DECnet/OSI DNVOSIA_E01071 DECnet-Plus V7.1 For OpenVMS VAX ECO Summary
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
The name of the compressed file will be kit_name-dcx_vaxexe
for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
Once the file is copied to your system, it can be expanded
by typing RUN compressed_file. The resultant file will
be the OpenVMS saveset or PCSI installation file which
can be used to install the ECO.
Copyright (c) Digital Equipment Corporation 1995. All rights reserved.
PRODUCT: DECnet-Plus V7.1 for OpenVMS Alpha
OP/SYS: OpenVMS Alpha
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: DNVOSIA_E01071
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 24,000 Blocks
Kit Applies To: DECnet-Plus V7.1 for OpenVMS Alpha
OpenVMS Alpha V7.0, V7.1
System Reboot Necessary: Yes
ECO KIT SUMMARY:
An ECO kit exists for DECnet-Plus V7.1 for OpenVMS Alpha on OpenVMS
Alpha V7.0 through V7.1. This kit addresses the following problems.
A. Corrections for Base Components
-------------------------------------------------------------------------------
Corrections made to SYS$LIBRARY:CDI$SHR.EXE
Image Identification: "V7.1-ECO01" 15-JUL-1997 17:47:20.74
- Add support for sticky cache entry.
- Set default cache expiration timer to 0 (ie infinite),
not either 7 or 30 days.
- Convert old V1.0 and V2.2 cache files to V2.3 cache files
to preserve cache with upgrades.
-------------------------------------------------------------------------------
Corrections made to SYS$SYSTEM:NCL.EXE
Image Identification: "V7.1-ECO01" 18-JUN-1997 15:47:06.99
- CMIP encoding/decoding correction for "CML-E-INVALID_PDU".
- Add support for "With" clause.
-------------------------------------------------------------------------------
Corrections made to SYS$UPDATE:DECNET_MIGRATE:
File Identification: "V7.1-ECO01" 13-MAR-1997 13:26:54.08
- Include COLLECT and SHOW PATH correction for the error
"Unsupported primary directory service."
-------------------------------------------------------------------------------
Corrections made to SYS$SYSTEM:DECNET_REGISTER:
Image Identification: "V7.1-ECO01" 12-MAR-1997 17:36:34.54
- Correct search for Phase IV node name database in SYS$COMMON.
- Use DECdns high confidence to register nodes correctly.
This prevents the error:
%DNS-E-UNKNOWNENTRY, Requested name does not exist.
After the initial error, the node object was deleted, but
the .DNA_BackTranslation was left so that subsequent attempts
to register the node failed with "name already in use".
-------------------------------------------------------------------------------
Corrections made to SYS$UPDATE:DTSS$TIMEZONE_RULES.DAT:
File Identification: "V7.1-ECO01" 1-AUG-1996 15:22:01.23
- Change DTSS MET time zone rule for 1996 and 1997
daylight savings time from the last Sunday in September
to the last Sunday in October. NET$CONFIGURE.COM must
be run to update the rule.
-------------------------------------------------------------------------------
Corrections made to SYS$SYSTEM:NCP
Image Identification: "V7.1-ECO01" 12-MAR-1997 13:09:24.67
- Prevent possible access violation with proxies.
-------------------------------------------------------------------------------
Corrections made to SYS$SYSTEM:NET$ACP
Image Identification: "V7.1-ECO01" 15-JUL-1997 18:15:25
- Included for support of CDI$SHR.
-------------------------------------------------------------------------------
Corrections made to SYS$MANAGER:NET$CONFIGURE.COM:
File Identification: "V7.1-ECO02" 4-AUG-1997 11:33:45.76
- Correct the use of SYS$COMMON for DECnet Migration
temporary files.
- Require LOCAL in the Session Control Search Path
on DECdns servers.
- Correct the use of logical name definitions for script
files.
- NET$STARTUP_RENAME.COM could be created with an invalid
node name.
- Add a Flow Control Policy Option for NSP Transport.
