SUMMARY
This article contains information on the documentation errors in the
"User's Guide," MS-DOS Help, "Technical Reference," VSAFE Help,
Microsoft Anti-Virus Help, and Defrag help.
The following topics are covered:
"User's Guide" Errors
- To obtain a user identification code for the BBS
- Page 160 "To Free Enough Conventional Memory to Run MemMaker"
- English (International) Keyboard Code Listed as "+"
- Page 163: "<Double Buffering>"
- BUSETUP Runs from Drive A Only
- Page 104: Holding SHIFT at Startup Displays a Message
MS-DOS 6 Help Errors
- Backup does not Support Automatic/Regular Basis Backups
- EMM386 Page Frame (Pn=) Valid Range is not 0 through 255
- Incomplete List of Files Copied with FORMAT /S
- Incomplete List of Files Copied with SYS command
- Online Help Incorrectly Defines MSAV Check All Files
- Online Help Gives Incorrect LASTDRIVE Default Value
- Question Mark After Blank Space Results in Error Message
- MS-DOS 6 Help for SMARTDrive (BufferSize)
- Error in MS-DOS Help Example for the MENUCOLOR Command
- PRINT Command /S: <ticks3> Switch
- Setup /I Disables Video Detection Only, Not Hardware Detection
- Incorrect Statement Regarding VERIFY
Microsoft "User's Guide" and MS-DOS 6 Help Errors
- NUMLOCK Is Independent of Other Multiple-Configuration Commands
- DMA Default Value Is 32
"Technical Reference" Errors
- "Technical Reference" - Page 3
- "Technical Reference" - Page 13, Incorrect Compression Example
- "Technical Reference" - Page 14 "A CVF Is Just a Hidden, Read-Only
File..."
- "Technical Reference" - Page 32
- "Technical Reference" - Page 177
- "Technical Reference" - Page 229, Incomplete List of Files Copied
with FORMAT /S
- "Technical Reference" - Page 341, Incomplete List of Files Copied
with SYS command
- "Technical Reference" - Page 347, Incorrect Value for SENTRY Directory
- "Technical Reference" - Page 353, Incorrect Statement Regarding VERIFY
MS-DOS Utilities Online Help Errors
- Defrag Help - FULL OPTIMIZE with MS-DOS Defragmenter (Defrag)
- DoubleSpace Help: Drive Letter Memory Use Is Listed Incorrectly
- Undelete Help: Incomplete
- VSAFE Help: Incorrect VSAFE Memory Requirement
- Anti-Virus Help: Incorrect Help Text
- Anti-Virus Help: Misleading Help Text for /S Switch
- MS Backup for Windows Help: Command-Line Syntax Error
- Interlnq Help: Pinout Chart Is Incorrect
- Undelete: Incorrect Value for SENTRY Directory
"USER'S GUIDE" ERRORS
"To obtain a user identification code for the BBS"
On page 277 of the MS-DOS 6 User's Guide (has the Roadmap book cover) and
page 255 of the MS-DOS User's Guide (has the MS-DOS logo book cover), the
procedure "To obtain a user identification code for the BBS" states in step
2 to call (503) 531-8100 to obtain a user identification code in order to
download the most recent Microsoft Anit-Virus signatures.
Indentification codes are no longer required to obtain Microsoft Anti-Virus
signatures. To obtain the most recent Microsoft Anti-Virus signtures, call
Central Point Software BBS at (503) 984-5366.
Page 160 "To Free Enough Conventional Memory to Run MemMaker"
On page 160 of the "User's Guide," the procedure titled "To free
enough conventional memory to run MemMaker" includes an error in step
4. You are instructed to bypass all but the following commands in the
CONFIG.SYS file:
HIMEM.SYS
EMM386.EXE
SHELL
If you bypass the command line loading CHKSTATE.SYS, the error message
is displayed and the procedure fails. To make this procedure work
correctly, make sure you do not bypass CHKSTATE.SYS.
English (International) Keyboard Code Listed as "+"
Page 237 of the "User's Guide" incorrectly implies that the keyboard
code for English (International) is the PLUS SIGN (+) character.
