SEARCH CONTACT US SUPPORT SERVICES PRODUCTS STORE
United States    
COMPAQ STORE | PRODUCTS | SERVICES | SUPPORT | CONTACT US | SEARCH
gears
compaq support options
support home
software & drivers
ask Compaq
reference library
support forum
frequently asked questions
support tools
warranty information
service centers
contact support
product resources
parts for your system
give us feedback
associated links
.
} what's new
.
} contract access
.
} browse patch tree
.
} search patches
.
} join mailing list
.
} feedback
.
patches by topic
.
} DOS
.
} OpenVMS
.
} Security
.
} Tru64 Unix
.
} Ultrix 32
.
} Windows
.
} Windows NT
.
connection tools
.
} nameserver lookup
.
} traceroute
.
} ping
PLY_NETVIEW-OSF PNVECO01312 PLYCTR Mgr on Netview OSF/1 AXP 3.1B ECO Summary

Copyright (c) Digital Equipment Corporation 1995. All rights reserved. PRODUCT: POLYCENTER Manager on Netview Version 3.1B OP/SYS: DEC OSF/1 AXP SOURCE: Digital Equipment Corporation ECO INFORMATION: ECO Kit Name: PNVECO01312 ECO Kit Approximate Size: PNVECO01312.TAR 6225920 Bytes System Reboot Necessary: No ECO KIT SUMMARY: An ECO kit exists for POLYCENTER Manager on Netview for DEC OSF/1 AXP V3.1B. This kit addresses the following problems: Timestamps wrong in event history cards and historical event cards Timestamps in event history cards and historical event cards (event cards for events which occurred prior to bringing up the nvevents application) did not always match local time. When this occurred, the timestamps were usually one hour ahead. This problem has been fixed in ECO 01 for PNV 3.1B Closing subnet map windows caused the EUI to crash Closing subnet map windows could sometimes cause the EUI to crash. This problem has been fixed in ECO 01 for PNV 3.1B Netmon crashing repeatedly on unmanaged node with bad SNMP agent. Under certain circumstances, the SNMP access information for a node would never get initialized, causing netmon to crash repeatedly. When this occurred, the node causing the problem was unmanaged, and usually the SNMP agent on the node was passing bad SNMP data. Managing or deleting this particular node usually resolved the problem. This problem has been fixed in ECO 01 for PNV 3.1B Shpmon reporting artificially high swap space value on Digital UNIX V3.* Shpmon would report an artificially high swap space value on Digital UNIX V3.*. This problem has been fixed in ECO 01 for PNV 3.1B /usr/OV/prg_samples/nvsnmp_app/getTable program sample would fail on select() The program sample, /usr/OV/prg_samples/nvsnmp_app/getTable.c, did not initialize the I/O descriptor set before calling OVsnmpGetRetryInfo(). This could cause getTable to fail on select() call, under certain circumstances. This problem has been fixed in ECO 01 for PNV 3.1B



This patch can be found at any of these sites:

Colorado Site
Georgia Site



Files on this server are as follows:

pnveco01312.README
pnveco01312.CHKSUM
pnveco01312.tar

privacy and legal statement