- Correct DCL command syntax error on NSP configuration
section within option 4.
--------------------------------------------------------------------------------
Corrections made to SYS$SYSTEM:NET$EVENT_DISPATCHER:
Image Identification: "V7.1-ECO01" 22-JUL-1997 10:40:48.51
- Included for compatibility with NET$PROCESS_EMAA.
--------------------------------------------------------------------------------
Corrections made to SYS$MANAGER:NET$SHUTDOWN.COM:
File Identification: "V7.1-ECO01" 9-JUL-1997 14:19:43.65
- Allow DECdns Clerk shutdown to be last.
--------------------------------------------------------------------------------
Corrections made to SYS$UPDATE:NET$CONVERT_DATABASE:
File Identification: "V7.1-ECO01" 15-JUL-1997 15:11:39.96
- Remove erroneous log file message "found 0 nodes".
- Prevent database conversion to an invalid command:
"SET NODE 0 CSMA-CD STATION MNA-0 STATION BUFFERS 15"
in NET$CSMACD_STARTUP.NCL.
--------------------------------------------------------------------------------
Corrections made to SYS$LOADABLE_IMAGES:NET$ALIAS.EXE
Image Identification: "V7.1-ECO01" 24-JUN-1997 10:11:20.52
- Correctly configure multiple aliases.
- Prevent alias hang on startup. If NET$ACP was very busy,
the alias task could sometimes get suspended while
holding the object lock in exclusive mode. The solution
is to increase the priority of the alias task.
- Correct alias selection weight of one.
--------------------------------------------------------------------------------
Corrections made to SYS$LOADABLE_IMAGES:NET$DRIVER.EXE:
Image Identification: "V7.1-ECO01" 9-JUL-1997 11:06:27.32
- Correct incoming disconnect with DNA where a
a UCB could be left around.
- Correct disconnect path that could lead to hanging
transport ports if the outgoing connect initiate was
not getting properly disconnected.
--------------------------------------------------------------------------------
Corrections made to SYS$LOADABLE_IMAGES:NET$LOOP_APPLICATION.EXE:
File Identification: "V7.1-ECO01" 15-JUL-1997 16:18:53.68
- Correct application loopback error "Agent is invalid"
when connecting by destination tower.
--------------------------------------------------------------------------------
Corrections made to SYS$SYSTEM:NET$MOP:
Image Identification: "V7.1-ECO01" 22-JUL-1997 11:08:28.18
- Save unnecessary disk access on dump requests.
- Add a new diagnostic error for Console Carrier Request
"CCR$_DuplicateAddr, duplicate address error" to help
resolve a configuration error.
--------------------------------------------------------------------------------
Corrections made to SYS$LOADABLE_IMAGES:NET$MOPS0.EXE:
Image Identification: "V7.1-ECO01" 22-JUL-1997 11:08:29.79
- VAX only correction for a kernel dispatch table
to a nonpaged psect.
--------------------------------------------------------------------------------
Corrections made to SYS$LIBRARY:NET$PROCESS_EMAA.EXE:
Image Identification: "V7.1-ECO01" 22-JUL-1997 10:08:45.88
- Prevent possible system crash with a negative or zero
entity count in the IVK.
--------------------------------------------------------------------------------
Corrections made to SYS$LOADABLE_IMAGES:NET$OSDRIVER.EXE:
Image Identification: "V7.1-ECO01" 9-JUL-1997 11:06:31.86
- Correct incoming disconnect with VOTS where a
a UCB could be left around.
--------------------------------------------------------------------------------
Corrections made to SYS$LOADABLE_IMAGES:NET$OSVCM.EXE:
Image Identification: "V7.1-ECO01" 9-JUL-1997 13:20:49.42
- Correct lost "fillm" when a connection was not processed
by the application before the timeout.
--------------------------------------------------------------------------------
Corrections made to SYS$LOADABLE_IMAGES:NET$ROUTING_ES.EXE:
Image Identification: "V7.1-ECO01" 17-JUL-1997 14:12:43.42
- Prevent a crash when deleting a reachable address due
to erroneous cache size.