There is no two-character keyboard code used for English
(International); you simply use the default U.S. keyboard.
The PLUS SIGN is used in the "User's Guide" to indicate that there is
no separate international keyboard for English (International).
"User's Guide" Page 163: "<Double Buffering>"
On page 163 of the "User's Guide," the fifth bullet in the section
"Streamlining Your CONFIG.SYS and AUTOEXEC.BAT Files" uses the term
"<double buffering>."
It should say "<SMARTDRV.EXE>."
BUSETUP Runs from Drive A Only
Page 5 of the "User's Guide" indicates that you can use the BUSETUP /E
command to install the optional utilities from either drive A or drive
B.
This information is incorrect, you can run BUSETUP from drive A only.
Page 104: Holding SHIFT at Startup Displays a Message
Page 104 of the "MS-DOS 6 User's Guide" incorrectly states that
holding down the SHIFT key (to perform a Clean Start) causes the
following message to be displayed:
MS-DOS is bypassing your CONFIG.SYS and AUTOEXEC.BAT files.
Although MS-DOS does bypass your CONFIG.SYS and AUTOEXEC.BAT files, it
does not display the above message when you hold down the SHIFT key.
This message is displayed only when you press the F5 key.
MICROSOFT MS-DOS 6 HELP ERRORS
Backup Does Not Support Automatic/Regular Basis Backups
MS-DOS 6.0 Help states the following:
You can back up all files on a disk or files that have changed since
your last backup, schedule backups so they are done automatically on a
regular basis, and restore files that you have backed up.
This is incorrect. You cannot "schedule backups so they are done
automatically on a regular basis" with Microsoft Backup.
EMM386 Page Frame (Pn=) Valid Range Is Not 0 Through 255
Help incorrect states zero (0) through 255 is the valid range for the
Pn= parameter. The valid parameters for Pn= are 0, 1, 2, 3, 254, and
255.
Incomplete List of Files Copied with FORMAT /S
The explanation of the FORMAT command indicates that issuing the
command with the /S switch copies the IO.SYS, MSDOS.SYS, and
COMMAND.COM files from your system startup drive to your newly
formatted disk.
In addition to the files indicated, FORMAT /S copies the DBLSPACE.BIN
file to your newly formatted disk.
Incomplete List of Files Copied with SYS Command
The explanation of the SYS command indicates that issuing the command
creates a startup disk by copying the IO.SYS, MSDOS.SYS, and
COMMAND.COM files from your system startup drive to your newly
formatted disk.
In addition to the files indicated, SYS copies the DBLSPACE.BIN file
to the startup disk.
Online Help Incorrectly Defines MSAV Check All Files
In the Notes section of Microsoft Anti-Virus Help, the Check All Files
option is incorrectly described as follows:
When the Check All Files option is selected, Anti-Virus for MS-DOS
checks only files with the following extensions: .386, .APP, .BIN,
.CMD, .DOM, .DLL, .DRV, .EXE, .FON, .ICO, .OV*, .PGM, .PIF, .PRG,
.SYS.
It should state that only files with those extensions are checked when
this option is NOT selected. When this option is selected, ALL files
are checked for viruses.
Online Help Gives Incorrect LASTDRIVE Default Value
The Notes section of LASTDRIVE Help incorrectly describes the default
value for LASTDRIVE as "the letter following the last one in use."
It should state that the default value for LASTDRIVE is E: or the last
drive specification in use.
Question Mark After Blank Space Results in Error Message
According to MS-DOS Help, you can insert a question mark character (?)
just before the equal sign (=) to specify that MS-DOS is to ask for
confirmation before carrying out the command.
This works correctly as long as there are no spaces or parameters
between the command and the question mark character.
For example, DEVICE?=C:\DOS\ANSI.SYS causes the following prompt to be
displayed:
DEVICE=C:\DOS\ANSI.SYS [Y,N]?
However, if you have DEVICEHIGH /L:1,12048 ?=C:\DOS\ANSI.SYS, you
receive the following error message:
Bad or Missing ?
