NOVELL TECHNICAL INFORMATION DOCUMENT TITLE: Post NW51sp6 cpqarray drivers TID #: 2966524 README FOR: cpqarray.exe NOVELL PRODUCTS and VERSIONS: NetWare 5.1 ABSTRACT: The Novell Consolidated Support Pack 9 (CSP 9), which includes NetWare 5.1 Support Pack 6 (SP 6), erroneously installs version 2.16 of the 32-Bit Array Controller Driver for Novell NetWare (CPQARRAY.HAM). CPQARRAY.HAM Version 2.16 may appear to run normally on the server, but it was not designed for (or tested with) NetWare 5.1 and should not be used in this configuration. Note: CPQARRAY.HAM Version 2.09 is the correct version to be used with NetWare 5.1. 7/17/03 updated documentation ----------------------------------------------------------------- DISCLAIMER THE ORIGIN OF THIS INFORMATION MAY BE INTERNAL OR EXTERNAL TO NOVELL. NOVELL MAKES ALL REASONABLE EFFORTS TO VERIFY THIS INFORMATION. HOWEVER, THE INFORMATION PROVIDED IN THIS DOCUMENT IS FOR YOUR INFORMATION ONLY. NOVELL MAKES NO EXPLICIT OR IMPLIED CLAIMS TO THE VALIDITY OF THIS INFORMATION. ----------------------------------------------------------------- INSTALLATION INSTRUCTIONS: You may use NWCONFIG to install this patch. NWCONFIG 1. Load NWCONFIG | Product Options | Install a product no listed | 2. Choose F3 to specify a different path and point path to the "cpqarray.ips" file in the patch cpqacpi directory. 3. Select F10 to accept. 4. When patch is complete, you will need to down and restart your server for changes to take effect. ISSUE: SCOPE Any ProLiant server that contains a Smart Array Controller, is running NetWare 5.1, and is receiving (or requiring) an installation of the Novell Consolidated Support Pack 9. RESOLUTION To avoid installing version 2.16 of the 32-Bit Array Controller Driver for Novell NetWare (CPQARRAY.HAM) during the installation of CSP 9, select to NOT update the hardware device drivers. HARDWARE PLATFORMS AFFECTED: ProLiant 1600, ProLiant 1850R, ProLiant 3000, ProLiant 400, ProLiant 5500, ProLiant 6400R, ProLiant 800, ProLiant 8000, ProLiant 8500, ProLiant CL1850, ProLiant CL380, ProLiant DL360, ProLiant DL360 G2, ProLiant DL360 G3, ProLiant DL380, ProLiant DL380 G2, ProLiant DL380 G2 Packaged Cluster, ProLiant DL380 G3, ProLiant DL380 G3 Packaged Cluster, ProLiant DL560, ProLiant DL580, ProLiant DL580 G2, ProLiant DL760, ProLiant ML310, ProLiant ML330, ProLiant ML330 G2, ProLiant ML330e, ProLiant ML350, ProLiant ML350 G2, ProLiant ML350 G3, ProLiant ML370, ProLiant ML370 G2, ProLiant ML370 G3, ProLiant ML530, ProLiant ML530 G2, ProLiant ML570, ProLiant ML570 G2, ProLiant ML750 COMPONENTS AFFECTED: Integrated Smart Array Controller, Smart Array 221 Controller, Smart Array 3100ES RAID Controller, Smart Array 3200 Controller, Smart Array 4200 Controller, Smart Array 4250ES Controller, Smart Array 431 Controller Self-Extracting File Name: cpqarray.exe Files Included Size Date Time ..\ CPQARRAY.TXT (This file) ..\CPQARRAY\ CPQARRAY.DDI 9020 5-11-2000 7:00:00 am CPQARRAY.HAM 90589 2-28-2001 3:09:00 am CPQARRAY.IPS 131 6-11-2003 2:54:24 pm ----------------------------------------------------------------- Any trademarks referenced in this document are the property of their respective owners. Consult your product manuals for complete trademark information. -----------------------------------------------------------------