 * IBM ServeRAID Device Drivers for SCO Operating Systems            *
 * Version 3.50                                                      *
 *********************************************************************

  This README file contains instructions for installing the IBM
  ServeRAID device driver and Background Server component for SCO
  OpenServer and UnixWare operating systems.  The IBM ServeRAID Device
  Drivers for SCO Operating Systems Diskette contains the following:

    o  Device drivers and the background server component for SCO
       OpenServer 5.0.0, 5.0.2, 5.0.4, and 5.0.5.

    o  Device drivers and the background server component for SCO
       UnixWare 7.0.x and 7.1.x

     NOTE:
     See the README file on the "IBM ServeRAID BIOS/Firmware Update
     diskette" for descriptions of the current ServeRAID diskettes
     and for detailed information about the changes and enhancements
     provided with each version.

  For more information about IBM ServeRAID and server products, visit
  http://www.pc.ibm.com/support

  ____________________________________________________________
  CONTENTS
  ________

  1.0  About this Diskette
  2.0  Installing the Files for SCO OpenServer
  ... 2.10  Adding BTLD at Boot Time
  ... 2.20  Adding BTLD after the Initial Installation
  ... 2.30  Using an IDE CD-ROM Drive to Install OpenServer Files
  3.0  Installing the Files for UnixWare
  ... 3.10  Installing the Files while Installing UnixWare
  ... 3.20  Installing the Files after Installing UnixWare
  4.0  Starting the Background-Server Component
  5.0  Trademarks and Notices


  _____________________________________________________________________
  1.0  About this Diskette
  ________________________

  To use the ServeRAID Administration and Monitoring Program with SCO,
  you must first install the WIN32-Based version of the Administration
  and Monitoring Program on a Windows NT or Windows 95 client.  Then,
  attach the Windows NT or Windows 95 client to the same network as
  the OpenServer or UnixWare systems that contain the ServeRAID
  adapters or controllers.  Finally, you must install the ServeRAID
  OpenServer or UnixWare device driver and background-server
  component.

  The background-server component for the OpenServer and UnixWare
  operating systems install automatically when you install the
  ServeRAID OpenServer or UnixWare device drivers.

  ____________________________________________________________________
  2.0  Installing the Files for SCO OpenServer
  ____________________________________________

  Before you begin the installation, review the following information:

  o   You must install logical drives as Bus Number 0 when using the
      MKDEV program, regardless of the channel that the physical
      drives are on.

  o   You must install nondisk devices, such as CD-ROM and tape
      drives, as Bus Numbers 1, 2, or 3 relative to the channel to
      which they are attached.  External Channel 1 connector is Bus
      Number 1, external Channel 2 connector is Bus Number 2, and
      internal Channel 3 connector is Bus Number 3.

  To configure the default nondisk devices during the initial
  installation:

  1.  Redefine the default tape drive in the initial bootstring.
      For example, to install the IPSRAID BTLD and redefine the tape
      drive, go to the "BOOT" prompt and type:

        link Stp=ips(0, 1, 2, 0)

      The numbers in parentheses represent the Host Adapter Number,
      the Bus Number, the SCSI ID, and the LUN respectively.

  2.  When prompted for the location of the installation CD,
      change the Bus Number and SCSI ID, as required.


  2.10  Adding BTLD at Boot Time
  ------------------------------

  To install the ServeRAID device driver for OpenServer, Version
  5.0.X:

  1.  At the "BOOT" prompt, type:

        link

  2.  Press ENTER; then, when asked for the name of the package to
      load, type:

        ipsraid

  3.  Press ENTER.

  4.  After the kernel loads but before it runs, "link" prompts
      you to insert the IBM ServeRAID Device Drivers for SCO Operating
      Systems Diskette.