Error in CONFIG.SYS line <number>
Similarly, the command DOS ?=HIGH results in an error message.
To use the question mark character properly, place the question mark
character immediately after the command, not immediately before the
equal sign. For example:
DEVICEHIGH? /L:1,12048 =C:\DOS\ANSI.SYS
DOS? = HIGH
MS-DOS 6 Help for SMARTDrive (BufferSize)
The help text for SMARTDrive under /B:BufferSize says:
If an application reads 512K of information..."
It should state:
" If an application reads 512 bytes of information..."
Error in MS-DOS Help Example for the MENUCOLOR Command
If you are using an MS-DOS 6.0 multiple-configuration menu and you set
the MENUCOLOR command in the CONFIG.SYS file to match the example
shown in MS-DOS Help, the menu color does not display.
The example in MS-DOS Help shows a space after the comma, which causes
MS-DOS to stop reading the MENUCOLOR command when the CONFIG.SYS file
is processed. As a result, the menu color is not displayed.
To work around this problem, remove the space after the comma.
PRINT Command /S: <ticks3> Switch
The explanation for the MS-DOS PRINT command switch /S:<ticks3> on
in the Microsoft on-line Help incorrectly states the following:
Increasing this value can speed up printing while slowing down
other programs.
The <ticks3> value actually represents the CPU time (expressed in
time-slice ticks) that passes before PRINT.EXE can use a tick to send
characters to the printer. If you increase this value, printing slows
because more of the CPU time is allotted to tasks other than printing.
For example, if you set this value to 25, PRINT.EXE must wait 25 ticks
before it can use one tick's worth of time to send characters to the
printer. A smaller value for the /S switch gives PRINT.EXE more of the
CPU cycle and therefore speeds up printing.
Setup /I Disables Video Detection Only, Not Hardware Detection
The Setup /I switch is documented incorrectly. When you use the /?
parameter, Setup displays the following:
SETUP [/B] [/E] [/F] [/G [/H]] [/I] [/M] [/Q] [/U]
/B Displays Setup screens in monochrome instead of color.
/E Installs Windows and MS-DOS optional programs.
/F Installs a minimal MS-DOS 6 system on a floppy disk.
/G Does not create the Uninstall Disk and does not prompt
you when you need to update your network.
/H Uses default Setup options.
/I Turns off hardware detection.
/M Installs a minimal MS-DOS 6 system.
/Q Copies MS-DOS files to a hard disk.
/U Installs MS-DOS even if Setup detects disk partitions
that might be incompatible with MS-DOS 6.
Setup /I disables video detection only. To disable video detection and
hardware detection (including FastDisk compatibility detection
[borrowed from Windows Setup]), use the /I and /U parameters.
Incorrect Statement Regarding VERIFY
The VERIFY section of MS-DOS Help incorrectly states:
You can use VERIFY either from the command line or the CONFIG.SYS.
The correct statement is:
You can use VERIFY from the command line or the AUTOEXEC.BAT.
"USER'S GUIDE" AND MICROSOFT MS-DOS 6 HELP ERRORS
NUMLOCK Is Independent of Other Multiple-Configuration Commands
Both the "User's Guide" and MS-DOS Help document the NUMLOCK command
as a special CONFIG.SYS command for defining startup menus and
multiple configurations. Although NUMLOCK is valid in multiple
configurations, it can be used independent of multi-config commands.
The "User's Guide," Appendix A, page 249 states the following:
NUMLOCK
Specifies whether the NUMLOCK setting on your numeric keypad is set
to ON or OFF. You can use this command only within a menu block in
your CONFIG.SYS file.
The first sentence above is correct; the second sentence is not.
NUMLOCK is a valid command anywhere in your CONFIG.SYS file.
MS-DOS Help (accessed by typing
help numlock at the MS-DOS command prompt) states the following:
Related Commands
The NUMLOCK command is one of six special CONFIG.SYS commands for
defining startup menus and multiple configurations.
