ALL-IN-1 A1ADA_ECO01031 Office Server Options AIDA component ECO Summary
NOTE: An OpenVMS saveset or PCSI installation file is stored
on the Internet in a self-expanding compressed file.
The name of the compressed file will be kit_name-dcx_vaxexe
for OpenVMS VAX or kit_name-dcx_axpexe for OpenVMS Alpha.
Once the file is copied to your system, it can be expanded
by typing RUN compressed_file. The resultant file will
be the OpenVMS saveset or PCSI installation file which
can be used to install the ECO.
Copyright (c) Digital Equipment Corporation 1996. All rights reserved.
PRODUCT: ALL-IN-1 Office Server Options for OpenVMS AXP and
OpenVMS VAX, V3.1
COMPONENT: AIDA Server
OP/SYS: OpenVMS Alpha V6.1 or later
OpenVMS VAX V5.5-2 or later
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: A1ADA_ECO01031
ECO Kits Superseded by This ECO Kit: None
NOTE: This ECO kit was previously packaged as saveset
A1_FIX038031.A. It obsoletes the patch kits
A1_FIX030031.A and A1_FIX038031.A.
ECO Kit Approximate Size: 3078 Blocks
System Reboot Necessary: No
ECO KIT SUMMARY:
An ECO kit exists for ALL-IN-1 Office Server Options for OpenVMS AXP and
OpenVMS VAX Version 3.1 on OpenVMS Alpha V6.1 or later and OpenVMS VAX
V5.5-2 or later.
This ECO kit contains a selection of code-level fixes for the 'AIDA'
component of ALL-IN-1 Version 3.1. If a patched system is later
upgraded to TLC V2.5, the fixes supplied by patch A1ADA_ECO01031 will be
lost. Under these circumstances this patch kit should be reapplied
after the upgrade.
The A1ADA_ECO01031 Release Notes contain a complete explanation of this
release. Below is a brief description:
o AIDA server problems on OpenVMS VAX and OpenVMS Alpha V6.2
TeamLinks users are unable to access system distribution lists
resident on ALL-IN-1 V3.1 systems running OpenVMS VAX or OpenVMS
Alpha V6.2 or later. This problem only occurs when Distributed
Directory Services (DDS) is also being accessed by the AIDA server.
Similarly TeamLinks users are unable to access certain datasets,
where these are being referenced using the users default VMS
privileges.
o AIDA Server problems due to low resources
This patch introduces a resource monitor to watch resource
utilization levels, and issue warnings to the log file when they
reach set boundaries.
The monitor runs periodically, once a minute by default. To change
this length of this period, use the logical OA$AIDA_QUOTA_INTERVAL.
For its value, specify the length, in seconds, of the monitor period
you want to use. For example, to set the monitor period to 90
seconds, define the logical name as follows:
$ DEFINE/SYSTEM/EXECUTIVE OA$AIDA_QUOTA_INTERVAL "90"
Define this value to "0" to suppress the quota monitoring tool
altogether.
The level of remaining resources required before messages are
logged is 5% by default, but this can be changed using the logical
OA$AIDA_QUOTA_WARNING_LEVEL. Values between 1 and 99 (inclusive)
are allowed. Out of range values will result in the default being
applied. After the message has been logged 5 times the logging is
turned off and a reply is issued to the ALL-IN-1 manager to warn
that the server is low on resources and that the log file should be
checked. This reply is issued once in every 10 times that the
monitor runs.
For example, to set the warning level to 10% , define the logical
name as follows:
$ DEFINE/SYSTEM/EXECUTIVE OA$AIDA_QUOTA_WARNING_LEVEL "10"
You will need to restart the AIDA Server for this change to become
effective.
INSTALLATION NOTES:
Before you install patch A1ADA_ECO01031, you must shut down ALL-IN-1.
Use the Shutdown ALL-IN-1 (SDA) option on the ALL-IN-1 Administration
menu (ADM) of the Management subsystem. This will automatically shut
down your sender and fetcher processes and all servers.
See the ALL-IN-1 Management Guide for more details. TeamLinks users
will be temporarily unable to access the ALL-IN-1 file cabinet.
There are several stages to installing an ALL-IN-1 IOS V3.1 patch
kit, which vary according to the configuration of the target system
and the contents of each patch kit.
There will always be a primary installation - typically supplying
revised object modules (.OBJs), revised script files (.SCPs) or
revised named data for ALL-IN-1 forms (.FRMs).
This patch kit supplies revised image files and therefore you will
need to perform a primary installation AND a second architecture
installation (if you have a mixed architecture VMScluster).
To install this patch, log into the SYSTEM account and use the
command procedure SYS$UPDATE:VMSINSTAL.COM as follows:
$ SET DEFAULT SYS$UPDATE
$ @VMSINSTAL A1ADA_ECO01031 'device'
where 'device' is the name of the device on which the distribution
medium will be mounted or the device:directory where you have already
copied the kit to.
When the installation has completed successfully repeat the above
procedure on your second architecture system (if you run ALL-IN-1 on
a mixed architecture VMScluster).
Once you have installed A1ADA_ECO01031, do the following:
Restart ALL-IN-1 by executing the following command
$ @SYS$STARTUP:A1V31START
If you run ALL-IN-1 on an Open VMScluster system, execute the
startup command procedure on every node of your VMScluster
where ALL-IN-1 is used.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
a1ada_eco01031.README
a1ada_eco01031.CHKSUM
a1ada_eco01031.CVRLET_TXT
a1ada_eco01031.a-dcx_axpexe
a1ada_eco01031.a-dcx_vaxexe
|