      While the installation program copies the files, one or both of
      the following messages might appear:

      MESSAGES:

      a.  "Extracting BTLD distribution for ipsraid...
          /etc/uadmin getdev b ips:  No such device (error 19)"

      b.  "dynamic linker:  dlvr_audit:  Cannot open /dev/zero for
          file /lib/libprot.so.1 "

      You can ignore Message A, no action is required.  But if Message
      B appears, you must press ENTER when prompted to continue the
      installation.

  5.  Keep the IBM ServeRAID Device Drivers for SCO Operating
      Systems Diskette readily available.  You will need it to
      configure the device driver into the link kit.

  For additional information about adding a BTLD at boot time, refer
  to "Using Boot-Time Loadable Drivers" in the SCO OpenServer
  Handbook.

  2.20  Adding BTLD after the Initial Installation
  ------------------------------------------------

  1.  Start the server in system maintenance mode, and log in as root.

  2.  Type:

        installpkg

  3.  Press ENTER; then, select the diskette drive in which you
      will insert your installation diskette.

  4.  Insert the IBM ServeRAID Device Drivers for SCO Operating
      Systems Diskette, when prompted.

  5.  When prompted for the name of the package, type:

        ipsraid

  6.  Press ENTER; then, relink the kernel (as described in
      "Relinking the kernel" in the SCO OpenServer Handbook) by
      entering the following commands:

        cd /etc/conf/cf.d
        ./link_unix

  7.  After the kernel rebuilds, the following message appears:

      "The UNIX kernel has been rebuilt.  Do you want this kernel to
      boot by default?  "

      To continue, enter:  "y"

      The system backs up the old kernel by moving /UNIX to /UNIX.OLD.

  8.  When the system asks for the kernel environment to be
      rebuilt, enter:  "y"

      The system will respond with a successful message.

  9.  Use shutdown to bring down the system; then, restart the
      system.


  2.30  Using an IDE CD-ROM Drive to Install OpenServer Files
  -----------------------------------------------------------

  This section contains instructions for installing files for
  OpenServer 5.0.0, OpenServer 5.0.2, and OpenServer 5.0.4 when using
  an IDE CD-ROM Drive.

  Installing the Files for OpenServer 5.0.0

  To install files for OpenServer 5.0.0 using an IDE CD-ROM drive:

  1.  Type the following at the "BOOT" prompt:

        restart ahslink="ATAPI ipsraid" Srom=wd(0,0,0,0)

  2.  Insert the ATAPI BTLD diskette when prompted; then, press R
      to replace the wd driver.

      The fields for the ATAPI CDROM are:

      Srom=wd(c,d,l,b) where:

          c = primary (0) or secondary (1) IDE/EIDE controller

          d = master (0) or slave (1) device

          l = LUN of device (always 0 with ATAPI or wd driver)

          b = BUS of device (always 0 with ATAPI or wd driver)


  Installing the Files for OpenServer 5.0.2 and 5.0.4

  To install files for OpenServer Versions 5.0.2 or 5.0.4 using an IDE
  CD-ROM drive:

  1.  Type the following at the "BOOT" prompt:

        restart link=ipsraid Srom=wd(0,0,0,0)

      NOTE:  The ATAPI BTLD (which includes the wd driver) is
             included in OpenServer 5.0.2 and 5.0.4.

      The fields for the ATAPI CDROM are:

      Srom=wd(c,d,l,b) where:

          c = primary (0) or secondary (1) IDE/EIDE controller

          d = master (0) or slave (1) device

          l = LUN of device (always 0 with ATAPI or "wd" driver)

          b = BUS of device (always 0 with ATAPI or "wd" driver)

  2.  Let the system start normally until it comes to the select
      Media options.

      o   If you are using OpenServer 5.0.2, go to step 3.

      o   If you are using OpenServer 5.0.4, go to step 4.

  3.  To install with OpenServer 5.0.2:

      a.  Select Adapter type as WD.
      b.  Select Media Type as SCSI CDROM.
      c.  Select ID, BUS and LUN as 0.
      d.  Go to step 5.