- Prevent possible crash in routing shutdown.
--------------------------------------------------------------------------------
Corrections made to SYS$LOADABLE_IMAGES:NET$ROUTING_IS.EXE:
Image Identification: "V7.1-ECO01" 24-JUN-1997 12:14:56.13
- Prevent synchronous data link crash in Host Based Routing.
- Correct an error with CTF trace processing.
- Alias section weight set to 1 should receive incoming
connections. Correct an error in the round robin search loop.
- Prevent crash with alias when the circuit was deleted.
--------------------------------------------------------------------------------
Corrections made to SYS$LOADABLE_IMAGES:NET$SESSION_CONTROL.EXE:
Image Identification "V7.1-ECO01" 9-JUL-1997 11:31:07.94
- Prevent "invalid access" with user IDs longer then 12 characters.
- Use proxy first regardless of session attributes.
- Add support for the configuring of multiple aliases by setting
the outgoingalias name and default in the application.
- Change the disconnect status sent to the remote node when
session control is disabled on an existing connection from;
"%SYSTEM-F-SHUT, remote node no longer accepting connects" to
"%SYSTEM-F-THIRDPARTY, network logical link disconnected by a
third party"
- Prevent "PGFIPLHI, Page Fault IPL Too High", in NET$ACP on
system boot.
- Prevent possible incoming disconnect crash.
--------------------------------------------------------------------------------
Corrections made to SYS$SYSTEM:NET$SDA.EXE:
Image Identification: "V7.1" 16-NOV-1996 01:46:17.90
--------------------------------------------------------------------------------
Corrections made to SYS$LOADABLE_IMAGES:NET$TRANSPORT_NSP.EXE:
Image Identification: "V7.1-ECO01" 13-MAY-1997 15:05:38.38
- Prevent hang on shutdown.
--------------------------------------------------------------------------------
Corrections made to SYS$LOADABLE_IMAGES:NET$TRANSPORT_OSI.EXE:
Image Identification: "V7.1-ECO01" 20-JUN-1997 15:41:37.40
- Prevent possible crash with deactivate port.
--------------------------------------------------------------------------------
Corrections made to SYS$STARTUP:NET$STARTUP.COM:
File Identification: "V7.1-ECO01" 24-JUL-1997 11:20:09.35
- Node rename temporary file should only be executed if
initial start was successful.
--------------------------------------------------------------------------------
Update to SYS$LOADABLE_IMAGES:SYS$NETWORK_SERVICES.EXE:
Image Identification: "V7.1-ECO01" 21-JUL-1997 10:09:06.04
- Update ECO number in DECnet version "050C01"
--------------------------------------------------------------------------------
INSTALLATION NOTES:
This ECO is installed using the POLYCENTER Software Installation
utility.
Product Kit Name: DNVOSIAE01071
PCSI Kit Name: DEC-AXPVMS-DNVOSIECO01-V0701--4.PCSI;1
In order for the corrections in this kit to take effect, the system
must be rebooted. If the system is a member of a VMScluster, the
entire cluster should be rebooted. The reboot may be postponed if
it is not convenient to do it during installation of this ECO.
However, the new driver(s) will not take effect until after a
reboot.
Installation Overview
Install this kit with the POLYCENTER Software Installation utility (PCSI)
by logging into the SYSTEM account, and entering the following command at
the DCL prompt:
$ PRODUCT INSTALL DNVOSIECO01/SOURCE=[location of the .PCSI file]
Note that the DECwindows Motif interface to PCSI may also be used.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
dec-axpvms-dnvosieco01-v0701--4.README
dec-axpvms-dnvosieco01-v0701--4.CHKSUM
dec-axpvms-dnvosieco01-v0701--4.CVRLET_TXT
dec-axpvms-dnvosieco01-v0701--4.pcsi-dcx_axpexe
|