This is also inaccurate. The NUMLOCK command has is unrelated to the
use of startup menus and multiple configurations. It is a valid
CONFIG.SYS command whether or not you are defining menus or multiple
configurations.
DMA Default Value Is 32
MS-DOS Help and page 209 of the "Technical Reference" state the
following in the EMM386.EXE section:
D=nnn
Specifies how many kilobytes of memory should be reserved for
buffered direct memory access (DMA). Discounting floppy-disk
DMA, this value should reflect the largest DMA transfer that
will occur while EMM386 is active. Valid values for nnn are in
the range 16 through 256. The default value is 16.
This is incorrect, the default value is 32.
"TECHNICAL REFERENCE" ERRORS
"Technical Reference" - Page 3
On page 3, the "Technical Reference" incorrectly states:
For example, if your MS-DOS files are in C:\DOS, Setup might add
the following lines to the [386Enh] section of your PROGMAN.INI:
The statement should read:
For example, if your MS-DOS files are in C:\DOS, Setup might add
the following lines to the [386Enh] section of your SYSTEM.INI:
"Technical Reference" - Page 13
The example of how DoubleSpace compresses "The rain in Spain falls mainly
on the plain," found on page 13 of the "Technical Reference," is incorrect.
The correct representation of the compressed sentence is:
The rain <3,3>Sp<9,4>falls m<11,3>ly on t<34,3>pl<15,3>.
NOTE: The difference is in the fourth offset; in the "Technical Reference"
it is shown as 37, it should be 3.
"Technical Reference": Page 14 - "A CVF Is Just a Hidden,
Read-Only File..."
On page 14 of the "Technical Reference," the second paragraph under
the section "How Does DoubleSpace Store Compressed Data on a Drive?"
begins as follows:
A CVF is just a Hidden, Read-Only file until you mount it. Mounting
a CVF establishes...
It should read as follows:
A CVF is just a Hidden, System, Read-Only file until you mount it.
Mounting a CVF establishes...
Technical Reference - Page 32
The third bit flag definition on page 32 of the "Technical Reference"
appears as follows:
micapDECOMPRESS equ 0000000000000010b ; Standard compress
It should read:
micapDECOMPRESS equ 0000000000000010b ; Standard decompress
Technical Reference - Page 177
On page 177 of the "Technical Reference," the "Examples" section
contains improper command syntax.
It incorrectly states:
device=c:\\DOS\\himem.sys
device=c:\\DOS\\emm386.exe ram
DOS=umb
It should read:
device=c:\DOS\himem.sys
device=c:\DOS\emm386.exe ram
DOS=umb
Incomplete List of Files Copied with FORMAT /S
The explanation of the FORMAT command on page 229 of the "Technical
Reference" for MS-DOS 6.0 indicates that issuing the command with the
/S switch copies the IO.SYS, MSDOS.SYS, and COMMAND.COM files from
your system startup drive to your newly formatted disk.
In addition to the files indicated, FORMAT /S copies the DBLSPACE.BIN
file to your newly formatted disk.
Incomplete List of Files Copied with SYS Command
The explanation of the SYS command on page 341 of the "Technical
Reference" for MS-DOS 6.0 indicates that issuing the command creates a
startup disk by copying the IO.SYS, MSDOS.SYS, and COMMAND.COM files
from your system startup drive to your newly formatted disk.
In addition to the files indicated, SYS copies the DBLSPACE.BIN file to
the startup disk.
Incorrect Value for SENTRY Directory
Page 347 of the "MS-DOS Technical Reference" incorrectly states:
The size of the SENTRY directory and its files is limited to
approximately 7 percent of your hard disk space.
Actually, the size of the SENTRY directory and its files is limited to
approximately 20 percent of your hard disk space (by default). Page 349
states this correctly.
Incorrect Statement Regarding VERIFY
The Verify section on page 353 of the "MS-DOS Technical Reference"
incorrectly states:
You can use VERIFY either from the command line or the CONFIG.SYS.
The correct statement is:
You can use VERIFY from the command line or the AUTOEXEC.BAT file.
