SNALU62 SNALU62_V313 DIGITAL SNA APPC/LU6.2 V3.1 for Tru64 UNIX ECO Summary
TITLE: SNALU62 SNALU62_V313 DIGITAL SNA APPC/LU6.2 V3.1 for Tru64 UNIX ECO Summary
Copyright (c) Compaq Computer Corporation 1997, 1999. All rights reserved.
Modification Date: 16-FEB-99
Modification Type: Updated Kit Supersedes SNALU62_V312
PRODUCT: DIGITAL SNA APPC/LU6.2 Programming Interface V3.1
for Tru64 UNIX (formerly DIGITAL UNIX)
OP/SYS: Compaq Tru64 UNIX [R]
SOURCE: Compaq Computer Corporation
ECO INFORMATION:
ECO Kit Name: SNALU62_V313
ECO Kits Superseded by This ECO Kit: SNALU62_V312
ECO Kit Approximate Size: 8060 Blocks (4,126,720 bytes)
Kit Applies To: SNA APPC/LU6.2 Programming Interface for
Tru64 UNIX (formerly DIGITAL UNIX) V3.1
Compaq Tru64 UNIX V3.2C through V4.0x
System/Cluster Reboot Necessary: No
Installation Rating: N/A
NOTE: In order to receive the full fixes listed in this kit,
the following remedial kits also need to be installed:
None
INSTALLATION NOTE: This is not an update kit and the current
version of the LU6.2 Product must be deleted
before installing this ECO.
ECO KIT SUMMARY:
An ECO kit exists for DIGITAL SNA APPC/LU6.2 Programming Interface for
DIGITAL UNIX V3.1 on Tru64 UNIX (formerly DIGITAL UNIX) V3.2C through V4.0x.
The DEC SNA LU6.2 Programming Interface Release Notes contain a complete
explanation of this release. This kit addresses the following problems:
Problems Addressed in SNALU62_V313:
o Unable to access the LU6.2 Server Access Validation Files
o LU62 Config File May Not be Picked Up at lu62_server Startup
o SEGV Receiving a BIND
o Server Hang
o SEGV when deallocating the CP_LOCAL data structure
o Wrong error message TPNRET was returned
o Yacc table overflow
o BIND response without Control Vectors being rejected
Problems Addressed in SNALU62_V312:
o Pthread_cond_signal referenced deallocated context block
o SEGV occasionally occurs in lu62_manager when defining a local LU
o SEGV in lu62_config when display a local LU
o SEGV in lu62_manager when displaying a TP
o Server loops when receiving an inbound attach with security
information
Problems Addressed in SNALU62_V311:
o Use of Close option from window menu with Load/Parse and Save
Configuration
o LU-LU Session-Level Security Verification Failed
o Segmentation Faults When Session Was UNBOUND
o Virtual Memory Not Freed In CPIC When A Conversation Is In
Deallocate State
o Segmentation Faults When Trying to Free up a Buffer
o AS400 Adaptive Pacing Problem
o AS400 Fixed Pacing Problem
o Server hang if session unbound while conversation is active
o LU6.2 verbs may complete prematurely
o Unable to run server on TCP/IP hosts without a '.' in the name
o The cpic side file doesn't take the parameter security_type
o Attach manager information is missing from the configuration file
More information regarding the nature of these problems can be found in
the ECO kit's release notes.
INSTALLATION NOTES:
The ECO kit is distributed as a tar file containing the kit which can be
installed using the setld command. The tar file should be unpacked to a
suitable directory and then the setld command issued specifying that
directory as the source of the kit.
For example, if the tar file containing the kit has been copied to
/usr/tmp/snalu62313.tar:
# mkdir /usr/tmp/snalu62313
# cd /usr/tmp/snalu62313
# tar xf /usr/tmp/snalu62313.tar
# setld -l .
If the kit is delivered on tap11 then the commands would be:
# mkdir /usr/tmp/snalu62313
# cd /usr/tmp/snalu62313
# tar x
# setld -l .
Note that this is not an update kit, and the current version of the LU6.2
Product must be deleted before installing this ECO.
Once the kit is installed, you should follow the instructions in the
installation guide's After installation section.
[R] UNIX is a registered trademark in the United States and other
countries licensed exclusively through X/Open Company Limited
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
snalu62_v313.README
snalu62_v313.CHKSUM
snalu62_v313.CVRLET_TXT
snalu62_v313.tar
|