed file will be kit_name-dcx_vaxexe
for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
Once the file is copied to your system, it can be expanded
by typing RUN compressed_file. The resultant file will
be the OpenVMS saveset or PCSI installation file which
can be used to install the ECO.
Copyright (c) Compaq Computer Corporation 1999. All rights reserved.
Modification Date: 16-Aug-1999
Modification Type: New Kit
PRODUCT: DECwindows SNA 3270 Terminal Emulator V2.1
OP/SYS: OpenVMS VAX
OpenVMS Alpha
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: SNADWTE_E01021
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 4590 Blocks
Saveset A - 4590 Blocks
Kit Applies To: DECwindows SNA 3270 Terminal Emulator V2.1
OpenVMS VAX V6.2, V6.2-0HF, V7.0, V7.1, and
V7.2
OpenVMS Alpha V6.2, V6.2-1H1, V6.2-1H2, V6.2-1H3,
V7.0, V7.1, V7.1-1H1, V7.1-1H2, and
V7.2
System/Cluster Reboot Necessary: No
ECO KIT SUMMARY:
An ECO kit exists for DECwindows SNA Terminal Emulator for OpenVMS V2.1
on OpenVMS V6.2 through V7.2.
Problems addressed in the SNADWTE_E01021 kit:
o Access Violation After SNALU62$DEACTIVATESESSION Issued
An ACCVIO would occur when the application tries to perform a
reconnect, for example, when the remote IBM becomes unavailable.
This would occur while using VMS/SNA as a gateway. It was
caused by the session block no longer being available or the
receive buffer having been deallocated.
Please note that the above title in the Release Notes should read
"Access violation after an attempt to reconnect". This will be
corrected in the next release.
o Connecting With The TCP Transport Would Fail
As a connection is being established, the sequence of transports
(default order is Local, DECnet and TCP) is tried. If one
transport fails, the subsequent transports would also fail.
This problem has been corrected.
o Isolated Pacing Response (IPR) Not Being Processed Would Cause Hang
When an IPR was received, and there are no receives outstanding,
the pacing state was not being set properly. This led to a hang
in the application after the pacing window was exhausted.
o Added Support For The Local Transport On The OpenVMS Alpha Platform
This will enable local users to connect to Compaq SNA Server
without using a network connection. This is similar to OpenVMS
VAX local users connections to VMS/SNA.
Example: $SET HOST/SNA 0.
o Transmit Byte Count Exceeds Buffer Length Error
Fixed a problem where the connection failed to a gateway because
the terminal ID was longer than 32 bytes. The following error
was returned:
%SNA-E-INVTRMPAR, invalid authterm parameter
-SNA-E-LENTOOLON, transmit byte count exceeds buffer length
o TE Crashed When The Shift Key And Any Alphanumeric Key Was Pressed
This was due to an DECC compiler problem. This problem has been
corrected.
INSTALLATION NOTES:
This ECO kit is installed with the VMSINSTAL command procedure.
After the installation is completed the product should be restarted
per the User's Guide installation instructions, to make the new
software active.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
snadwte_e01021.README
.CHKSUM
snadwte_e01021.a-dcx_axpexe
snadwte_e01021.a-dcx_vaxexe
snadwte_e01021.CVRLET_TXT
|