OPEN3D OPEN3D_E12024 DEC Open3D V2.4 for OpenVMS AXP ECO Summary
Copyright (c) Digital Equipment Corporation 1994. All rights reserved.
PRODUCTS: DEC Open3D for OpenVMS AXP
DECwindows Motif[R] for OpenVMS AXP
OP/SYS: OpenVMS Alpha
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: OPEN3D_E12024
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 7600 Blocks
Kit Applies To: DEC Open3D V2.4
DECwindows Motif V1.1, V1.2
OpenVMS Alpha V6.1
System Reboot Necessary: No
ECO KIT SUMMARY:
An ECO kit exists for DEC Open3D V2.4 on OpenVMS Alpha V6.1. This kit
addresses the following problems:
o Symbols (polymarkers) changing color under extreme load when
clipped.
This problem occurred with an PHIGS (PEX protocol) application that
displayed large numbers of polymarkers, lines and text and then
frequently updated the display. Occasionally, when the display was
updated and new colors for some symbols, lines and text had been
requested, the line and text entities changed properly, but some
symbols retained the "old" color.
o PEX HitTest malfunction.
This problem was experienced with a PHIGS (PEX protocol)
application. When multiple instances of the same object were
displayed, then many of these instances were picked or "selected"
using the PEX HitTest function, all objects were properly
lit/selected except the first in the picked series.
o Window Refresh with Resize.
When a PHIGS application's graphics window was resized to a smaller
area then resized back to the original or larger area, the window
contents appeared to not scale properly or were clipped.
o Leading line color wrong for bitmap text.
This problem was found with a PHIGS (PEX protocol) application.
Leading lines for bitmap precision annotation text were incorrectly
using the current text color. Instead, the leading line should be
assigned polyline attributes in accordance with the ANSI standard
for PHIGS '88, page 142.
INSTALLATION NOTES:
The system/cluster does not need to be rebooted after this kit is
installed. However, the server must be restarted after the installation
of this kit.
NOTE: Please note that the actual name for the DEC Open3D ECO saveset
is OPEN3D_E12024. This name is different than what is documented
in the ECO Release Notes.
[R] Motif is a registered trademark of the Open Software Foundation, Inc.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
open3d_e12024.README
open3d_e12024.CHKSUM
open3d_e12024.a-dcx_axpexe
|