  4.  To install with OpenServer 5.0.4:

      a.  Select Media Type as IDE CDROM DRIVE.
      b.  Select PRIMARY ADAPTER and MASTER DEVICE.
      c.  Go to step 5.

  5.  You have completed the installation.


  ___________________________________________________________________
  3.0  Installing the Files for UnixWare
  ______________________________________

  The instructions for installing the ServeRAID files when using
  UnixWare depend on the number of IDE and SCSI disk-storage adapters
  and controllers installed in the system.  If all of the
  direct-access-storage devices (DASD) in the system are attached to a
  single disk-storage adapter or controller (such as the ServeRAID
  adapter or controller), you can skip the instructions in this
  section and go directly to "Installing the Files while Installing
  UnixWare"  or "Installing the Files after Installing
  UnixWare" section.

  If you are attaching devices to multiple disk-storage adapters or
  controllers (including IDE and SCSI controllers integrated on the
  system board), use the following instructions.

  o   If you are installing UnixWare on a drive attached to a
      ServeRAID adapter or controller, follow the instructions in
      "Installing UnixWare on a ServeRAID Drive".

  o   If you are installing UnixWare on a drive attached to a
      non-ServeRAID adapter or controller and you intend to store only
      data on the drives attached to your ServeRAID adapters and
      controllers, follow the instructions in "Installing UnixWare on
      a Non-ServeRAID Drive."

  INSTALLING UNIXWARE ON A SERVERAID DRIVE:  Use the following
  instructions if you are using multiple disk-storage adapters or
  controllers and you are installing UnixWare on a drive attached to a
  ServeRAID adapter or controller.

  NOTE:  If you are not using multiple disk-storage adapters and
         controllers, go to "Installing the Files while Installing
         UnixWare" in section 3.10.

  1.  Install all ServeRAID adapters that you intend to use in
      your system.

  2.  Using the ServeRAID Configuration Program, create all of
      your arrays and define all of your logical drives.

  3.  Make a list of all of the ServeRAID adapters and
      controllers, including the order and slot number, installed in
      the system.  To do this:

      a.  Turn on the server.

      b.  When the ServeRAID Mini-Configuration prompt appears,
          press CTRL+I.  When a system contains more than one
          ServeRAID adapter or controller, a selection screen appears.

      c.  The menu lists the ServeRAID adapters and controllers in
          order.  Select the first ServeRAID adapter or controller
          from the menu.

      d.  Select ADVANCED FUNCTIONS from the Main Menu.

      e.  Select VIEW CONTROLLER AND PCI INFORMATION from the
          Advanced Functions menu.

      f.  Record the slot number for the ServeRAID adapter or
          controller; then, press ESC three times to return to the
          controller selection screen.

      g.  Select the next adapter or controller and repeat steps 3d
          through step 3f until you record the slot number for each
          ServeRAID adapter or controller that appears on the
          selection screen.

  4.  Turn off the system; then, remove all ServeRAID adapters and
      controllers except the first one on your list.

      NOTE:  If one of the ServeRAID controllers that you need
             to remove is on the system board, you must do one of the
             following:

             o   If the CD-ROM drive that you are using to install
                 your operating system is attached to the integrated
                 ServeRAID controller, disconnect or remove all disk
                 drives attached to the integrated controller.

             o   If only disk drives are attached to the integrated
                 controller, disconnect the SCSI cable from the
                 ServeRAID connector on the system board.  See the
                 label inside the server cover for the location of the
                 ServeRAID connector.

  5.  Remove all other non-ServeRAID IDE and SCSI disk-storage
      adapters and controllers.

      NOTE:  If one of the disk-storage controllers that you
             need to remove is on the system board, you must do one of
             the following:

             o   If the CD-ROM drive that you are using to install
                 your operating system is attached to the integrated
                 disk-storage controller, disconnect or remove all
                 disk drives attached to the integrated controller.

             o   If only disk drives are attached to the integrated
                 controller, disconnect the cable for the integrated
                 controller from the IDE or SCSI connector on the
                 system board.  See the label inside the server cover
                 for the location of the IDE or SCSI controller
                 connector.

