SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
DSPI SNA3270_E02016 Data Stream Prog. Interface V1.6 ECO Summary

TITLE: DSPI SNA3270_E02016 Data Stream Prog. Interface V1.6 ECO Summary NOTE: An OpenVMS saveset or PCSI installation file is stored on the Internet in a self-expanding compressed file. The name of the compressed file will be kit_name-dcx_vaxexe for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha. Once the file is copied to your system, it can be expanded by typing RUN compressed_file. The resultant file will be the OpenVMS saveset or PCSI installation file which can be used to install the ECO. Copyright (c) Compaq Computer Corporation 1999. All rights reserved. Modification Date: 17-AUG-1999 Modification Type: Updated Kit Supersedes SNA3270_E01016 PRODUCT: DECnet/SNA Data Stream Programming Interface for OpenVMS, V1.6 OP/SYS: OpenVMS Alpha V6.2, V6.2-1H1, V6.2-1H2, V6.2-1H3 V7.0, V7.1, V7.1-1H1, V7.1-1H2, V7.2 OpenVMS VAX V6.2, V6.2-0HF, V7.0, V7.1, V7.2 SOURCE: Compaq Computer Corporation ECO INFORMATION: ECO Kit Name: SNA3270_E02016 ECO Kits Superseded by This ECO Kit: SNA3270_E01016 ECO Kit Approximate Size: 6066 Blocks Kit Applies To: DECnet/SNA Data Stream Programming Interface for OpenVMS V1.6 System/Cluster Reboot Necessary: No Installation Rating: INSTALL_UNKNOWN This information is not available. Kit Dependencies: The following remedial kit(s) must be installed BEFORE installation of this kit: None In order to receive all the corrections listed in this kit, the following remedial kits should also be installed: None ECO KIT SUMMARY: An ECO kit exists for SNA DSPI V1.6 on OpenVMS V6.2 through V7.2. Problems Addressed in the SNA3270_E02016 Kit: o Access violation after an attempt to reconnect An ACCVIO would occur when the application tries to perform a reconnect, for example, when the remote IBM becomes unavailable. This would occur while using VMS/SNA as a gateway. It was caused by the session block no longer being available or the receive buffer having been deallocated. o Connecting with the TCP Transport would fail As a connection is being established, the sequence of transports (default order is Local, DECnet and TCP) is tried. If one transport fails, the subsequent transports would also fail. This problem has been corrected. o Isolated Pacing Response (IPR) not being processed would cause hang When an IPR was received, and there are no receives outstanding, the pacing state was not being set properly. This led to a hang in the application after the pacing window was exhausted. o Added support for the Local transport on the OpenVMS Alpha platform Added support for the Local transport on the OpenVMS Alpha platform. This will enable local users to connect to Compaq SNA Server without using a network connection. This is similar to OpenVMS VAX local users connections to VMS/SNA. Example: $SET HOST/SNA 0. o Transmit byte count exceeds buffer length Fixed a problem where the connection failed to a gateway because the terminal ID was longer than 32 bytes. The following error was returned: %SNA-E-INVTRMPAR, invalid authterm parameter -SNA-E-LENTOOLON, transmit byte count exceeds buffer length Problems Addressed in the SNA3270_E01016 Kit: o Local OpenVMS Alpha users can now connect to Compaq SNA Server without using a network connection. This is similar to OpenVMS VAX local users connections to VMS/SNA. Example: $SET HOST/SNA 0. o Fixed a problem where the connection failed to a gateway because the terminal ID was longer than 32 bytes. The following error was returned: %SNA-E-INVTRMPAR, invalid authterm parameter -SNA-E-LENTOOLON, transmit byte count exceeds buffer length INSTALLATION NOTES: The ECO kit is installed with the VMSINSTAL command procedure. The system/cluster does not need to be rebooted after this kit is installed. Please follow the instructions in the DECnet SNA 3270 Data Stream Programming Interface Installation Guide to make the new software active. The ECO kit checks to ensure that a valid license is installed before proceeding. If one is not found, the installation aborts. All trademarks are the property of their respective owners.



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

sna3270_e02016.README
.CHKSUM
sna3270_e02016.a-dcx_axpexe
sna3270_e02016.a-dcx_vaxexe
sna3270_e02016.CVRLET_TXT

privacy and legal statement