OpenVMS ALP_CN_Y2K01_062 Hanzi/Alpha V6.2 Y2K ECO Summary
TITLE: OpenVMS ALP_CN_Y2K01_062 Hanzi/Alpha V6.2 Y2K ECO Summary
Modification Date: 13-JUL-98
Modification Type: New Kit
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
The name of the compressed file will be kit_name-dcx_vaxexe
for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
Once the file is copied to your system, it can be expanded
by typing RUN compressed_file. The resultant file will
be the OpenVMS saveset or PCSI installation file which
can be used to install the ECO.
*OpenVMS] ALP_CN_Y2K01_062 Hanzi/Alpha V6.2 Y2K ECO Summary
Copyright (c) Digital Equipment Corporation 1998. All rights reserved.
OP/SYS: DIGITAL OpenVMS/Hanzi Alpha
COMPONENT: HDUMP
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: ALP_CN_Y2K01_062
ECO Kits Superseded by This ECO Kit: None
ECO Kit Approximate Size: 378 Blocks
Kit Applies To: OpenVMS/Hanzi Alpha V6.2
System/Cluster Reboot Necessary: No
Rolling Re-boot Supported: Not Applicable
Installation Rating: 1 - To be installed on all systems running
the listed version(s) of OpenVMS.
Kit Dependencies:
The following remedial kit(s) must be installed BEFORE
installation of this kit:
None
In order to receive all the corrections listed in this
kit, the following remedial kits should also be installed:
ALPY2K0n_062
ECO KIT SUMMARY:
An ECO kit exists for the HDUMP utility on OpenVMS Hanzi/Alpha
V6.2. This kit addresses the following problems.
This document contains release notes for the OpenVMS/Hanzi Alpha
Year 2000 enhancements that ship in kit ALP_CN_Y2K01_062. To
receive all the Year 2000 enhancements for OpenVMS/Hanzi Alpha V6.2,
you must also install the V6.2 Year 2000 kit (ALPY2K0n_062).
The enhancements included in kit ALPY2K0n_062 are detailed in the
README file and Release Notes that ship with that kit. You can
also access the Release Notes for that kit from the OpenVMS Year
2000 home page on the World Wide Web:
http://www.openvms.digital.com/openvms/products/year-2000
o The OpenVMS/Hanzi HDUMP utility, which supports the ODS-1 file
system using a 2-digit year format, has been modified to cor-
rectly interpret these 2-digit years until the year 2057.
INSTALLATION NOTES:
The system/cluster does not need to be rebooted after this kit is
installed.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
alp_cn_y2k01_062.README
alp_cn_y2k01_062.CHKSUM
alp_cn_y2k01_062.CVRLET_TXT
alp_cn_y2k01_062.a-dcx_axpexe
|