  6.  Follow the instructions in "Installing the Files while
      Installing UnixWare" in section 3.10; then, return here and
      continue with step 7.

  7.  Power down the system.

  8.  Install any non-ServeRAID disk-storage adapters or
      controllers in the server; then, attach the drives to the
      disk-storage adapters and controllers.

  9.  Install the next ServeRAID adapter or controller from the
      list you created in step 3f; then, attach the drives to the
      ServeRAID adapter or controller.

  10.  Turn on the system and allow UnixWare to discover the new
      disk-storage adapters and controllers.

  11. Power down the system.

  12. Repeat steps 9, 10, and 11 until all ServeRAID adapters,
      ServeRAID controllers, and drives are installed.

  13. You can now partition and format the logical drives
      attached to the additional ServeRAID adapters and controllers.
      See the information provided with UnixWare for more
      instructions.

  INSTALLING UNIXWARE ON A NON-SERVERAID DRIVE:  Use the instructions
  in this section if you are using multiple disk-storage adapters or
  controllers, you are installing UnixWare on a drive attached to a
  non-ServeRAID adapter or controller, and you intend to store only
  data on the drives attached to your ServeRAID adapters and
  controllers.

  1.  Install all ServeRAID adapters that you intend to use in
      your system.

  2.  Using the ServeRAID Configuration Program, create all of
      your arrays and define all of your logical drives.

  3.  Make a list of all of the ServeRAID adapters and controllers,
      including the order and slot number, installed in the system.
      To do this:

      a.  Turn on the server.

      b.  When the ServeRAID Mini-Configuration prompt appears,
          press CTRL+I.  When a system contains more than one
          ServeRAID adapter or controller, a selection screen appears.

      c.  The menu lists the ServeRAID adapters and controllers in
          order.  Select the first ServeRAID adapter or controller
          from the menu.

      d.  Select ADVANCED FUNCTIONS from the Main Menu.

      e.  Select VIEW CONTROLLER AND PCI INFORMATION from the Advanced
          Functions menu.

      f.  Record the slot number for the ServeRAID adapter or
          controller; then, press ESC three times to return to the
          controller selection screen.

      g.  Select the next adapter or controller and repeat steps 3d
          through step 3f until you record the slot number for each
          ServeRAID adapter or controller that appears on the
          selection screen.

  4.  Turn off the system; then, remove all ServeRAID, IDE, and SCSI
      disk-storage adapters and controllers except the one attached to
      the drive where you intend to install UnixWare.

      NOTE:  If one of the disk-storage or ServeRAID
             controllers that you need to remove is on the system
             board, do one of the following:

             o   If the CD-ROM drive that you are using to install
                 your operating system is attached to the integrated
                 controller, disconnect or remove all disk drives
                 attached to the integrated controller.

             o   If only disk drives are attached to the integrated
                 controller, disconnect the SCSI or IDE cable for the
                 integrated controller from the connector on the
                 system board.  See the label inside the server cover
                 for the location of the SCSI and IDE cable
                 connectors.

  5.  Follow the instructions in "Installing the Files while
      Installing UnixWare" in section 3.10; then, return here and
      continue with step 6.

  6.  Power down the system.

  7.  Install any non-ServeRAID disk-storage adapters or controllers
      in the server; then, attach the drives to the disk-storage
      adapters and controllers.

  8.  Install the first ServeRAID adapter or controller from the list
      you created in step 3f; then, attach the drives to the ServeRAID
      adapter or controller.

  9.  Turn on the system and allow UnixWare to discover the new
      disk-storage adapters and controllers.

  10. Power down the system.

  11. Install the next ServeRAID adapter or controller from the list
      you created in step 3f; then, attach the drives to the ServeRAID
      adapter or controller.

