SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
OpenVMS ALP4D20T01_071 Alpha V7.1-V7.1-1 4D10T Support ECO Summary

TITLE: OpenVMS ALP4D20T01_071 Alpha V7.1-V7.1-1 4D10T Support ECO Summary Modification Date: 29-NOV-99 Modification Type: Documentation - "ELSA/Gloria" should be "ELSA Gloria" and PBXGK-BB/AA should be PBXGK-BB/BC. NOTE: An OpenVMS saveset or PCSI installation file is stored on the Internet in a self-expanding compressed file. The name of the compressed file will be kit_name-dcx_vaxexe for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha. Once the file is copied to your system, it can be expanded by typing RUN compressed_file. The resultant file will be the OpenVMS saveset or PCSI installation file which can be used to install the ECO. Copyright (c) Compaq Computer Corporation 1999. All rights reserved. PRODUCT: OpenVMS Alpha COMPONENTS: DECW$SERVER_DDX_CFB.EXE DECW$SERVER_DDX_CFB16.EXE DECW$SERVER_DDX_CFB32.EXE DECW$SERVER_DDX_GZ.EXE DECW$SERVER_DIX.EXE SYS$GZDRIVER.EXE SOURCE: Compaq Computer Corporation ECO INFORMATION: ECO Kit Name: ALP4D20T01_071 ECO Kits Superseded by This ECO Kit: None ECO Kit Approximate Size: 5454 Blocks Kit Applies To: OpenVMS Alpha V7.1, V7.1-1H1, V7.1-1H2 System/Cluster Reboot Necessary: Yes Rolling Re-boot Supported: Yes Installation Rating: INSTALL_2 - To be installed on all systems running the listed version(s) of OpenVMS and using the following feature(s): Compaq PowerStorm 4D10T (ELSA Gloria) Graphics Option (PBXGK-BB/BC) Kit Dependencies: The following remedial kit(s) must be installed BEFORE installation of this kit: DECwindows Motif for OpenVMS Alpha V1.2* (the product, not an ECO) In order to receive all the corrections listed in this kit, the following remedial kits should also be installed: None ECO KIT SUMMARY: An ECO kit exists adding support for the Compaq PowerStorm 4D10T (ELSA Gloria) Graphics Option (DECW$SERVER_DDX_CFB, DECW$SERVER_DDX_CFB16, DECW$SERVER_DDX_CFB32, DECW$SERVER_DDX_GZ, DECW$SERVER_DIX, SYS$GZDRIVER.EXE) on OpenVMS Alpha V7.1 through V7.1-1H2. This kit addresses the following: New Functionality Addressed in the ALP4D20T01_071 Kit: o This kit provides OpenVMS V7.1 support for the Compaq PowerStorm 4D10T graphics option. You should install this kit after installing the Motif layered product. After installation, graphics operation of the 4D10T option will automatically start graphics after system boot. The default graphics settings are 1024x768 @70Hz with 8-bit pixels. Additional resolutions are available, depending on the monitor and environment: 640 x 480 8/24-bit 60, 65, 70, 75, and 85Hz 800 x 600 8/24-bit 60, 65, 70, 75, and 85Hz 1024 x 768 8/24-bit 60, 65, 70, 75, and 85Hz 1152 x 1024 8/24-bit 60, 65, 70, 75, and 85Hz 1280 x 1024 8/24-bit 60, 65, 70, 75, and 85Hz 1600 x 1200 8-bit only 60, 65, 70, 75Hz 1600 x 1280 8-bit only 60, 65, 70Hz 1920 x 1200 8-bit only 60, 65, 70Hz These settings are changed by renaming: SYS$MANAGER:DECW$PRIVATE_SERVER_SETUP.TEMPLATE to SYS$MANAGER:DECW$PRIVATE_SERVER_SETUP.COM and following the directions in the file (for example): $ define/exec/system/nolog decw$server_refresh_rate 75 $ define/exec/system/nolog decw$server_pixel_depth 24 $ decw$xsize_in_pixels == 1280 $ decw$ysize_in_pixels == 1024 Note that Compaq recommends that the refresh rate be 70Hz or above to avoid screen flicker with room lighting. In addition, the monitor determines the highest settings. For instance, many monitors will not support greater than 1280x1024, or may only support that resolution at lower (60Hz) refresh rates. For multiple heads, there can be separate values for each monitor: $ define/exec/system/nolog decw$server_refresh_rate 75, 60, 70 $ define/exec/system/nolog decw$server_pixel_depth 24, 8, 8 $ decw$xsize_in_pixels == "1280, 640, 1600" $ decw$ysize_in_pixels == "1024, 480, 1280" The 4D10T has been tested with up to 7 heads. Only 4D10T cards should be used together. Combinations with non-4D10T cards have not been tested, and may not work. INSTALLATION NOTES: The images in this kit will not take effect until the system is rebooted. If there are other nodes in the VMScluster, they must also be rebooted in order to make use of the new image(s). If it is not possible or convenient to reboot the entire cluster at this time, a rolling re-boot may be performed. All trademarks are the property of their respective owners.



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

alp4d20t01_071.README
alp4d20t01_071.CHKSUM
alp4d20t01_071.CVRLET_TXT
alp4d20t01_071.a-dcx_axpexe
alp4d20t01_071.CVRLET_TXT

privacy and legal statement