Server Loses All Reference to the Session with 3C507 (99190)
The information in this article applies to:
- Microsoft LAN Manager 2.0
- Microsoft LAN Manager 2.1
- Microsoft LAN Manager 2.1a
- Microsoft LAN Manager 2.2
This article was previously published under Q99190 SUMMARY
If you have a problem with 3C507 workstations, a session will drop and
the server loses all reference to the session. Sometimes, the
workstation cannot find the server again until you re-boot the
workstation warm or cold.
To fix this problem, increase the parameters below in Protocol.ini,
and increase buffer 3C507 to 32k:
[NETBEUI_XIF]
Drivername = netbeui$
t1=4000
t2=1000
ti=60000
Pipeline=40
Adaptrate=2000
windowerrors=1
SESSIONS = 6
NCBS = 12
BINDINGS = "ELNK16_NIF"
LANABASE = 0
These settings are only for 3C507 workstations.
Modification Type: | Major | Last Reviewed: | 9/30/2003 |
---|