  12. Repeat steps 9, 10, and 11 until all ServeRAID adapters,
      ServeRAID controllers, and drives are installed.

  13. You can now partition and format the logical drives
      attached to the ServeRAID adapters and controllers.  See the
      information provided with UnixWare for more instructions.


  3.10  Installing the Files while Installing UnixWare
  ----------------------------------------------------

  To install the ServeRAID files while installing UnixWare 7.0:

  1.  Use the instructions provided with UnixWare to begin the
      installation.

  2.  When a message appears asking if you want to install any HBA
      diskettes, insert the IBM ServeRAID Device Drivers for SCO
      Operating Systems Diskette; then, select INSTALL HBA DISKETTE.

  3.  Use the instructions provided in the UnixWare manual to
      complete the normal installation process.


  3.20  Installing the Files after Installing UnixWare
  ----------------------------------------------------

  Use the following instructions to install the ServeRAID files after
  you install UnixWare, or use these instructions to update a
  previously installed ServeRAID file with a newer version.  You can
  use the UnixWare Pkgadd or the UnixWare SCOAdmin utility program to
  install the files.

  INSTALLING AN HBA DISKETTE FILE USING PKGADD

  1.  Insert the IBM ServeRAID Device Drivers for SCO Operating
      Systems Diskette into the diskette drive.

  2.  Type:

        pkgadd -d /dev/dsk/f0t

  3.  Press ENTER

  4.  When the message "Insert diskette into Floppy Drive 1"
      appears, press ENTER.

  5.  When the message "Installation of IBM ServeRAID SCSI IHV HBA
      (ips) was successful" appears, type:

        q

  6.  Press ENTER; then after the device driver installs, restart
      the system.

  INSTALLING AN HBA DISKETTE FILE USING SCOADMIN

  1.  Insert the IBM ServeRAID Device Drivers for SCO Operating
      Systems Diskette into the diskette drive.

  2.  Start the SCOAdmin utility program.

  3.  Select SOFTWARE_MANAGEMENT.

  4.  Select APPLICATION INSTALLER.

  5.  Select DISK_A from the Install From tab.

  6.  Click on the UPDATE VIEW button.

  7.  When the icon labeled IPS appears in the window, click on
      INSTALL.

  8.  After the device driver installs, restart the system.


  ____________________________________________________________________
  4.0  Starting the Background-Server Components
  ______________________________________________

  To start the background-server components for SCO OpenServer and
  and UnixWare:

  1.  Make sure you are logged on as "root".

       a.  If you are not, type:

           su

       b.  When prompted, enter the "root" password.

  2.  Start the background-server component (daemon) running
      in the background.  To do this, type:

      ipsadm &

  3.  Press ENTER.


  ____________________________________________________________________
  5.0  Trademarks and Notices
  ___________________________

   The following terms are trademarks of the IBM Corporation in the
   United States or other countries or both:

   IBM      Netfinity      ServeRAID


   Microsoft, Windows, and Windows NT are trademarks or registered
   trademarks of Microsoft Corporation.

   UNIX is a registered trademark in the United States and other
   countries licensed exclusively through X/Open Company Limited.

   Other company, product, and service names may be trademarks
   or service marks of others.

   THIS DOCUMENT IS PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND.  IBM
   DISCLAIMS ALL WARRANTIES, WHETHER EXPRESS OR IMPLIED, INCLUDING
   WITHOUT LIMITATION, THE IMPLIED WARRANTIES OF FITNESS FOR A PARTICULAR
   PURPOSE AND MERCHANTABILITY WITH RESPECT TO THE INFORMATION IN THIS
   DOCUMENT.  BY FURNISHING THIS DOCUMENT, IBM GRANTS NO LICENSES TO ANY
   PATENTS OR COPYRIGHTS.

   Note to U.S. Government Users -- Documentation related to restricted
   rights -- Use, duplication or disclosure is subject to restrictions
   set forth in GSA ADP Schedule Contract with IBM Corp.