SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
DSPI SNA3270_E01015 DECnet/SNA Data Stream Prog. Interface V1.5 ECO Summary

NOTE: An OpenVMS saveset or PCSI installation file is stored on the Internet in a self-expanding compressed file. The name of the compressed file will be kit_name-dcx_vaxexe for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha. Once the file is copied to your system, it can be expanded by typing RUN compressed_file. The resultant file will be the OpenVMS saveset or PCSI installation file which can be used to install the ECO. Copyright (c) Digital Equipment Corporation 1997. All rights reserved. PRODUCT: DECnet/SNA Data Stream Programming Interface OP/SYS: OpenVMS Alpha, V6.1, V6.1-1H1, V6.1-1H2, V6.2, V6.2-1H1, V6.2-1H2, V6.2-1H3 V7.0 OpenVMS VAX V6.1, V6.2, V7.0 SOURCE: Digital Equipment Corporation ECO INFORMATION: ECO Kit Name: SNA3270_E01015 ECO Kits Superseded by This ECO Kit: None ECO Kit Approximate Size: 11,358 Blocks Kit Applies To: DECnet/SNA Data Stream Programming Interface V1.5 System/Cluster Reboot Necessary: No Installation Rating: Unknown NOTE: In order to receive the full fixes listed in this kit, the following remedial kits also need to be installed: None ECO KIT SUMMARY: An ECO kit exists for SNA DSPI V1.5 on OpenVMS V6.1 through V7.0. Problems Addressed in the SNA3270_E01015 Kit: o GAI_CLOSE would not deallocate channels on abnormal disconnects This has now been corrected and the sna__rcv_callback routine now will deallocate the channels. o Pacing indicator was never being set on first request RH in pacing window when sending data to host. This has now been corrected in the SNA__PAC_RQ_SEND routine. o Pacing not working properly when a pacing value was specified. This has been corrected in the sna__tc_dequeue_q_pac by checking if pacing_count is greater than zero. Previously pacing_window was being checked in error. The DECnet SNA Data Stream Programming Interface Release Notes contain a complete explanation of this release. INSTALLATION NOTES: The system/cluster does not need to be rebooted after this kit is installed. The ECO kit checks to ensure that a valid license is installed before proceeding. If one is not found, the installation aborts.



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

sna3270_e01015.README
sna3270_e01015.CHKSUM
sna3270_e01015.CVRLET_TXT
sna3270_e01015.a-dcx_axpexe
sna3270_e01015.a-dcx_vaxexe

privacy and legal statement