MEP_VT MEPR3270E02011 MEP VT for DEC SNA 3270 App Svcs V1.1 ECO Summary
Copyright (c) Digital Equipment Corporation 1994.
All rights reserved.
PRODUCT: MEP VT for DEC SNA 3270 Application Services
OP/SYS: OpenVMS VAX
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: MEPR3270E02011
ECO Kits Superseded by This Kit: MEPRTL_R3270011
ECO Kit Approximate Size: 1575 Blocks
Kit Applies To: MEP VT for DEC SNA 3270
Application Services V1.1
System Reboot Necessary: NO
ECO KIT SUMMARY:
An ECO kit exists for MEP VT for DEC SNA 3270 Application Services V1.1
on OpenVMS VAX V5.5 or later. This kit addresses the following
problem:
The MEPRTL_R3270 corrupted data by prepending several NULL
characters to input data received, prior to passing it on to the
R3270_LIBSHR, which was running in passthru mode: for example,
when the terminal is a block mode, 3270 terminal or TE.
At this point in time this problem has shown up intermittently,
only when running a DECforms application on top of MEPVT/R3270 when
talking to a blockmode terminal. The occurance of this problem
resulted in the following DECforms error and termination of the
DECforms application:
FORMS-E-DEVERR, device I/O error
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
mepr3270e02011.README
mepr3270e02011.CHKSUM
mepr3270e02011.a-dcx_vaxexe
|