SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
MAILWRKS-VMS A1MAIL_ECO05012 DEC MAILworks Server V1.2 ECO Summary

Copyright (c) Digital Equipment Corporation 1994. All rights reserved. PRODUCT: DEC MAILworks Server for OpenVMS V1.2 OP/SYS: OpenVMS VAX SOURCE: Digital Equipment Corporation ECO INFORMATION: ECO Kit Name: A1MAIL_ECO05012 ECO Kits Superseded by This Kit: A1MAIL_ECO04012 A1MAIL_ECO03012 A1MAIL_ECO02012 A1MAIL_ECO01012 ECO Kit Approximate Size: Saveset A - 3042 Blocks Saveset B - 10332 Blocks Saveset C - 3312 Blocks Total of 3 files - 16686 Blocks Kit Applies To: DEC MAILworks Server for OpenVMS V1.2 System Reboot Necessary: NO ECO KIT SUMMARY: An ECO (patch) kit exists for DEC MAILworks Server for OpenVMS VAX V1.2 on OpenVMS VAX V5.4 or later. This kit includes all fixes from previous ECO kits as well as the following: o The MUAS Server and the Connect Server have been modified to allocate memory in a more efficient way. o The MUAS Server properly handles messages submitted by DECfax that have an unknown ASN.1 ID. o The MUAS Server properly handles an RMS error while processing a delivery thread. o Modified error reporting of servers to report RMS errors in their respective _output.log files. o A corrupt profile entry is properly handled by the MUAS server. o Connects by the DASL-based clients are properly handled. o If NETBIOS goes down, the MUAS Server now attempts to re-enable NETBIOS several times. o Read-only shared drawers are properly implement. o A user disconnect during a large DDS find is properly handled. o A Connect message that contains no username is properly handled. o Setting the REDIRECT_ADDRESS to an Internet account is properly handled. o To diagnose problems relating to particular log events it is now possible to allow process dumps of either of the MUAS Server or the Connect Server based on a particular log event. o The Connect Server will now disconnect a client that has hit a context threshold limit. o The command procedure used by the VMS clients to purge the wastebasket properly invokes the VT client. o Both the MUAS and Connect Server have been modified to allow collection of dumps should either of them hang. o The VT client has been modified to fix random access violations on messages with unusually large distribution lists. o The A1MAIL$PRINT server has been modified to work with the security modifications made in V6.0 of OpenVMS. o The DS servers have been modified so they no longer randomly enter a looping state. o The cause of the error 'invalid item 2306' in the MUAS server has been corrected and this will no longer occur. This had the side effect of delivery notification either not being delivered or being delivered on a retry.



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

a1mail_eco05012.README
a1mail_eco05012.CHKSUM
a1mail_eco05012.a-dcx_vaxexe
a1mail_eco05012.b-dcx_vaxexe
a1mail_eco05012.c-dcx_vaxexe

privacy and legal statement