MUXserver 380/320/90 MS8BASE_ECOV20D ULTRIX ECO Summary
Copyright (c) Digital Equipment Corporation 1995. All rights reserved.
PRODUCT: MUXserver 320/380/90 Remote Terminal Server, Version V2.0D
OP/SYS: ULTRIX
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: MS8BASE_ECOV20D
ECO Kits Superseded by This ECO Kit: MS8BASE_ECOV20C
ECO Kit Approximate Size: 4000 Blocks
Kit Applies To: ULTRIX V4.0 and above
System Reboot Necessary: No
ECO KIT SUMMARY:
An ECO kit exists for MUXserver 320, 380, 90 version 2.0 with load host
ULTRIX V4.0 and above. This kit addresses the following problems:
ECO # Description/Symptoms
===== ====================
V20A MUXserver 90 crashes due to heavy network load
MUXserver 90 backplane management protocol error
Hanging console port after link loopback test
Link locked at state Disconnecting
Failure in synchronous link loopback test for MUXserver 90
Link locked at state Connecting
Corrupted server queue entries
Removal of all references to software Baselevel
Synchronous link loopback test problems
Undefined Telnet port number
NULL character was stripped from Telenet connection
MUXserver 90 crashes after defining dedicated Telnet
service
Hanging print job from DSM
MUXserver 90 crashes with station limit exceeded
V20B Default port protocol was ignored
Telnet listener rejects second connection request
MUXserver 90 hanging link
MUXserver 90 crashes after setting the MUXserver link A
state to off
V20C MUXserver 320 crashes due to heavy network load
Link autobaud process failed with X.21 data-leads only
cable
LAT service problem
Failure in command test link x loopback external
Data loss on TELNET listener port
V20D Couldn't set ctrl/~ as a forward switch character
Crashes due to an incoming TCP/IP RST frame
Crashes with Telnet connection from other subnet
More than two Lat/Telnet gateway service definitions
INSTALLATION NOTES:
The system/cluster does not need to be rebooted after this kit is
installed. However, the MUXserver should be shutdown and restarted in
order for all kit changes to take effect.
For Ultrix:
Install the MUXserver 320/380/90 V2.0D ECO kit:
----------------------------------------------
# cd /
# setld -l /dv/rmtnh (where n is the unit number of the tape device)
Follow the questions as displayed. For more information, refer to the
MUXserver 320/380/90 Software Installation Guide (Ultrix).
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
ms8base_ecov20d.README
ms8base_ecov20d.CHKSUM
ms8base_ecov20d.CVRLET_TXT
ms8base_ecov20d.tar
|