SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
OpenVMS ALPDRIV12_061 Alpha V6.1 LRDRIVER ECO Summary

NOTE: An OpenVMS saveset or PCSI installation file is stored on the Internet in a self-expanding compressed file. The name of the compressed file will be kit_name-dcx_vaxexe for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha. Once the file is copied to your system, it can be expanded by typing RUN compressed_file. The resultant file will be the OpenVMS saveset or PCSI installation file which can be used to install the ECO. *OpenVMS] ALPDRIV12_061 Alpha V6.1 LRDRIVER ECO Summary Copyright (c) Digital Equipment Corporation 1995, 1996. All rights reserved. OP/SYS: OpenVMS Alpha COMPONENT: LRDRIVER SOURCE: Digital Equipment Corporation ECO INFORMATION: ECO Kit Name: ALPDRIV12_061 ECO Kits Superseded by This ECO Kit: ALPDRIV11_061 ALPDRIV09_061 ECO Kit Approximate Size: 216 Blocks Kit Applies To: OpenVMS Alpha V6.1, V6.1-1H1, V6.1-1H2 System/Cluster Reboot Necessary: Yes ECO KIT SUMMARY: An ECO kit exists for LRDRIVER on OpenVMS Alpha V6.1 through V6.1-1H2. This kit addresses the following problems: Problems addressed in ALPDRIV12_061: o The ALPDRIV11_061 remedial kit did not check to see if the system the kit was being installed on was an SMP (multi-processor) system. If the system is an SMP system and the AXPSYS07_061 remedial kit is not installed, installing the ALPDRIV11_061 kit will lead to system instability. The ALPDRIV12_061 kit installation procedure will check to see if the system the kit is being installed on is an SMP (multi-processor) system. If so, the kit will check to see if the AXPSYS07_061 remedial kit has been installed. If not, ALPDRIV12_061 will not install. This is a problem for SMP systems only. Problems addressed in ALPDRIV11_061: o All known problems with TAB expansions. o Random non-useful completion status is sometimes returned. The correct, meaningful error status is now returned. o The system might crash with a double deallocate when a device is spooled. o Random garbage characters may be printed when the printer is set to 'DEVICE/PRINTALL.' o Problems may exist with DEClaser 1152 and third-party CalComp[TM] & Tektronics[R] plotters and LP27s. These problems are fixed in OpenVMS Alpha V7.0. Problems addressed in ALPDRIV09_061: o If the following commands are executed: $DEFINE/FORM/NOWRAP/NOTRUNC FORMNAME FORMNUMBER $SET DEVICE /SPOOLED LRA0: $INIT/QUEUE/START/ON=NODE::LRA0/DEF=(NOFEED,NOFLAG,- $_NOBURST,NOTRAILER,FORM=FORMNAME) queuename $SET PRINTER/CR/NOFALLBACK/FF/LOWER/PAGE=66/PASSALL- $_/PRINTALL/TAB/NOTRUNC/UNKNOWN/WIDTH=132/NOWRAP LRA0: $PRINT/QUEUE=queuename/FORM=formname/PASSALL filename After 2 minutes the queue goes into stalled status. If the customer then tries: STOP/QUEUE queuename SET DEVICE/NOSPOOLED LRA0: The system will crash with a double deallocation memory error due to incorrect register usage. INSTALLATION NOTES: In order for the corrections in this kit to take effect, the system must be rebooted. If the system is a member of a VMScluster, the entire cluster must be rebooted. REFERENCES: [TM] CalComp is a trademark of Lockheed Corporation. [R] TEKTRONIX is a registered trademark of Tektronix, Inc.



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

alpdriv12_061.README
alpdriv12_061.CHKSUM
alpdriv12_061.CVRLET_TXT
alpdriv12_061.a-dcx_axpexe

privacy and legal statement