SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
DECforms FORMSAECO01021 DECforms V2.1 OpenVMS Alpha ECO Summary

Copyright (c) Digital Equipment Corporation 1995. All rights reserved. PRODUCT: DECforms for OpenVMS COMPONENT: FORMS$CIOSHR.EXE OP/SYS: OpenVMS Alpha SOURCE: Digital Equipment Corporation ECO INFORMATION: ECO Kit Name: FORMSAECO01021 ECO Kits Superseded by This ECO Kit: None ECO Kit Approximate Size: 570 Blocks Kit Applies To: DECforms V2.1 for OpenVMS OpenVMS Alpha V6.1 or higher System Reboot Necessary: No ECO KIT SUMMARY: An ECO kit exists for DECforms V2.1 on OpenVMS Alpha V6.1 or higher. This kit addresses the following problems: Problems addressed in the FORMSAECO01021 Kit: o Problem loading a form created using the Alpha DECforms V1.4(C/D) translator /NOMEMBER_ALIGNMENT switch. These old style form's records were treated as naturally aligned even though the /NOMEMBER_ALIGNMENT switch was specified when they were translated. o Form load problem causes a hang condition due to an infinite loop. When multiple extracted form objects are linked into an image and they had been extracted using an older version of DECforms prior to DECforms V2.1, a hang condition may occur. If tracing was enabled, the trace file would end with the message: "Converting an old style form object to latest format" o "Session Not Found" errors and possible PEU call argument errors resulting in a fatal exception. These errors are a result of a form object conversion error where call argument alignment size calculations were performed incorrectly. This problem typically occurs on OpenVMS VAX but could occur using VESTed images on OpenVMS Alpha. INSTALLATION NOTES: The system/cluster does not need to be rebooted after this kit is installed. However, if ACMS is running on your system, you will have to shut it down before installing this ECO. After the installation is complete, restart ACMS and restart the ACMS application so that the new FORMS$CIOSHR image will be used.



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

formsaeco01021.README
formsaeco01021.CHKSUM
formsaeco01021.CVRLET_TXT
formsaeco01021.a-dcx_axpexe

privacy and legal statement