RTR31D173 Reliable Transportation Router DIGITAL UNIX ECO Summary
Copyright (c) Digital Equipment Corporation 1998. All rights reserved.
PRODUCT: Reliable Transaction Router for DIGITAL UNIX (RTR)
OP/SYS: DIGITAL UNIX
SOURCE: Digital Equipment Corporation
ECO INFORMATION:
ECO Kit Name: RTR31D173
ECO Kits Superseded by This ECO Kit: RTR31D_170
ECO Kit Approximate Size: 19807 Blocks (10141184 Bytes)
TAR file - 19800 Blocks (10137600 Bytes)
Kit Applies To: RTR V3.1D
DIGITAL UNIX V3.2 through V4.0D
System/Cluster Reboot Necessary: No
ECO KIT SUMMARY:
An ECO kit exists for Reliable Transaction Router on DIGITAL UNIX
V3.2 through V4.0D. This kit addresses the following problems:
Problems Addressed in RTR31D173:
o A problem introduced in the 3.1D ECO1 (170) release that caused
errors when using more than one partition has been corrected.
The following restrictions apply to this kit:
o The values for partition bounds are (as in previous
versions) returned as binary values. A future version of
RTR V3 will return these values as textual data.
o An application's wakeup routine may be called more often
than necessary.
Problems Addressed in RTR31D_170:
o A configuration including front end nodes running RTR V2 and
router nodes running RTR V3.1D could result in an ACP failure with an
assertion on the router node. This has been corrected.
o The RTR ACP process would sometimes crash due to mis-handling
of data pointers related to key range and facility information. The
code has been changed to correct these problems.
o The delivery of the RTR_EVTNUM_SRPRIMARY event sometimes
arrived at an application in Shadow Secondary mode before the
completion of the pending transaction, which potentially allowed the
same transaction to be played to both shadow sites. This problem has
been corrected by ensuring that the event is delivered only between
transactions.
o Following facility reconfiguration with the "trim
facility" command, a situation could arise where a frontend node would
be unable to connect to its own role as a router in a facility. Once
in this mode, starting client channels would be unable to proceed past
the state "wait_keyin".
o The RTR Command Server process would sometimes crash while
exiting because the shared memory segment required to print log file
information was no longer available when the final flush of the log
buffer occurred. This problem has been corrected.
INSTALLATION NOTES:
The Reliable Transaction Router Version 3.1D ECO2 installation
procedure is the same as the installation procedure for RTR Version 3.1D.
This patch can be found at any of these sites:
Colorado Site
Georgia Site
Files on this server are as follows:
rtr31d173.README
rtr31d173.CHKSUM
rtr31d173.CVRLET_TXT
rtr31d173.tar
|