OpenVMS ALPOPDR05_061 Alpha V6.1 - V6.1-1H2 OPDRIVER ECO Summary
Copyright (c) Digital Equipment Corporation 1994, 1995. All rights reserved.
OP/SYS: OpenVMS Alpha
COMPONENT: OPDRIVER
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: ALPOPDR05_061
ECO Kits Superseded by This ECO Kit: AXPOPDR04_061 (AXPOPDR)
AXPOPDR03_061
AXPOPDR02_061
AXPOPDR01_061
ECO Kit Approximate Size: 216 Blocks
Kit Applies To: OpenVMS Alpha V6.1 through V6.1-1H2
System/Cluster Reboot Necessary: Yes
ECO KIT SUMMARY:
An ECO kit exists for OPDRIVER on OpenVMS Alpha V6.1 through V6.1-1H2.
This kit addresses the following problems:
Problems addressed in the ALPOPDR05_061 kit:
o Occassionally, when output is going to OPA1, a 'WRITE SYS$OUTPUT'
timeout will occur.
Problems addressed in the AXPOPDR04_061 kit:
o The AXPOPDR01_061, AXPOPDR02_061 and AXPOPDR03_061 kits did
not apply to OpenVMS AXP V6.1-1H2. This kit takes the fixes
from those previous kits and also applies them to V6.1-1H2.
Problems addressed in the AXPOPDR03_061 kit:
o The Alpha DEC 2000-300 system will not do MODEM control on port
OPA1. The following DCL command on port OPA1 will not work:
$ SET TERMINAL/PERM/MODEM OPA1
Problems addressed in the AXPOPDR02_061 kit:
o When any OpenVMS AXP SMP (multi-CPU) system that has a modem
connected to OPA1 tries to do a SET HOST/DTE, system access
succeeds but in a short time the machine will crash.
Problems addressed in the AXPOPDR01_061 kit:
o When a SET TERM/SPEED=xxxx is done on the serial port OPA1
(the small MMJ connector on the back of DEC 3000-500 and DEC
3000-400 systems) nothing happens. The baud rate stays locked
at 9600 no matter what it is set to. A "SHOW TERM" indicates
that the speed has been changed but the port still operates
at 9600 baud.
INSTALLATION NOTES:
In order for the corrections in this kit to take effect, the system
must be rebooted. If the system is a member of a VMScluster, the
entire cluster should be rebooted.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
alpopdr05_061.README
alpopdr05_061.CHKSUM
alpopdr05_061.CVRLET_TXT
alpopdr05_061.a-dcx_axpexe
|