SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
RTR31D173 Reliable Transportation Router DIGITAL UNIX ECO Summary

Copyright (c) Digital Equipment Corporation 1998. All rights reserved. PRODUCT: Reliable Transaction Router for DIGITAL UNIX (RTR) OP/SYS: DIGITAL UNIX SOURCE: Digital Equipment Corporation ECO INFORMATION: ECO Kit Name: RTR31D173 ECO Kits Superseded by This ECO Kit: RTR31D_170 ECO Kit Approximate Size: 19807 Blocks (10141184 Bytes) TAR file - 19800 Blocks (10137600 Bytes) Kit Applies To: RTR V3.1D DIGITAL UNIX V3.2 through V4.0D System/Cluster Reboot Necessary: No ECO KIT SUMMARY: An ECO kit exists for Reliable Transaction Router on DIGITAL UNIX V3.2 through V4.0D. This kit addresses the following problems: Problems Addressed in RTR31D173: o A problem introduced in the 3.1D ECO1 (170) release that caused errors when using more than one partition has been corrected. The following restrictions apply to this kit: o The values for partition bounds are (as in previous versions) returned as binary values. A future version of RTR V3 will return these values as textual data. o An application's wakeup routine may be called more often than necessary. Problems Addressed in RTR31D_170: o A configuration including front end nodes running RTR V2 and router nodes running RTR V3.1D could result in an ACP failure with an assertion on the router node. This has been corrected. o The RTR ACP process would sometimes crash due to mis-handling of data pointers related to key range and facility information. The code has been changed to correct these problems. o The delivery of the RTR_EVTNUM_SRPRIMARY event sometimes arrived at an application in Shadow Secondary mode before the completion of the pending transaction, which potentially allowed the same transaction to be played to both shadow sites. This problem has been corrected by ensuring that the event is delivered only between transactions. o Following facility reconfiguration with the "trim facility" command, a situation could arise where a frontend node would be unable to connect to its own role as a router in a facility. Once in this mode, starting client channels would be unable to proceed past the state "wait_keyin". o The RTR Command Server process would sometimes crash while exiting because the shared memory segment required to print log file information was no longer available when the final flush of the log buffer occurred. This problem has been corrected. INSTALLATION NOTES: The Reliable Transaction Router Version 3.1D ECO2 installation procedure is the same as the installation procedure for RTR Version 3.1D.



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

rtr31d173.README
rtr31d173.CHKSUM
rtr31d173.CVRLET_TXT
rtr31d173.tar

privacy and legal statement