MS-DOS UTILITIES ONLINE HELP ERRORS
Degrag Help: FULL OPTIMIZE with MS-DOS Defragmenter (Defrag)
MS-DOS Defragmenter (Defrag) Help incorrectly states that the FULL
OPTIMIZE option will move directories to the front of the disk.
DoubleSpace Help: Drive Letter Memory Use Is Listed Incorrectly
Under "Last drive reserved for Dblspace's use," MS-DOS DoubleSpace
Help incorrectly states the following:
Each drive letter uses 24K of memory: to conserve memory, decrease
this amount.
Actually, each drive letter uses 24 bytes of memory.
Undelete Help: Incomplete
The help topic displayed by UNFORMAT (when you use the /? parameter)
is different than the information displayed by MS-DOS Help. UNFORMAT
/? lists several switches such as /J and /PARTN that are omitted from
HELP UNFORMAT.
VSAFE Help: Incorrect VSAFE Memory Requirement
The online help for the VSAFE utility in MS-DOS 6.0 incorrectly states
that VSAFE requires approximately 22 kilobytes (K) of memory for
operation. The correct memory requirement, 44K, is stated on page 72
of the "User's Guide."
Anti-Virus Help: Incorrect Help Text
The following text in Microsoft Anti-Virus help is not relevant to
this release of Microsoft Anti-Virus:
Indexed (visible in Index):
After Microsoft Anti-Virus performs an action, a summary of that
action is recorded in the activity log. The activity log holds a
maximum of 200 entries. When this limit is reached, the oldest entry
is deleted each time a new activity is recorded.
Not-Indexed (visible only by scanning through the help windows):
The version of DOS you are using is not supported by Microsoft
Anti-Virus. Microsoft Anti-Virus requires DOS 3.3 and later.
A virus has been detected but could not be removed from the file.
Please contact Microsoft about getting an update to Microsoft
Anti-Virus to clean the file.
The virus signature you have entered is incorrect. Verify that the
data you have entered is correct. Contact Microsoft if the problem
persists.
Choose the Update Virus List command if you have information about a
new virus. The data describes the virus "signature"--the unique set of
hexadecimal characters that distinguishes it from other programs or
pieces of code.
Anti-Virus Help: Misleading Help Text for /S Switch
According to Microsoft Anti-Virus Help (MSAV /?), the /S switch scans
the disk and files for viruses and is always on by default. This is
true only when you specify more than one drive.
For example, if you type
at the MS-DOS command prompt and then press ENTER, the Microsoft
Anti-Virus interface starts.
However, if you type
at the MS-DOS command prompt and then press ENTER, the Microsoft
Anti-Virus interface starts, scans for viruses, and then returns to
the MS-DOS command prompt.
To scan only one drive from the MS-DOS command prompt (or from a
batch file), be sure to use the /S parameter.
MS Backup for Windows Help: Command-Line Syntax Error
The online help for Microsoft Backup for Windows states the following
in the Command-Line Options section:
Syntax
------
WINBACK.EXE [SETUP.SET] [/M]
This help topic should read as follows:
Syntax
------
MWBACKUP.EXE [SETUP.SET] [/M]
Interlnq Help: Pinout Chart Is Incorrect
The Pinout Chart under Notes is incorrect for 9-Pin to 9-Pin Serial
Connections. The chart states to connect pin 6 to pin 4, and pin 4 to
pin 6. If this is done, the cable does not work properly.
If you leave pin 6 blank and connect pin 4 to pin 4, the cable works
correctly.
Undelete: Incorrect Value for SENTRY Directory
The NOTES section of the Undelete online help incorrectly states:
The size of the SENTRY directory and its files is limited to
approximately 7 percent of your hard disk space.
Actually, the size of the SENTRY directory and its files is limited to
approximately 20 percent of your hard disk space (by default). Further down
in the same online help section under the "The UNDELETE.INI file" heading,
the following information is correctly stated:
- The amount of total disk space reserved for deleted files. The
following entry defines the default value:
percentage=20